The Study of the Status of Electromagnetic Waves Resulting from BTS (Base Transceiver Station), 900 Megahertz Frequency in Tehran

Background and Objectives: with the developments of technology, contact with various frequencies of electromagnetic fields ( EMF ) has significantly increased, while the abundant benefits of using microwaves in routine life cannot be neglected. During recent years there have been reports of adverse...

Full description

Bibliographic Details
Main Authors: R Hematjo, Z Yousefi, K Azam, S Zare, M.R Monazam, P Nasiri
Format: Article
Language:fas
Published: Tehran University of Medical Sciences 2011-10-01
Series:سلامت و محیط
Subjects:
Online Access:http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/20261.pdf&manuscript_id=20261
_version_ 1818682417075978240
author R Hematjo
Z Yousefi
K Azam
S Zare
M.R Monazam
P Nasiri
author_facet R Hematjo
Z Yousefi
K Azam
S Zare
M.R Monazam
P Nasiri
author_sort R Hematjo
collection DOAJ
description Background and Objectives: with the developments of technology, contact with various frequencies of electromagnetic fields ( EMF ) has significantly increased, while the abundant benefits of using microwaves in routine life cannot be neglected. During recent years there have been reports of adverse effects caused by contact with electric and magnetic fields of these waves that spread from BTS antennas. The purpose of this study is the measurement of microwaves spreading around BTS antennas in Tehran.Materials and Methods:  according to the location of BTS antennas in Tehran , power density of electromagnetic waves around 63 antennas in near and distant fields in different distances was measured. The measurements were performed using the standard method of IEEE Std C95.1 by Hi-4333 device .in order to analysis data we used spss 16 and descriptive and deductive statistical tests.Results: results of this study show that in the near field, with increase of distance from the foot of antenna , the average power density of electromagnetic waves increase in a way that in the distance of 10 meters from the antenna foot , the increase of average power density is hardly conceivable and from 10 to 15 meters distance is perfectly noticeable. But in the distant field, with increase of distance from 20 meters, the average power density of the electromagnetic waves decreases; and from 100 meter and further, the gradient of the diagram will get almost linear and the rate of power density reaches the base limit in a way that with the increase of distance there would be no significant decrease.Conclusion: All the measures of power density of electromagnetic waves caused by BTSs are about 0.06% of recommended measures of environmental standards and 0.0000013% of occupational standards. The results of this study are close to the results of other studies.
first_indexed 2024-12-17T10:18:30Z
format Article
id doaj.art-98b6c33d93d849b6bce1a4b60af60516
institution Directory Open Access Journal
issn 2008-2029
2008-3718
language fas
last_indexed 2024-12-17T10:18:30Z
publishDate 2011-10-01
publisher Tehran University of Medical Sciences
record_format Article
series سلامت و محیط
spelling doaj.art-98b6c33d93d849b6bce1a4b60af605162022-12-21T21:52:51ZfasTehran University of Medical Sciencesسلامت و محیط2008-20292008-37182011-10-0143331340The Study of the Status of Electromagnetic Waves Resulting from BTS (Base Transceiver Station), 900 Megahertz Frequency in TehranR HematjoZ YousefiK AzamS ZareM.R MonazamP NasiriBackground and Objectives: with the developments of technology, contact with various frequencies of electromagnetic fields ( EMF ) has significantly increased, while the abundant benefits of using microwaves in routine life cannot be neglected. During recent years there have been reports of adverse effects caused by contact with electric and magnetic fields of these waves that spread from BTS antennas. The purpose of this study is the measurement of microwaves spreading around BTS antennas in Tehran.Materials and Methods:  according to the location of BTS antennas in Tehran , power density of electromagnetic waves around 63 antennas in near and distant fields in different distances was measured. The measurements were performed using the standard method of IEEE Std C95.1 by Hi-4333 device .in order to analysis data we used spss 16 and descriptive and deductive statistical tests.Results: results of this study show that in the near field, with increase of distance from the foot of antenna , the average power density of electromagnetic waves increase in a way that in the distance of 10 meters from the antenna foot , the increase of average power density is hardly conceivable and from 10 to 15 meters distance is perfectly noticeable. But in the distant field, with increase of distance from 20 meters, the average power density of the electromagnetic waves decreases; and from 100 meter and further, the gradient of the diagram will get almost linear and the rate of power density reaches the base limit in a way that with the increase of distance there would be no significant decrease.Conclusion: All the measures of power density of electromagnetic waves caused by BTSs are about 0.06% of recommended measures of environmental standards and 0.0000013% of occupational standards. The results of this study are close to the results of other studies.http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/20261.pdf&manuscript_id=20261BTS AntennaPower DensityElectromagnetic WavesHealth EffectsMicrowave
spellingShingle R Hematjo
Z Yousefi
K Azam
S Zare
M.R Monazam
P Nasiri
The Study of the Status of Electromagnetic Waves Resulting from BTS (Base Transceiver Station), 900 Megahertz Frequency in Tehran
سلامت و محیط
BTS Antenna
Power Density
Electromagnetic Waves
Health Effects
Microwave
title The Study of the Status of Electromagnetic Waves Resulting from BTS (Base Transceiver Station), 900 Megahertz Frequency in Tehran
title_full The Study of the Status of Electromagnetic Waves Resulting from BTS (Base Transceiver Station), 900 Megahertz Frequency in Tehran
title_fullStr The Study of the Status of Electromagnetic Waves Resulting from BTS (Base Transceiver Station), 900 Megahertz Frequency in Tehran
title_full_unstemmed The Study of the Status of Electromagnetic Waves Resulting from BTS (Base Transceiver Station), 900 Megahertz Frequency in Tehran
title_short The Study of the Status of Electromagnetic Waves Resulting from BTS (Base Transceiver Station), 900 Megahertz Frequency in Tehran
title_sort study of the status of electromagnetic waves resulting from bts base transceiver station 900 megahertz frequency in tehran
topic BTS Antenna
Power Density
Electromagnetic Waves
Health Effects
Microwave
url http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/20261.pdf&manuscript_id=20261
work_keys_str_mv AT rhematjo thestudyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT zyousefi thestudyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT kazam thestudyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT szare thestudyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT mrmonazam thestudyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT pnasiri thestudyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT rhematjo studyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT zyousefi studyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT kazam studyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT szare studyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT mrmonazam studyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran
AT pnasiri studyofthestatusofelectromagneticwavesresultingfrombtsbasetransceiverstation900megahertzfrequencyintehran