Fluorescent diagnostics with chlorin e6 in surgery of low-grade glioma

Intraoperative fluorescence diagnostics of high-grade gliomas is widely used in neurosurgical practice. This work analyzes the possibilities of fluorescence diagnostics for low-grade gliomas (LGG) using chlorin e6 photosensitizer. The study included patients with newly diagnosed LGG, for whom chlori...

Full description

Bibliographic Details
Main Authors: A. Yu. Rynda, V. E. Olyushin, D. M. Rostovtsev, Y. M. Zabrodskaya, G. V. Papayan
Format: Article
Language:Russian
Published: Non-profit partnership for development of domestic photodynamic therapy and photodiagnosis "Russian Photodynamic Association" 2022-02-01
Series:Biomedical Photonics
Subjects:
Online Access:https://www.pdt-journal.com/jour/article/view/516
_version_ 1797883649015676928
author A. Yu. Rynda
V. E. Olyushin
D. M. Rostovtsev
Y. M. Zabrodskaya
G. V. Papayan
author_facet A. Yu. Rynda
V. E. Olyushin
D. M. Rostovtsev
Y. M. Zabrodskaya
G. V. Papayan
author_sort A. Yu. Rynda
collection DOAJ
description Intraoperative fluorescence diagnostics of high-grade gliomas is widely used in neurosurgical practice. This work analyzes the possibilities of fluorescence diagnostics for low-grade gliomas (LGG) using chlorin e6 photosensitizer. The study included patients with newly diagnosed LGG, for whom chlorin e6 was used for intraoperative fluorescence control at a dose of 1 mg/kg. During the operation, the fluorescence intensity of various areas of the putative tumor tissue was analyzed using the RSS Cam – Endo 1.4.313 software. Tissue samples with various degrees of fluorescence intensity were compared with the results of their histopathological analysis (WHO tumor diagnosis, Ki-67 index, P53, VEGF). Fluorescence was detected in more than half of the cases, but in most cases had a focal character and low fluorescence intensity. The fluorescence intensity directly correlated with the data of histopathological examination of tumor tissues (Ki-67 index (p=0.002), expression of P53 (p=0.0015) and VEGF (p=0.001)). The sensitivity of the method for LGG surgery was 72%, the specificity was 56,7%. Intraoperative fluorescence diagnostics with chlorin e6 can be used in LGG surgery, especially to visualize intratumoral areas with a higher degree of anaplasia.
first_indexed 2024-04-10T03:55:10Z
format Article
id doaj.art-9806d730b9ef486983bf7e7640d69826
institution Directory Open Access Journal
issn 2413-9432
language Russian
last_indexed 2024-04-10T03:55:10Z
publishDate 2022-02-01
publisher Non-profit partnership for development of domestic photodynamic therapy and photodiagnosis "Russian Photodynamic Association"
record_format Article
series Biomedical Photonics
spelling doaj.art-9806d730b9ef486983bf7e7640d698262023-03-13T07:12:31ZrusNon-profit partnership for development of domestic photodynamic therapy and photodiagnosis "Russian Photodynamic Association"Biomedical Photonics2413-94322022-02-01104354310.24931/2413-9432-2021-10-4-35-43241Fluorescent diagnostics with chlorin e6 in surgery of low-grade gliomaA. Yu. Rynda0V. E. Olyushin1D. M. Rostovtsev2Y. M. Zabrodskaya3G. V. Papayan4Российский нейрохирургический институт имени профессора А.Л. Поленова – филиал ФГБУ «Национальный медицинский исследовательский центр имени В.А. Алмазова»Российский нейрохирургический институт имени профессора А.Л. Поленова – филиал ФГБУ «Национальный медицинский исследовательский центр имени В.А. Алмазова»Российский нейрохирургический институт имени профессора А.Л. Поленова – филиал ФГБУ «Национальный медицинский исследовательский центр имени В.А. Алмазова»Российский нейрохирургический институт имени профессора А.Л. Поленова – филиал ФГБУ «Национальный медицинский исследовательский центр имени В.А. Алмазова»Российский нейрохирургический институт имени профессора А.Л. Поленова – филиал ФГБУ «Национальный медицинский исследовательский центр имени В.А. Алмазова»Intraoperative fluorescence diagnostics of high-grade gliomas is widely used in neurosurgical practice. This work analyzes the possibilities of fluorescence diagnostics for low-grade gliomas (LGG) using chlorin e6 photosensitizer. The study included patients with newly diagnosed LGG, for whom chlorin e6 was used for intraoperative fluorescence control at a dose of 1 mg/kg. During the operation, the fluorescence intensity of various areas of the putative tumor tissue was analyzed using the RSS Cam – Endo 1.4.313 software. Tissue samples with various degrees of fluorescence intensity were compared with the results of their histopathological analysis (WHO tumor diagnosis, Ki-67 index, P53, VEGF). Fluorescence was detected in more than half of the cases, but in most cases had a focal character and low fluorescence intensity. The fluorescence intensity directly correlated with the data of histopathological examination of tumor tissues (Ki-67 index (p=0.002), expression of P53 (p=0.0015) and VEGF (p=0.001)). The sensitivity of the method for LGG surgery was 72%, the specificity was 56,7%. Intraoperative fluorescence diagnostics with chlorin e6 can be used in LGG surgery, especially to visualize intratumoral areas with a higher degree of anaplasia.https://www.pdt-journal.com/jour/article/view/516глиомы низкой степени злокачественностихлорин е6интраоперационная флуоресцентная диагностиканейроонкология
spellingShingle A. Yu. Rynda
V. E. Olyushin
D. M. Rostovtsev
Y. M. Zabrodskaya
G. V. Papayan
Fluorescent diagnostics with chlorin e6 in surgery of low-grade glioma
Biomedical Photonics
глиомы низкой степени злокачественности
хлорин е6
интраоперационная флуоресцентная диагностика
нейроонкология
title Fluorescent diagnostics with chlorin e6 in surgery of low-grade glioma
title_full Fluorescent diagnostics with chlorin e6 in surgery of low-grade glioma
title_fullStr Fluorescent diagnostics with chlorin e6 in surgery of low-grade glioma
title_full_unstemmed Fluorescent diagnostics with chlorin e6 in surgery of low-grade glioma
title_short Fluorescent diagnostics with chlorin e6 in surgery of low-grade glioma
title_sort fluorescent diagnostics with chlorin e6 in surgery of low grade glioma
topic глиомы низкой степени злокачественности
хлорин е6
интраоперационная флуоресцентная диагностика
нейроонкология
url https://www.pdt-journal.com/jour/article/view/516
work_keys_str_mv AT ayurynda fluorescentdiagnosticswithchlorine6insurgeryoflowgradeglioma
AT veolyushin fluorescentdiagnosticswithchlorine6insurgeryoflowgradeglioma
AT dmrostovtsev fluorescentdiagnosticswithchlorine6insurgeryoflowgradeglioma
AT ymzabrodskaya fluorescentdiagnosticswithchlorine6insurgeryoflowgradeglioma
AT gvpapayan fluorescentdiagnosticswithchlorine6insurgeryoflowgradeglioma