Design of a Grooved Cross-Section Silicon Needle for Assisting Deep Implantation of Flexible Neural Probe
Aimed at the buckling problem of deep implantation of flexible neural probe, a grooved cross-section silicon needle is designed as an auxiliary implant tool to provide temporary stiffness for probe implantation. In order to quantitatively evaluate the comprehensive performance of auxiliary tools, co...
Main Author: | |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Office of Journal of Shanghai Jiao Tong University
2022-05-01
|
Series: | Shanghai Jiaotong Daxue xuebao |
Subjects: | |
Online Access: | http://xuebao.sjtu.edu.cn/article/2022/1006-2467/1006-2467-56-5-648.shtml |
_version_ | 1818547184562339840 |
---|---|
author | HE Yuxin, ZHANG Wenguang, XU Liyue, ZHOU Xuhui |
author_facet | HE Yuxin, ZHANG Wenguang, XU Liyue, ZHOU Xuhui |
author_sort | HE Yuxin, ZHANG Wenguang, XU Liyue, ZHOU Xuhui |
collection | DOAJ |
description | Aimed at the buckling problem of deep implantation of flexible neural probe, a grooved cross-section silicon needle is designed as an auxiliary implant tool to provide temporary stiffness for probe implantation. In order to quantitatively evaluate the comprehensive performance of auxiliary tools, combining critical buckling force and cross-section area, and considering mechanical and biological properties, the performance evaluation index of auxiliary tools is proposed. Based on this evaluation index, the optimal groove depth ratio and groove width ratio of the grooved cross-section silicon needle are studied. The best groove depth ratio is the maximum value within the process requirements while the best groove width ratio increases with the thickness of the silicon needle. Moreover, the performance evaluation index is used to quantitatively prove that the grooved cross-section silicon needle has obvious performance advantages over the traditional circular and rectangular cross-section silicon needles. The simulation design of the grooved cross-section silicon needle is conducive to screening the best parameter combination of the cross-section, reducing the number of processing and the cost of experiments. |
first_indexed | 2024-12-12T08:03:19Z |
format | Article |
id | doaj.art-98a80208e2f04e18abcc4ff104b23203 |
institution | Directory Open Access Journal |
issn | 1006-2467 |
language | zho |
last_indexed | 2024-12-12T08:03:19Z |
publishDate | 2022-05-01 |
publisher | Editorial Office of Journal of Shanghai Jiao Tong University |
record_format | Article |
series | Shanghai Jiaotong Daxue xuebao |
spelling | doaj.art-98a80208e2f04e18abcc4ff104b232032022-12-22T00:32:03ZzhoEditorial Office of Journal of Shanghai Jiao Tong UniversityShanghai Jiaotong Daxue xuebao1006-24672022-05-0156564865510.16183/j.cnki.jsjtu.2020.341Design of a Grooved Cross-Section Silicon Needle for Assisting Deep Implantation of Flexible Neural ProbeHE Yuxin, ZHANG Wenguang, XU Liyue, ZHOU Xuhui0State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, ChinaAimed at the buckling problem of deep implantation of flexible neural probe, a grooved cross-section silicon needle is designed as an auxiliary implant tool to provide temporary stiffness for probe implantation. In order to quantitatively evaluate the comprehensive performance of auxiliary tools, combining critical buckling force and cross-section area, and considering mechanical and biological properties, the performance evaluation index of auxiliary tools is proposed. Based on this evaluation index, the optimal groove depth ratio and groove width ratio of the grooved cross-section silicon needle are studied. The best groove depth ratio is the maximum value within the process requirements while the best groove width ratio increases with the thickness of the silicon needle. Moreover, the performance evaluation index is used to quantitatively prove that the grooved cross-section silicon needle has obvious performance advantages over the traditional circular and rectangular cross-section silicon needles. The simulation design of the grooved cross-section silicon needle is conducive to screening the best parameter combination of the cross-section, reducing the number of processing and the cost of experiments.http://xuebao.sjtu.edu.cn/article/2022/1006-2467/1006-2467-56-5-648.shtmlflexible neural probeimplantation strategygrooved cross-sectionsilicon needle |
spellingShingle | HE Yuxin, ZHANG Wenguang, XU Liyue, ZHOU Xuhui Design of a Grooved Cross-Section Silicon Needle for Assisting Deep Implantation of Flexible Neural Probe Shanghai Jiaotong Daxue xuebao flexible neural probe implantation strategy grooved cross-section silicon needle |
title | Design of a Grooved Cross-Section Silicon Needle for Assisting Deep Implantation of Flexible Neural Probe |
title_full | Design of a Grooved Cross-Section Silicon Needle for Assisting Deep Implantation of Flexible Neural Probe |
title_fullStr | Design of a Grooved Cross-Section Silicon Needle for Assisting Deep Implantation of Flexible Neural Probe |
title_full_unstemmed | Design of a Grooved Cross-Section Silicon Needle for Assisting Deep Implantation of Flexible Neural Probe |
title_short | Design of a Grooved Cross-Section Silicon Needle for Assisting Deep Implantation of Flexible Neural Probe |
title_sort | design of a grooved cross section silicon needle for assisting deep implantation of flexible neural probe |
topic | flexible neural probe implantation strategy grooved cross-section silicon needle |
url | http://xuebao.sjtu.edu.cn/article/2022/1006-2467/1006-2467-56-5-648.shtml |
work_keys_str_mv | AT heyuxinzhangwenguangxuliyuezhouxuhui designofagroovedcrosssectionsiliconneedleforassistingdeepimplantationofflexibleneuralprobe |