Evaluation of the Intensity of Lighting and Its Relationship with Students\' Visual Fatigue in Study Rooms of Zabol University of Medical Sciences in 2016
Introduction: Visual perception is one of the most important and critical human senses. This sense gets the most data and information from the environment. The studying hall is a place where students stay a long time, so its illumination should be so that makes them less fatigue. This study aimed to...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Shahid Sadoughi University of Medical Sciences
2017-11-01
|
Series: | بهداشت کار و ارتقای سلامت |
Subjects: | |
Online Access: | http://ohhp.ssu.ac.ir/browse.php?a_code=A-10-55-3&slc_lang=en&sid=1 |
_version_ | 1818350068955086848 |
---|---|
author | Somayeh BAGHERI Alireza DASTVAR Maryam GHALJAHI |
author_facet | Somayeh BAGHERI Alireza DASTVAR Maryam GHALJAHI |
author_sort | Somayeh BAGHERI |
collection | DOAJ |
description | Introduction: Visual perception is one of the most important and critical human senses. This sense gets the most data and information from the environment. The studying hall is a place where students stay a long time, so its illumination should be so that makes them less fatigue. This study aimed to evaluate the illumination and its relation on visual fatigue of Zabol Medical Science University students.
Methods: This cross-sectional study was carried out over 2 months in the study halls of the university. The illumination intensity was measured by Illuminating Engineering Society of North America. A questionnaire was completed and the data were analyzed using descriptive statistics.
Results: Public illumination in 99% and local illumination intensity in 100% of responses were evaluated less than the standard value. Although no significant difference was observed between age and visual fatigue, the local and public illumination intensity showed significant relation with visual fatigue and psychological condition.
Conclusion: Inappropriate lighting in studying halls, especially at nights when student spend more time for studying leads to visual fatigue. So, lighting design has to be reviewed based on the arrangement of lighting sources, optical proximity, and type of lighting sources |
first_indexed | 2024-12-13T18:15:58Z |
format | Article |
id | doaj.art-988a639401414abd98a91bc8b9e3c361 |
institution | Directory Open Access Journal |
issn | 2588-2643 2588-3062 |
language | fas |
last_indexed | 2024-12-13T18:15:58Z |
publishDate | 2017-11-01 |
publisher | Shahid Sadoughi University of Medical Sciences |
record_format | Article |
series | بهداشت کار و ارتقای سلامت |
spelling | doaj.art-988a639401414abd98a91bc8b9e3c3612022-12-21T23:35:50ZfasShahid Sadoughi University of Medical Sciencesبهداشت کار و ارتقای سلامت2588-26432588-30622017-11-0112154163Evaluation of the Intensity of Lighting and Its Relationship with Students\' Visual Fatigue in Study Rooms of Zabol University of Medical Sciences in 2016Somayeh BAGHERI0Alireza DASTVAR1Maryam GHALJAHI2 School of Health, Zabol University of Medical Science, Zabol, Iran Student of Occupational Health Engineering, School of Health, Zabol University of Medical Science, Zabol, Iran Department of Occupational Health Engineering, School of Health, Zabol University of Medical Science, Zabol, Iran Introduction: Visual perception is one of the most important and critical human senses. This sense gets the most data and information from the environment. The studying hall is a place where students stay a long time, so its illumination should be so that makes them less fatigue. This study aimed to evaluate the illumination and its relation on visual fatigue of Zabol Medical Science University students. Methods: This cross-sectional study was carried out over 2 months in the study halls of the university. The illumination intensity was measured by Illuminating Engineering Society of North America. A questionnaire was completed and the data were analyzed using descriptive statistics. Results: Public illumination in 99% and local illumination intensity in 100% of responses were evaluated less than the standard value. Although no significant difference was observed between age and visual fatigue, the local and public illumination intensity showed significant relation with visual fatigue and psychological condition. Conclusion: Inappropriate lighting in studying halls, especially at nights when student spend more time for studying leads to visual fatigue. So, lighting design has to be reviewed based on the arrangement of lighting sources, optical proximity, and type of lighting sourceshttp://ohhp.ssu.ac.ir/browse.php?a_code=A-10-55-3&slc_lang=en&sid=1Illumination Visual Fatigue Studying Hall |
spellingShingle | Somayeh BAGHERI Alireza DASTVAR Maryam GHALJAHI Evaluation of the Intensity of Lighting and Its Relationship with Students\' Visual Fatigue in Study Rooms of Zabol University of Medical Sciences in 2016 بهداشت کار و ارتقای سلامت Illumination Visual Fatigue Studying Hall |
title | Evaluation of the Intensity of Lighting and Its Relationship with Students\' Visual Fatigue in Study Rooms of Zabol University of Medical Sciences in 2016 |
title_full | Evaluation of the Intensity of Lighting and Its Relationship with Students\' Visual Fatigue in Study Rooms of Zabol University of Medical Sciences in 2016 |
title_fullStr | Evaluation of the Intensity of Lighting and Its Relationship with Students\' Visual Fatigue in Study Rooms of Zabol University of Medical Sciences in 2016 |
title_full_unstemmed | Evaluation of the Intensity of Lighting and Its Relationship with Students\' Visual Fatigue in Study Rooms of Zabol University of Medical Sciences in 2016 |
title_short | Evaluation of the Intensity of Lighting and Its Relationship with Students\' Visual Fatigue in Study Rooms of Zabol University of Medical Sciences in 2016 |
title_sort | evaluation of the intensity of lighting and its relationship with students visual fatigue in study rooms of zabol university of medical sciences in 2016 |
topic | Illumination Visual Fatigue Studying Hall |
url | http://ohhp.ssu.ac.ir/browse.php?a_code=A-10-55-3&slc_lang=en&sid=1 |
work_keys_str_mv | AT somayehbagheri evaluationoftheintensityoflightinganditsrelationshipwithstudentsvisualfatigueinstudyroomsofzaboluniversityofmedicalsciencesin2016 AT alirezadastvar evaluationoftheintensityoflightinganditsrelationshipwithstudentsvisualfatigueinstudyroomsofzaboluniversityofmedicalsciencesin2016 AT maryamghaljahi evaluationoftheintensityoflightinganditsrelationshipwithstudentsvisualfatigueinstudyroomsofzaboluniversityofmedicalsciencesin2016 |