Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage

Inter-turn short circuit in the excitation windings of synchronous condensers is a common fault that directly impacts their normal operation. However, current fault analysis and diagnosis of synchronous condensers primarily rely on voltage-balanced conditions, while research on short-circuit faults...

Full description

Bibliographic Details
Main Authors: Junqing Li, Chengzhi Zhang, Yuling He, Xiaodong Hu, Jiya Geng, Yapeng Ma
Format: Article
Language:English
Published: MDPI AG 2023-07-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/16/15/5695
_version_ 1797586820542758912
author Junqing Li
Chengzhi Zhang
Yuling He
Xiaodong Hu
Jiya Geng
Yapeng Ma
author_facet Junqing Li
Chengzhi Zhang
Yuling He
Xiaodong Hu
Jiya Geng
Yapeng Ma
author_sort Junqing Li
collection DOAJ
description Inter-turn short circuit in the excitation windings of synchronous condensers is a common fault that directly impacts their normal operation. However, current fault analysis and diagnosis of synchronous condensers primarily rely on voltage-balanced conditions, while research on short-circuit faults under unbalanced voltage conditions is limited. Therefore, this paper aims to analyze the fault characteristics of inter-turn short circuits in the excitation windings of synchronous condensers under unbalanced grid voltage. Mathematical models were developed to represent the air gap flux density and stator parallel currents for four operating conditions: normal operation and inter-turn short circuit fault under balanced voltage, as well as a process without fault and with inter-turn short circuit fault under unbalanced voltage. By comparing the harmonic content and amplitudes, various aspects of the fault mechanism of synchronous condensers were revealed, and the operating characteristics under different conditions were analyzed. Considering the four aforementioned operating conditions, finite element simulation models were created for the TTS-300-2 synchronous condenser in a specific substation as a case study. The results demonstrate that the inter-turn short circuit fault in the excitation windings under unbalanced voltage leads to an increase in even harmonic currents in the stator parallel currents, particularly the second and fourth harmonics. This validates the accuracy of the theoretical analysis findings.
first_indexed 2024-03-11T00:28:34Z
format Article
id doaj.art-989807286a864192851fd655558050d2
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-11T00:28:34Z
publishDate 2023-07-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-989807286a864192851fd655558050d22023-11-18T22:51:38ZengMDPI AGEnergies1996-10732023-07-011615569510.3390/en16155695Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced VoltageJunqing Li0Chengzhi Zhang1Yuling He2Xiaodong Hu3Jiya Geng4Yapeng Ma5School of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, ChinaSchool of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, ChinaDepartment of Mechanical Engineering, North China Electric Power University, Baoding 071003, ChinaSchool of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, ChinaSchool of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, ChinaSchool of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, ChinaInter-turn short circuit in the excitation windings of synchronous condensers is a common fault that directly impacts their normal operation. However, current fault analysis and diagnosis of synchronous condensers primarily rely on voltage-balanced conditions, while research on short-circuit faults under unbalanced voltage conditions is limited. Therefore, this paper aims to analyze the fault characteristics of inter-turn short circuits in the excitation windings of synchronous condensers under unbalanced grid voltage. Mathematical models were developed to represent the air gap flux density and stator parallel currents for four operating conditions: normal operation and inter-turn short circuit fault under balanced voltage, as well as a process without fault and with inter-turn short circuit fault under unbalanced voltage. By comparing the harmonic content and amplitudes, various aspects of the fault mechanism of synchronous condensers were revealed, and the operating characteristics under different conditions were analyzed. Considering the four aforementioned operating conditions, finite element simulation models were created for the TTS-300-2 synchronous condenser in a specific substation as a case study. The results demonstrate that the inter-turn short circuit fault in the excitation windings under unbalanced voltage leads to an increase in even harmonic currents in the stator parallel currents, particularly the second and fourth harmonics. This validates the accuracy of the theoretical analysis findings.https://www.mdpi.com/1996-1073/16/15/5695synchronous condenserunbalanced voltageinter-turn short circuit in excitation windingsfinite elementfault analysisstator parallel currents
spellingShingle Junqing Li
Chengzhi Zhang
Yuling He
Xiaodong Hu
Jiya Geng
Yapeng Ma
Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage
Energies
synchronous condenser
unbalanced voltage
inter-turn short circuit in excitation windings
finite element
fault analysis
stator parallel currents
title Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage
title_full Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage
title_fullStr Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage
title_full_unstemmed Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage
title_short Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage
title_sort impact of inter turn short circuit in excitation windings on magnetic field and stator current of synchronous condenser under unbalanced voltage
topic synchronous condenser
unbalanced voltage
inter-turn short circuit in excitation windings
finite element
fault analysis
stator parallel currents
url https://www.mdpi.com/1996-1073/16/15/5695
work_keys_str_mv AT junqingli impactofinterturnshortcircuitinexcitationwindingsonmagneticfieldandstatorcurrentofsynchronouscondenserunderunbalancedvoltage
AT chengzhizhang impactofinterturnshortcircuitinexcitationwindingsonmagneticfieldandstatorcurrentofsynchronouscondenserunderunbalancedvoltage
AT yulinghe impactofinterturnshortcircuitinexcitationwindingsonmagneticfieldandstatorcurrentofsynchronouscondenserunderunbalancedvoltage
AT xiaodonghu impactofinterturnshortcircuitinexcitationwindingsonmagneticfieldandstatorcurrentofsynchronouscondenserunderunbalancedvoltage
AT jiyageng impactofinterturnshortcircuitinexcitationwindingsonmagneticfieldandstatorcurrentofsynchronouscondenserunderunbalancedvoltage
AT yapengma impactofinterturnshortcircuitinexcitationwindingsonmagneticfieldandstatorcurrentofsynchronouscondenserunderunbalancedvoltage