An evaluation of the efficacy of the locked plate with bone grafting in Sanders type III and IV intra-articular calcaneus fractures

Objective: To demonstrate the efficacy of locking plate osteosynthesis performed by an L-shaped lateral approach in patients with Sanders type III and IV intra-articular calcaneal fractures with posterior facet displacement. Methods: Fifty-three patients with Sanders type III or IV unilateral calcan...

Full description

Bibliographic Details
Main Authors: Ali Varol, Yunus Oc, Bekir Eray Kilinc
Format: Article
Language:English
Published: SAGE Publishing 2021-08-01
Series:SAGE Open Medicine
Online Access:https://doi.org/10.1177/20503121211040954
_version_ 1819133941759606784
author Ali Varol
Yunus Oc
Bekir Eray Kilinc
author_facet Ali Varol
Yunus Oc
Bekir Eray Kilinc
author_sort Ali Varol
collection DOAJ
description Objective: To demonstrate the efficacy of locking plate osteosynthesis performed by an L-shaped lateral approach in patients with Sanders type III and IV intra-articular calcaneal fractures with posterior facet displacement. Methods: Fifty-three patients with Sanders type III or IV unilateral calcaneal fractures treated with locking plates and additional bone grafting were included in the study. Böhler and Gissane angles, and heel height values were measured on the radiological examinations. Clinical results of the patients were evaluated using the American Orthopaedic Foot and Ankle Society and Maryland evaluation criteria. The presence of arthrosis was investigated with Broden’s view. Preoperative and postoperative values were evaluated. Results: The mean Gissane angle was 119.32°, the mean Böhler angle was 9.47° and the mean heel height was 40.82 mm on radiographs at initial presentation of the patients. The mean Gissane angle was 114.63°, the mean Böhler angle was 23.33° and the mean heel height was 47.84 mm on the early postoperative radiographs of the patients. In patients, a mean 4.69° recovery was achieved in the Gissane angle, 13.86° in Böhler angle and 7.02 mm in heel height. On the most recent follow-up, Böhler angle was 21.49°, Gissane was 114.88° and the mean heel height was 46.95 mm. The mean American Orthopaedic Foot and Ankle Society score and Maryland score were 86.91 and 86.53, respectively, on the last follow-up. Conclusion: Internal fixation and grephonage using low-profile locking plates provides good functional results to patients since it facilitates anatomic restoration of the subtalar joint and correction of calcaneal height, width and varus/valgus heel.
first_indexed 2024-12-22T09:55:18Z
format Article
id doaj.art-9735aa97b5834a83a6b223a4839a00b2
institution Directory Open Access Journal
issn 2050-3121
language English
last_indexed 2024-12-22T09:55:18Z
publishDate 2021-08-01
publisher SAGE Publishing
record_format Article
series SAGE Open Medicine
spelling doaj.art-9735aa97b5834a83a6b223a4839a00b22022-12-21T18:30:17ZengSAGE PublishingSAGE Open Medicine2050-31212021-08-01910.1177/20503121211040954An evaluation of the efficacy of the locked plate with bone grafting in Sanders type III and IV intra-articular calcaneus fracturesAli Varol0Yunus Oc1Bekir Eray Kilinc2Department of Orthopaedics and Traumatology, Health Science University, Istanbul Fatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyDepartment of Orthopaedics and Traumatology, Beykent University Faculty of Medicine, Istanbul, TurkeyDepartment of Orthopaedics and Traumatology, Health Science University, Istanbul Fatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyObjective: To demonstrate the efficacy of locking plate osteosynthesis performed by an L-shaped lateral approach in patients with Sanders type III and IV intra-articular calcaneal fractures with posterior facet displacement. Methods: Fifty-three patients with Sanders type III or IV unilateral calcaneal fractures treated with locking plates and additional bone grafting were included in the study. Böhler and Gissane angles, and heel height values were measured on the radiological examinations. Clinical results of the patients were evaluated using the American Orthopaedic Foot and Ankle Society and Maryland evaluation criteria. The presence of arthrosis was investigated with Broden’s view. Preoperative and postoperative values were evaluated. Results: The mean Gissane angle was 119.32°, the mean Böhler angle was 9.47° and the mean heel height was 40.82 mm on radiographs at initial presentation of the patients. The mean Gissane angle was 114.63°, the mean Böhler angle was 23.33° and the mean heel height was 47.84 mm on the early postoperative radiographs of the patients. In patients, a mean 4.69° recovery was achieved in the Gissane angle, 13.86° in Böhler angle and 7.02 mm in heel height. On the most recent follow-up, Böhler angle was 21.49°, Gissane was 114.88° and the mean heel height was 46.95 mm. The mean American Orthopaedic Foot and Ankle Society score and Maryland score were 86.91 and 86.53, respectively, on the last follow-up. Conclusion: Internal fixation and grephonage using low-profile locking plates provides good functional results to patients since it facilitates anatomic restoration of the subtalar joint and correction of calcaneal height, width and varus/valgus heel.https://doi.org/10.1177/20503121211040954
spellingShingle Ali Varol
Yunus Oc
Bekir Eray Kilinc
An evaluation of the efficacy of the locked plate with bone grafting in Sanders type III and IV intra-articular calcaneus fractures
SAGE Open Medicine
title An evaluation of the efficacy of the locked plate with bone grafting in Sanders type III and IV intra-articular calcaneus fractures
title_full An evaluation of the efficacy of the locked plate with bone grafting in Sanders type III and IV intra-articular calcaneus fractures
title_fullStr An evaluation of the efficacy of the locked plate with bone grafting in Sanders type III and IV intra-articular calcaneus fractures
title_full_unstemmed An evaluation of the efficacy of the locked plate with bone grafting in Sanders type III and IV intra-articular calcaneus fractures
title_short An evaluation of the efficacy of the locked plate with bone grafting in Sanders type III and IV intra-articular calcaneus fractures
title_sort evaluation of the efficacy of the locked plate with bone grafting in sanders type iii and iv intra articular calcaneus fractures
url https://doi.org/10.1177/20503121211040954
work_keys_str_mv AT alivarol anevaluationoftheefficacyofthelockedplatewithbonegraftinginsanderstypeiiiandivintraarticularcalcaneusfractures
AT yunusoc anevaluationoftheefficacyofthelockedplatewithbonegraftinginsanderstypeiiiandivintraarticularcalcaneusfractures
AT bekireraykilinc anevaluationoftheefficacyofthelockedplatewithbonegraftinginsanderstypeiiiandivintraarticularcalcaneusfractures
AT alivarol evaluationoftheefficacyofthelockedplatewithbonegraftinginsanderstypeiiiandivintraarticularcalcaneusfractures
AT yunusoc evaluationoftheefficacyofthelockedplatewithbonegraftinginsanderstypeiiiandivintraarticularcalcaneusfractures
AT bekireraykilinc evaluationoftheefficacyofthelockedplatewithbonegraftinginsanderstypeiiiandivintraarticularcalcaneusfractures