Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping
OBJECTIVES: Few studies have evaluated cardiac electrical activation dynamics after cardiac resynchronization therapy. Although this procedure reduces morbidity and mortality in heart failure patients, many approaches attempting to identify the responders have shown that 30% of patients do not attai...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier España
2013-07-01
|
Series: | Clinics |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1807-59322013000700986&lng=en&tlng=en |
_version_ | 1811317100921225216 |
---|---|
author | Nelson Samesima Carlos Alberto Pastore Roberto Andrés Douglas Martino Martinelli Filho Anísio A. Pedrosa |
author_facet | Nelson Samesima Carlos Alberto Pastore Roberto Andrés Douglas Martino Martinelli Filho Anísio A. Pedrosa |
author_sort | Nelson Samesima |
collection | DOAJ |
description | OBJECTIVES: Few studies have evaluated cardiac electrical activation dynamics after cardiac resynchronization therapy. Although this procedure reduces morbidity and mortality in heart failure patients, many approaches attempting to identify the responders have shown that 30% of patients do not attain clinical or functional improvement. This study sought to quantify and characterize the effect of resynchronization therapy on the ventricular electrical activation of patients using body surface potential mapping, a noninvasive tool. METHODS: This retrospective study included 91 resynchronization patients with a mean age of 61 years, left ventricle ejection fraction of 28%, mean QRS duration of 182 ms, and functional class III/IV (78%/22%); the patients underwent 87-lead body surface mapping with the resynchronization device on and off. Thirty-six patients were excluded. Body surface isochronal maps produced 87 maximal/mean global ventricular activation times with three regions identified. The regional activation times for right and left ventricles and their inter-regional right-to-left ventricle gradients were calculated from these results and analyzed. The Mann-Whitney U-test and Kruskall-Wallis test were used for comparisons, with the level of significance set at p≤0.05. RESULTS: During intrinsic rhythms, regional ventricular activation times were significantly different (54.5 ms vs. 95.9 ms in the right and left ventricle regions, respectively). Regarding cardiac resynchronization, the maximal global value was significantly reduced (138 ms to 131 ms), and a downward variation of 19.4% in regional-left and an upward variation of 44.8% in regional-right ventricular activation times resulted in a significantly reduced inter-regional gradient (43.8 ms to 17 ms). CONCLUSIONS: Body surface potential mapping in resynchronization patients yielded electrical ventricular activation times for two cardiac regions with significantly decreased global and regional-left values but significantly increased regional-right values, thus showing an attenuated inter-regional gradient after the cardiac resynchronization therapy. |
first_indexed | 2024-04-13T12:00:41Z |
format | Article |
id | doaj.art-97d276ddd0624cc5a54e70d92ad5c26f |
institution | Directory Open Access Journal |
issn | 1980-5322 |
language | English |
last_indexed | 2024-04-13T12:00:41Z |
publishDate | 2013-07-01 |
publisher | Elsevier España |
record_format | Article |
series | Clinics |
spelling | doaj.art-97d276ddd0624cc5a54e70d92ad5c26f2022-12-22T02:47:47ZengElsevier EspañaClinics1980-53222013-07-0168798699110.6061/clinics/2013(07)16S1807-59322013000700986Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mappingNelson SamesimaCarlos Alberto PastoreRoberto Andrés DouglasMartino Martinelli FilhoAnísio A. PedrosaOBJECTIVES: Few studies have evaluated cardiac electrical activation dynamics after cardiac resynchronization therapy. Although this procedure reduces morbidity and mortality in heart failure patients, many approaches attempting to identify the responders have shown that 30% of patients do not attain clinical or functional improvement. This study sought to quantify and characterize the effect of resynchronization therapy on the ventricular electrical activation of patients using body surface potential mapping, a noninvasive tool. METHODS: This retrospective study included 91 resynchronization patients with a mean age of 61 years, left ventricle ejection fraction of 28%, mean QRS duration of 182 ms, and functional class III/IV (78%/22%); the patients underwent 87-lead body surface mapping with the resynchronization device on and off. Thirty-six patients were excluded. Body surface isochronal maps produced 87 maximal/mean global ventricular activation times with three regions identified. The regional activation times for right and left ventricles and their inter-regional right-to-left ventricle gradients were calculated from these results and analyzed. The Mann-Whitney U-test and Kruskall-Wallis test were used for comparisons, with the level of significance set at p≤0.05. RESULTS: During intrinsic rhythms, regional ventricular activation times were significantly different (54.5 ms vs. 95.9 ms in the right and left ventricle regions, respectively). Regarding cardiac resynchronization, the maximal global value was significantly reduced (138 ms to 131 ms), and a downward variation of 19.4% in regional-left and an upward variation of 44.8% in regional-right ventricular activation times resulted in a significantly reduced inter-regional gradient (43.8 ms to 17 ms). CONCLUSIONS: Body surface potential mapping in resynchronization patients yielded electrical ventricular activation times for two cardiac regions with significantly decreased global and regional-left values but significantly increased regional-right values, thus showing an attenuated inter-regional gradient after the cardiac resynchronization therapy.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1807-59322013000700986&lng=en&tlng=enElectrocardiographyCardiac Resynchronization TherapyBody Surface Potential MappingHeart FailureBundle-Branch BlockVentricular Activation Time |
spellingShingle | Nelson Samesima Carlos Alberto Pastore Roberto Andrés Douglas Martino Martinelli Filho Anísio A. Pedrosa Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping Clinics Electrocardiography Cardiac Resynchronization Therapy Body Surface Potential Mapping Heart Failure Bundle-Branch Block Ventricular Activation Time |
title | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_full | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_fullStr | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_full_unstemmed | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_short | Improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
title_sort | improved relationship between left and right ventricular electrical activation after cardiac resynchronization therapy in heart failure patients can be quantified by body surface potential mapping |
topic | Electrocardiography Cardiac Resynchronization Therapy Body Surface Potential Mapping Heart Failure Bundle-Branch Block Ventricular Activation Time |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1807-59322013000700986&lng=en&tlng=en |
work_keys_str_mv | AT nelsonsamesima improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping AT carlosalbertopastore improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping AT robertoandresdouglas improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping AT martinomartinellifilho improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping AT anisioapedrosa improvedrelationshipbetweenleftandrightventricularelectricalactivationaftercardiacresynchronizationtherapyinheartfailurepatientscanbequantifiedbybodysurfacepotentialmapping |