Preliminary measurements of T-T90 using acoustic gas thermometer in neon gas

The measurements of the difference between the thermodynamic temperature T and the temperature T90 based on the International Temperature Scale of 1990 (ITS-90), (T-T90), by using an acoustic gas thermometer (AGT) working on neon gas is reported in this paper. The AGT introduced a one-liter quasi-sp...

Full description

Bibliographic Details
Main Authors: J.V. Widiatmo, T. Misawa, T. Nakano, I. Saito
Format: Article
Language:English
Published: Elsevier 2021-12-01
Series:Measurement: Sensors
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2665917421001549
_version_ 1818717226575855616
author J.V. Widiatmo
T. Misawa
T. Nakano
I. Saito
author_facet J.V. Widiatmo
T. Misawa
T. Nakano
I. Saito
author_sort J.V. Widiatmo
collection DOAJ
description The measurements of the difference between the thermodynamic temperature T and the temperature T90 based on the International Temperature Scale of 1990 (ITS-90), (T-T90), by using an acoustic gas thermometer (AGT) working on neon gas is reported in this paper. The AGT introduced a one-liter quasi-spherical resonator made of oxygen-free-copper. The thermodynamic temperature was determined relatively from the speed of sound measurements at a desired temperature regarding to those at the triple point of water. At the present stage, the aimed temperature range was the gallium melting point. Based on the obtained measured speed of sound, the thermodynamic temperature T and the values of (T-T90) were determined, and the associated uncertainties were estimated. The (T-T90) obtained in the present work was found to agree within the estimated uncertainty with the currently reported values that exist in temperature range overlapping with the present work.
first_indexed 2024-12-17T19:31:47Z
format Article
id doaj.art-9774d5e4431c4a2a8667ee0cf55b0dd6
institution Directory Open Access Journal
issn 2665-9174
language English
last_indexed 2024-12-17T19:31:47Z
publishDate 2021-12-01
publisher Elsevier
record_format Article
series Measurement: Sensors
spelling doaj.art-9774d5e4431c4a2a8667ee0cf55b0dd62022-12-21T21:35:15ZengElsevierMeasurement: Sensors2665-91742021-12-0118100191Preliminary measurements of T-T90 using acoustic gas thermometer in neon gasJ.V. Widiatmo0T. Misawa1T. Nakano2I. Saito3Corresponding author.; National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, JapanNational Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, JapanNational Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, JapanNational Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, JapanThe measurements of the difference between the thermodynamic temperature T and the temperature T90 based on the International Temperature Scale of 1990 (ITS-90), (T-T90), by using an acoustic gas thermometer (AGT) working on neon gas is reported in this paper. The AGT introduced a one-liter quasi-spherical resonator made of oxygen-free-copper. The thermodynamic temperature was determined relatively from the speed of sound measurements at a desired temperature regarding to those at the triple point of water. At the present stage, the aimed temperature range was the gallium melting point. Based on the obtained measured speed of sound, the thermodynamic temperature T and the values of (T-T90) were determined, and the associated uncertainties were estimated. The (T-T90) obtained in the present work was found to agree within the estimated uncertainty with the currently reported values that exist in temperature range overlapping with the present work.http://www.sciencedirect.com/science/article/pii/S2665917421001549Acoustic gas thermometryAcoustic resonanceMicrowave resonancePrimary thermometry
spellingShingle J.V. Widiatmo
T. Misawa
T. Nakano
I. Saito
Preliminary measurements of T-T90 using acoustic gas thermometer in neon gas
Measurement: Sensors
Acoustic gas thermometry
Acoustic resonance
Microwave resonance
Primary thermometry
title Preliminary measurements of T-T90 using acoustic gas thermometer in neon gas
title_full Preliminary measurements of T-T90 using acoustic gas thermometer in neon gas
title_fullStr Preliminary measurements of T-T90 using acoustic gas thermometer in neon gas
title_full_unstemmed Preliminary measurements of T-T90 using acoustic gas thermometer in neon gas
title_short Preliminary measurements of T-T90 using acoustic gas thermometer in neon gas
title_sort preliminary measurements of t t90 using acoustic gas thermometer in neon gas
topic Acoustic gas thermometry
Acoustic resonance
Microwave resonance
Primary thermometry
url http://www.sciencedirect.com/science/article/pii/S2665917421001549
work_keys_str_mv AT jvwidiatmo preliminarymeasurementsoftt90usingacousticgasthermometerinneongas
AT tmisawa preliminarymeasurementsoftt90usingacousticgasthermometerinneongas
AT tnakano preliminarymeasurementsoftt90usingacousticgasthermometerinneongas
AT isaito preliminarymeasurementsoftt90usingacousticgasthermometerinneongas