SIMULTANEOUS DETERMINATION OF FLUORIDE, ACETATE, FORMATE, CHLORIDE, NITRATE, AND SULFATE IN DISTILLED ALCOHOLIC BEVERAGES WITH ION CHROMATOGRAPHY/CONDUCTIVITY DETECTOR

A novel ion chromatography with suppressed conductivity detection method was developed for simultaneous determination of fluoride, acetate, formate, chloride, nitrate, and sulphate in distilled alcoholic beverages. In this study, bromide was used as an internal standard. The separation of the anions...

Full description

Bibliographic Details
Main Authors: Melike Güler Şimşek, Orhan Destanoğlu, Gülçin Gümüş Yılmaz
Format: Article
Language:English
Published: Turkish Chemical Society 2020-10-01
Series:Journal of the Turkish Chemical Society, Section A: Chemistry
Subjects:
Online Access:https://dergipark.org.tr/tr/pub/jotcsa/issue/55312/700636
_version_ 1797914166255681536
author Melike Güler Şimşek
Orhan Destanoğlu
Gülçin Gümüş Yılmaz
author_facet Melike Güler Şimşek
Orhan Destanoğlu
Gülçin Gümüş Yılmaz
author_sort Melike Güler Şimşek
collection DOAJ
description A novel ion chromatography with suppressed conductivity detection method was developed for simultaneous determination of fluoride, acetate, formate, chloride, nitrate, and sulphate in distilled alcoholic beverages. In this study, bromide was used as an internal standard. The separation of the anions was accomplished by utilising an anion exchange column with gradient eluent program. The chromatographic conditions were as follows: the suppressor current was 31 mA; the flow rate of the mobile phase was 0.25 mL min-1; the column and detector compartment temperature were 35 °C and 40 °C, respectively; sample loop volume was 10 μL. All the calibration curves showed good linearity (r2 ≥ 0.999). The limits of detection (LOD) values were between 0.56 and 13.2 μg L-1 while the limits of quantification (LOQ) values were between 1.80 and 43.9 μg L-1. To evaluate the accuracy, a raki sample was spiked with standard solutions at three different concentration levels and the average recoveries were found in the range of 94.90% - 101.71%. Intra-day and inter-day precision studies were also investigated and the relative standard deviations (RSDs %) were less than 5.99%. The validated method was applied to the three kinds of commercial samples: Turkish raki, vodka, and gin.
first_indexed 2024-04-10T12:22:20Z
format Article
id doaj.art-97ccab5ac5884b1193c7b13149a622cf
institution Directory Open Access Journal
issn 2149-0120
language English
last_indexed 2024-04-10T12:22:20Z
publishDate 2020-10-01
publisher Turkish Chemical Society
record_format Article
series Journal of the Turkish Chemical Society, Section A: Chemistry
spelling doaj.art-97ccab5ac5884b1193c7b13149a622cf2023-02-15T16:15:24ZengTurkish Chemical SocietyJournal of the Turkish Chemical Society, Section A: Chemistry2149-01202020-10-017366167410.18596/jotcsa.700636SIMULTANEOUS DETERMINATION OF FLUORIDE, ACETATE, FORMATE, CHLORIDE, NITRATE, AND SULFATE IN DISTILLED ALCOHOLIC BEVERAGES WITH ION CHROMATOGRAPHY/CONDUCTIVITY DETECTORMelike Güler Şimşek0https://orcid.org/0000-0003-4848-4342Orhan Destanoğlu1https://orcid.org/0000-0003-2477-0694Gülçin Gümüş Yılmaz2https://orcid.org/0000-0002-5627-0814Istanbul Technical UniversityAdli Tıp Kurumu BaşkanlığıIstanbul Technical UniversityA novel ion chromatography with suppressed conductivity detection method was developed for