A new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)

Abstract Visual field (VF) test is one of the most vital tests in the diagnosis of glaucoma and to monitor the disease worsening. In the past couple of decades, the standard automated perimetry (SAP) test takes a major role in VF test for glaucoma patients. The SAP has been demanded to finish a test...

Full description

Bibliographic Details
Main Authors: Hiroki Nomoto, Chota Matsumoto, Sachiko Okuyama, Shinji Kimura, Satoshi Inoue, Kenzo Yamanaka, Shunji Kusaka
Format: Article
Language:English
Published: Nature Portfolio 2023-09-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-023-42266-z
_version_ 1827711176851587072
author Hiroki Nomoto
Chota Matsumoto
Sachiko Okuyama
Shinji Kimura
Satoshi Inoue
Kenzo Yamanaka
Shunji Kusaka
author_facet Hiroki Nomoto
Chota Matsumoto
Sachiko Okuyama
Shinji Kimura
Satoshi Inoue
Kenzo Yamanaka
Shunji Kusaka
author_sort Hiroki Nomoto
collection DOAJ
description Abstract Visual field (VF) test is one of the most vital tests in the diagnosis of glaucoma and to monitor the disease worsening. In the past couple of decades, the standard automated perimetry (SAP) test takes a major role in VF test for glaucoma patients. The SAP has been demanded to finish a test in short time without sacrificing accuracy. In this study, we developed and evaluated the performance of a new perimetric algorithm (ambient interactive zippy estimation by sequential testing (ZEST): AIZE) by computer simulation. AIZE is a modification of the ZEST procedure that utilizes the spatial information (weighted likelihood: WL) of neighboring test locations, which varies from the distance to the tested location, to estimate a visual threshold. Ten glaucomatous and 10 normal empirical visual field (VF) test results were simulated with five error conditions [(3% false positives (FP), 3% false negatives (FN)), (9% FP, 9% FN), (15% FP, 15% FN), (3% FP, 15% FN), (15% FP, 3% FN)]. The total number of test presentations and the root mean square error (RMSE) of the estimated visual sensitivities were compared among AIZE, the non-weighted test (WL = 0) and the fixed-weighted test (WL = 0.33). In both glaucomatous (G) and normal (N) VFs, the fixed-weighted test had the lowest number of test presentations (median G 256, N 139), followed by the AIZE (G 285, N 174) and the non-weighted test (G 303, N 195). The RMSE of the fixed-weighted test was lower (median 1.7 dB) than that of the AIZE (1.9 dB) and the non-weighted test (1.9 dB) for normal VFs, whereas the AIZE had a lower RMSE (3.2 dB) than the fixed-weighted test (4.5 dB) and the non-weighted test (4.0 dB) for glaucomatous VFs. Simulation results showed that AIZE had fewer test presentations than the non-weighted test strategy without affecting the accuracy for glaucomatous VFs. The AIZE is a useful time saving test algorithm in clinical settings.
first_indexed 2024-03-10T17:51:04Z
format Article
id doaj.art-979f7101380e4ad1b7c6de72b42393b9
institution Directory Open Access Journal
issn 2045-2322
language English
last_indexed 2024-03-10T17:51:04Z
publishDate 2023-09-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj.art-979f7101380e4ad1b7c6de72b42393b92023-11-20T09:22:02ZengNature PortfolioScientific Reports2045-23222023-09-011311810.1038/s41598-023-42266-zA new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)Hiroki Nomoto0Chota Matsumoto1Sachiko Okuyama2Shinji Kimura3Satoshi Inoue4Kenzo Yamanaka5Shunji Kusaka6Department of Ophthalmology, Faculty of Medicine, Kindai UniversityDepartment of Ophthalmology, Faculty of Medicine, Kindai UniversityDepartment of Ophthalmology, Faculty of Medicine, Kindai UniversityCREWT Medical Systems Inc.CREWT Medical Systems Inc.CREWT Medical Systems Inc.Department of Ophthalmology, Faculty of Medicine, Kindai UniversityAbstract Visual field (VF) test is one of the most vital tests in the diagnosis of glaucoma and to monitor the disease worsening. In the past couple of decades, the standard automated perimetry (SAP) test takes a major role in VF test for glaucoma patients. The SAP has been demanded to finish a test in short time without sacrificing accuracy. In this study, we developed and evaluated the performance of a new perimetric algorithm (ambient interactive zippy estimation by sequential testing (ZEST): AIZE) by computer simulation. AIZE is a modification of the ZEST procedure that utilizes the spatial information (weighted likelihood: WL) of neighboring test locations, which varies from the distance to the tested location, to estimate a visual threshold. Ten glaucomatous and 10 normal empirical visual field (VF) test results were simulated with five error conditions [(3% false positives (FP), 3% false negatives (FN)), (9% FP, 9% FN), (15% FP, 15% FN), (3% FP, 15% FN), (15% FP, 3% FN)]. The total number of test presentations and the root mean square error (RMSE) of the estimated visual sensitivities were compared among AIZE, the non-weighted test (WL = 0) and the fixed-weighted test (WL = 0.33). In both glaucomatous (G) and normal (N) VFs, the fixed-weighted test had the lowest number of test presentations (median G 256, N 139), followed by the AIZE (G 285, N 174) and the non-weighted test (G 303, N 195). The RMSE of the fixed-weighted test was lower (median 1.7 dB) than that of the AIZE (1.9 dB) and the non-weighted test (1.9 dB) for normal VFs, whereas the AIZE had a lower RMSE (3.2 dB) than the fixed-weighted test (4.5 dB) and the non-weighted test (4.0 dB) for glaucomatous VFs. Simulation results showed that AIZE had fewer test presentations than the non-weighted test strategy without affecting the accuracy for glaucomatous VFs. The AIZE is a useful time saving test algorithm in clinical settings.https://doi.org/10.1038/s41598-023-42266-z
spellingShingle Hiroki Nomoto
Chota Matsumoto
Sachiko Okuyama
Shinji Kimura
Satoshi Inoue
Kenzo Yamanaka
Shunji Kusaka
A new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)
Scientific Reports
title A new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)
title_full A new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)
title_fullStr A new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)
title_full_unstemmed A new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)
title_short A new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)
title_sort new static visual field test algorithm the ambient interactive zest aize
url https://doi.org/10.1038/s41598-023-42266-z
work_keys_str_mv AT hirokinomoto anewstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT chotamatsumoto anewstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT sachikookuyama anewstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT shinjikimura anewstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT satoshiinoue anewstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT kenzoyamanaka anewstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT shunjikusaka anewstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT hirokinomoto newstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT chotamatsumoto newstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT sachikookuyama newstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT shinjikimura newstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT satoshiinoue newstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT kenzoyamanaka newstaticvisualfieldtestalgorithmtheambientinteractivezestaize
AT shunjikusaka newstaticvisualfieldtestalgorithmtheambientinteractivezestaize