Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope

Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotrac...

Full description

Bibliographic Details
Main Authors: Hamid Khosro Zamiri, Mehrdad Noroozi, Siavash Moradi, Mohammad Shabani, Ali Sharifi, Mohammad Ali Haghbin
Format: Article
Language:fas
Published: Fasa University of Medical Sciences 2013-09-01
Series:Journal of Fasa University of Medical Sciences
Subjects:
Online Access:http://journal.fums.ac.ir/browse.php?a_code=A-10-60-1&slc_lang=en&sid=1
_version_ 1819268487821918208
author Hamid Khosro Zamiri
Mehrdad Noroozi
Siavash Moradi
Mohammad Shabani
Ali Sharifi
Mohammad Ali Haghbin
author_facet Hamid Khosro Zamiri
Mehrdad Noroozi
Siavash Moradi
Mohammad Shabani
Ali Sharifi
Mohammad Ali Haghbin
author_sort Hamid Khosro Zamiri
collection DOAJ
description Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materials & Methods: One hundred and eighty patients with American Society of Anesthesiology (ASA) classification of I and II, aged 20-70 year, were enrolled in a randomized clinical trial (RCT). Anesthesia was induced by administration of Propofol 2 mg/kg, Fentanyl 1µg/kg and Cisatracurium 0.1mg/kg. the Hemodynamic information of the patients and intraocular pressures were documented and assessed in three stages (after induction of anesthesia and endotracheal intubation, and 5 minutes after endotracheal intubation using Maccoy, Macintosh and Video laryngoscope).Results: Hemodynamic parameters' of patients increased in these three groups compared with those of pre anesthesia measures, but this increase was not significant. Evaluation of intraocular pressure (IOP) in Video laryngoscope group showed that there is a significant drop in intraocular pressure (IOP) compared with other groups. There weren’t any significant differences of IOP after intubation in Maccoy compared to the Macintosh group. Nevertheless there was not any significant difference in IOP, before and five minutes after intubation in these groups.Conclusion: According to a low degree of augment of IOP in Video laryngoscope group and no changes in the Hemodynamic parameters, it seems that the use of Video laryngoscope in eye surgeries might be more suitable for endotracheal intubation.
first_indexed 2024-12-23T21:33:51Z
format Article
id doaj.art-9839c7eebad44580886723155c18dbcf
institution Directory Open Access Journal
issn 2228-5105
2228-7329
language fas
last_indexed 2024-12-23T21:33:51Z
publishDate 2013-09-01
publisher Fasa University of Medical Sciences
record_format Article
series Journal of Fasa University of Medical Sciences
spelling doaj.art-9839c7eebad44580886723155c18dbcf2022-12-21T17:30:23ZfasFasa University of Medical SciencesJournal of Fasa University of Medical Sciences2228-51052228-73292013-09-0132111116Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscopeHamid Khosro ZamiriMehrdad NorooziSiavash MoradiMohammad ShabaniAli SharifiMohammad Ali HaghbinBackground & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materials & Methods: One hundred and eighty patients with American Society of Anesthesiology (ASA) classification of I and II, aged 20-70 year, were enrolled in a randomized clinical trial (RCT). Anesthesia was induced by administration of Propofol 2 mg/kg, Fentanyl 1µg/kg and Cisatracurium 0.1mg/kg. the Hemodynamic information of the patients and intraocular pressures were documented and assessed in three stages (after induction of anesthesia and endotracheal intubation, and 5 minutes after endotracheal intubation using Maccoy, Macintosh and Video laryngoscope).Results: Hemodynamic parameters' of patients increased in these three groups compared with those of pre anesthesia measures, but this increase was not significant. Evaluation of intraocular pressure (IOP) in Video laryngoscope group showed that there is a significant drop in intraocular pressure (IOP) compared with other groups. There weren’t any significant differences of IOP after intubation in Maccoy compared to the Macintosh group. Nevertheless there was not any significant difference in IOP, before and five minutes after intubation in these groups.Conclusion: According to a low degree of augment of IOP in Video laryngoscope group and no changes in the Hemodynamic parameters, it seems that the use of Video laryngoscope in eye surgeries might be more suitable for endotracheal intubation.http://journal.fums.ac.ir/browse.php?a_code=A-10-60-1&slc_lang=en&sid=1Hemodynamic responsesIntraocular pressureLaryngoscopyVideo laryngoscope
spellingShingle Hamid Khosro Zamiri
Mehrdad Noroozi
Siavash Moradi
Mohammad Shabani
Ali Sharifi
Mohammad Ali Haghbin
Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
Journal of Fasa University of Medical Sciences
Hemodynamic responses
Intraocular pressure
Laryngoscopy
Video laryngoscope
title Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
title_full Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
title_fullStr Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
title_full_unstemmed Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
title_short Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
title_sort evaluation of intra ocular pressure and hemodynamic change following intubation with maccoy macintosh and video laryngoscope
topic Hemodynamic responses
Intraocular pressure
Laryngoscopy
Video laryngoscope
url http://journal.fums.ac.ir/browse.php?a_code=A-10-60-1&slc_lang=en&sid=1
work_keys_str_mv AT hamidkhosrozamiri evaluationofintraocularpressureandhemodynamicchangefollowingintubationwithmaccoymacintoshandvideolaryngoscope
AT mehrdadnoroozi evaluationofintraocularpressureandhemodynamicchangefollowingintubationwithmaccoymacintoshandvideolaryngoscope
AT siavashmoradi evaluationofintraocularpressureandhemodynamicchangefollowingintubationwithmaccoymacintoshandvideolaryngoscope
AT mohammadshabani evaluationofintraocularpressureandhemodynamicchangefollowingintubationwithmaccoymacintoshandvideolaryngoscope
AT alisharifi evaluationofintraocularpressureandhemodynamicchangefollowingintubationwithmaccoymacintoshandvideolaryngoscope
AT mohammadalihaghbin evaluationofintraocularpressureandhemodynamicchangefollowingintubationwithmaccoymacintoshandvideolaryngoscope