Effect of Increased Cabin Recirculation Airflow Fraction on Relative Humidity, CO<sub>2</sub> and TVOC

In the CleanSky 2 ComAir study, subject tests were conducted in the Fraunhofer Flight Test Facility cabin mock-up. This mock-up consists of the front section of a former in-service A310 hosting up to 80 passengers. In 12 sessions the outdoor/recirculation airflow ratio was altered from today’s typic...

Full description

Bibliographic Details
Main Authors: Victor Norrefeldt, Florian Mayer, Britta Herbig, Ria Ströhlein, Pawel Wargocki, Fang Lei
Format: Article
Language:English
Published: MDPI AG 2021-01-01
Series:Aerospace
Subjects:
Online Access:https://www.mdpi.com/2226-4310/8/1/15
_version_ 1797412108968656896
author Victor Norrefeldt
Florian Mayer
Britta Herbig
Ria Ströhlein
Pawel Wargocki
Fang Lei
author_facet Victor Norrefeldt
Florian Mayer
Britta Herbig
Ria Ströhlein
Pawel Wargocki
Fang Lei
author_sort Victor Norrefeldt
collection DOAJ
description In the CleanSky 2 ComAir study, subject tests were conducted in the Fraunhofer Flight Test Facility cabin mock-up. This mock-up consists of the front section of a former in-service A310 hosting up to 80 passengers. In 12 sessions the outdoor/recirculation airflow ratio was altered from today’s typically applied fractions to up to 88% recirculation fraction. This leads to increased relative humidity, carbon dioxide (CO<sub>2</sub>) and Total Volatile Organic Compounds (TVOC) levels in the cabin air, as the emissions by passengers become less diluted by outdoor, dry air. This paper describes the measured increase of relative humidity, CO<sub>2</sub> and TVOC level in the cabin air for the different test conditions.
first_indexed 2024-03-09T04:57:19Z
format Article
id doaj.art-97ae01f548734dd498385e95a4317a3e
institution Directory Open Access Journal
issn 2226-4310
language English
last_indexed 2024-03-09T04:57:19Z
publishDate 2021-01-01
publisher MDPI AG
record_format Article
series Aerospace
spelling doaj.art-97ae01f548734dd498385e95a4317a3e2023-12-03T13:04:08ZengMDPI AGAerospace2226-43102021-01-01811510.3390/aerospace8010015Effect of Increased Cabin Recirculation Airflow Fraction on Relative Humidity, CO<sub>2</sub> and TVOCVictor Norrefeldt0Florian Mayer1Britta Herbig2Ria Ströhlein3Pawel Wargocki4Fang Lei5Fraunhofer Institute for Building Physics IBP, 83626 Valley, GermanyFraunhofer Institute for Building Physics IBP, 83626 Valley, GermanyInstitute and Clinic for Occupational, Social and Environmental Medicine, LMU University Hospital Munich, 80336 Munich, GermanyInstitute and Clinic for Occupational, Social and Environmental Medicine, LMU University Hospital Munich, 80336 Munich, GermanyDepartment of Civil Engineering, Technical University of Denmark, 2800 Kgs. Lyngby, DenmarkDepartment of Civil Engineering, Technical University of Denmark, 2800 Kgs. Lyngby, DenmarkIn the CleanSky 2 ComAir study, subject tests were conducted in the Fraunhofer Flight Test Facility cabin mock-up. This mock-up consists of the front section of a former in-service A310 hosting up to 80 passengers. In 12 sessions the outdoor/recirculation airflow ratio was altered from today’s typically applied fractions to up to 88% recirculation fraction. This leads to increased relative humidity, carbon dioxide (CO<sub>2</sub>) and Total Volatile Organic Compounds (TVOC) levels in the cabin air, as the emissions by passengers become less diluted by outdoor, dry air. This paper describes the measured increase of relative humidity, CO<sub>2</sub> and TVOC level in the cabin air for the different test conditions.https://www.mdpi.com/2226-4310/8/1/15aircraft air qualityadaptive ECSsubject testing
spellingShingle Victor Norrefeldt
Florian Mayer
Britta Herbig
Ria Ströhlein
Pawel Wargocki
Fang Lei
Effect of Increased Cabin Recirculation Airflow Fraction on Relative Humidity, CO<sub>2</sub> and TVOC
Aerospace
aircraft air quality
adaptive ECS
subject testing
title Effect of Increased Cabin Recirculation Airflow Fraction on Relative Humidity, CO<sub>2</sub> and TVOC
title_full Effect of Increased Cabin Recirculation Airflow Fraction on Relative Humidity, CO<sub>2</sub> and TVOC
title_fullStr Effect of Increased Cabin Recirculation Airflow Fraction on Relative Humidity, CO<sub>2</sub> and TVOC
title_full_unstemmed Effect of Increased Cabin Recirculation Airflow Fraction on Relative Humidity, CO<sub>2</sub> and TVOC
title_short Effect of Increased Cabin Recirculation Airflow Fraction on Relative Humidity, CO<sub>2</sub> and TVOC
title_sort effect of increased cabin recirculation airflow fraction on relative humidity co sub 2 sub and tvoc
topic aircraft air quality
adaptive ECS
subject testing
url https://www.mdpi.com/2226-4310/8/1/15
work_keys_str_mv AT victornorrefeldt effectofincreasedcabinrecirculationairflowfractiononrelativehumiditycosub2subandtvoc
AT florianmayer effectofincreasedcabinrecirculationairflowfractiononrelativehumiditycosub2subandtvoc
AT brittaherbig effectofincreasedcabinrecirculationairflowfractiononrelativehumiditycosub2subandtvoc
AT riastrohlein effectofincreasedcabinrecirculationairflowfractiononrelativehumiditycosub2subandtvoc
AT pawelwargocki effectofincreasedcabinrecirculationairflowfractiononrelativehumiditycosub2subandtvoc
AT fanglei effectofincreasedcabinrecirculationairflowfractiononrelativehumiditycosub2subandtvoc