simultaneous determination of fluoride, acetate, formate, chloride, nitrate, and sulphate in distilled alcoholic beverages. In this study, bromide was used as an internal standard. The separation of the anions was accomplished by utilising an anion exchange column with gradient eluent program. The chromatographic conditions were as follows: the suppressor current was 31 mA; the flow rate of the mobile phase was 0.25 mL min-1; the column and detector compartment temperature were 35 °C and 40 °C, respectively; sample loop volume was 10 μL. All the calibration curves showed good linearity (r2 ≥ 0.999). The limits of detection (LOD) values were between 0.56 and 13.2 μg L-1 while the limits of quantification (LOQ) values were between 1.80 and 43.9 μg L-1. To evaluate the accuracy, a raki sample was spiked with standard solutions at three different concentration levels and the average recoveries were found in the range of 94.90% - 101.71%. Intra-day and inter-day precision studies were also investigated and the relative standard deviations (RSDs %) were less than 5.99%. The validated method was applied to the three kinds of commercial samples: Turkish raki, vodka, and gin.https://dergipark.org.tr/tr/pub/jotcsa/issue/55312/700636ion chromatographyanion analysisdistilled alcoholic beverages
spellingShingle Melike Güler Şimşek
Orhan Destanoğlu
Gülçin Gümüş Yılmaz
SIMULTANEOUS DETERMINATION OF FLUORIDE, ACETATE, FORMATE, CHLORIDE, NITRATE, AND SULFATE IN DISTILLED ALCOHOLIC BEVERAGES WITH ION CHROMATOGRAPHY/CONDUCTIVITY DETECTOR
Journal of the Turkish Chemical Society, Section A: Chemistry
ion chromatography
anion analysis
distilled alcoholic beverages
title SIMULTANEOUS DETERMINATION OF FLUORIDE, ACETATE, FORMATE, CHLORIDE, NITRATE, AND SULFATE IN DISTILLED ALCOHOLIC BEVERAGES WITH ION CHROMATOGRAPHY/CONDUCTIVITY DETECTOR
title_full SIMULTANEOUS DETERMINATION OF FLUORIDE, ACETATE, FORMATE, CHLORIDE, NITRATE, AND SULFATE IN DISTILLED ALCOHOLIC BEVERAGES WITH ION CHROMATOGRAPHY/CONDUCTIVITY DETECTOR
title_fullStr SIMULTANEOUS DETERMINATION OF FLUORIDE, ACETATE, FORMATE, CHLORIDE, NITRATE, AND SULFATE IN DISTILLED ALCOHOLIC BEVERAGES WITH ION CHROMATOGRAPHY/CONDUCTIVITY DETECTOR
title_full_unstemmed SIMULTANEOUS DETERMINATION OF FLUORIDE, ACETATE, FORMATE, CHLORIDE, NITRATE, AND SULFATE IN DISTILLED ALCOHOLIC BEVERAGES WITH ION CHROMATOGRAPHY/CONDUCTIVITY DETECTOR
title_short SIMULTANEOUS DETERMINATION OF FLUORIDE, ACETATE, FORMATE, CHLORIDE, NITRATE, AND SULFATE IN DISTILLED ALCOHOLIC BEVERAGES WITH ION CHROMATOGRAPHY/CONDUCTIVITY DETECTOR
title_sort simultaneous determination of fluoride acetate formate chloride nitrate and sulfate in distilled alcoholic beverages with ion chromatography conductivity detector
topic ion chromatography
anion analysis
distilled alcoholic beverages
url https://dergipark.org.tr/tr/pub/jotcsa/issue/55312/700636
work_keys_str_mv AT melikegulersimsek simultaneousdeterminationoffluorideacetateformatechloridenitrateandsulfateindistilledalcoholicbeverageswithionchromatographyconductivitydetector
AT orhandestanoglu simultaneousdeterminationoffluorideacetateformatechloridenitrateandsulfateindistilledalcoholicbeverageswithionchromatographyconductivitydetector
AT gulcingumusyılmaz simultaneousdeterminationoffluorideacetateformatechloridenitrateandsulfateindistilledalcoholicbeverageswithionchromatographyconductivitydetector