Post-Operative Lucency Formation Amongst Stemmed vs Non-Stemmed Total Ankle Arthroplasty Constructs
Category: Ankle Arthritis; Ankle; Hindfoot Introduction/Purpose: Current available total ankle replacement constructs offer either proximal projecting pegs (non- stemmed) in various shapes or large stem (stemmed) designs to the superior aspect of the tibia component. Each design offers inherent stab...
Main Authors: | John M. Thompson, Gregory C. Berlet MD, Cody J. Togher, Brian E. Houng, Vincent G. Vacketta |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2022-11-01
|
Series: | Foot & Ankle Orthopaedics |
Online Access: | https://doi.org/10.1177/2473011421S00972 |
Similar Items
-
Stress Shielding and Aseptic Loosening in Fully Porous-Coated vs Smooth Stemmed Tibial Implants in Total Ankle Arthroplasty
by: Cody J. Togher, et al.
Published: (2022-11-01) -
Humeral stem lucencies correlate with clinical outcomes in anatomic total shoulder arthroplasty
by: Gregory Y. LaChaud, MD, et al.
Published: (2020-09-01) -
Hounsfield Unit Assessed Bone Density Amongst Non-Traumatic and Post-Traumatic Arthritic Total Ankle Arthroplasty Patients
by: John M. Thompson, et al.
Published: (2022-11-01) -
Total ankle replacement for treatment of complex congenital fibular hemimelia
by: Cody J. Togher, DPM, AACFAS, et al.
Published: (2022-01-01) -
Fibuloplasty: Distal fibular reconstruction performed in conjunction with ankle fusion conversion to implant arthroplasty
by: Cody J. Togher, DPM, AACFAS, et al.