Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study

Abstract Background In the clinic, most computer-aided design and manufacturing orthodontic mini-implant guides are suitable for the position between the tooth roots, and few templates are designed and used for the infrazygomatic crest zone. In this study, we took into account the structure of the i...

Full description

Bibliographic Details
Main Authors: Li Su, Hui Song, Xiaofeng Huang
Format: Article
Language:English
Published: BMC 2022-06-01
Series:BMC Oral Health
Subjects:
Online Access:https://doi.org/10.1186/s12903-022-02285-0
_version_ 1818550416971923456
author Li Su
Hui Song
Xiaofeng Huang
author_facet Li Su
Hui Song
Xiaofeng Huang
author_sort Li Su
collection DOAJ
description Abstract Background In the clinic, most computer-aided design and manufacturing orthodontic mini-implant guides are suitable for the position between the tooth roots, and few templates are designed and used for the infrazygomatic crest zone. In this study, we took into account the structure of the infrazygomatic crest and 3D printing technology, developed two kinds of templates, and evaluated their clinical effects. Methods Seventeen patients who accepted 30 mini-implant insertions in the infrazygomatic crest were selected. According to different implantation methods, three groups were divided. In Groups A and B, the mini-implants were positioned with an A-type or B-type template designed by EXOCAD software. In Group C, the mini-implants were inserted by an experienced orthodontist without any guides. We simulate the bucco-palatal, mesio-distal, and vertical head positions in the Segma implant guide software and measure the deviation from the virtual design position of the mini-implant. The linear deviation of the mini-implant tip and cap and the angular deviation of the long axis of the mini-implant in the bucco-palatal direction, mesio-distal direction, and vertical direction were also measured. The results were statistically analysed by SPSS software. Results The deviations of Group A and Group C’s miniscrew cap in the bucco-palatal direction, Group A and Group B, Group A and Group C’s miniscrew tip in the mesio-distal direction, and Group B and Group C’s miniscrew tip and cap in the vertical direction were statistically significant (P < 0.05). There was a significant difference in the deviations of Group A and Group C’s miniscrew tip and cap in the vertical direction (P < 0.01). Conclusions In the vertical direction, the accuracy of implantation with the template is higher than that of the traditional method without the template to avoid piercing the maxillary sinus mucosa in the infrazygomatic crest zone.
first_indexed 2024-12-12T08:46:11Z
format Article
id doaj.art-98be76526643426b85988fd067e4eaf4
institution Directory Open Access Journal
issn 1472-6831
language English
last_indexed 2024-12-12T08:46:11Z
publishDate 2022-06-01
publisher BMC
record_format Article
series BMC Oral Health
spelling doaj.art-98be76526643426b85988fd067e4eaf42022-12-22T00:30:32ZengBMCBMC Oral Health1472-68312022-06-012211710.1186/s12903-022-02285-0Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort studyLi Su0Hui Song1Xiaofeng Huang2Department of Stomatology, Beijing Xuanwu TCM HospitalDepartment of Stomatology, Beijing Xuanwu TCM HospitalDepartment of Stomatology, Beijing Friendship Hospital, Capital Medical UniversityAbstract Background In the clinic, most computer-aided design and manufacturing orthodontic mini-implant guides are suitable for the position between the tooth roots, and few templates are designed and used for the infrazygomatic crest zone. In this study, we took into account the structure of the infrazygomatic crest and 3D printing technology, developed two kinds of templates, and evaluated their clinical effects. Methods Seventeen patients who accepted 30 mini-implant insertions in the infrazygomatic crest were selected. According to different implantation methods, three groups were divided. In Groups A and B, the mini-implants were positioned with an A-type or B-type template designed by EXOCAD software. In Group C, the mini-implants were inserted by an experienced orthodontist without any guides. We simulate the bucco-palatal, mesio-distal, and vertical head positions in the Segma implant guide software and measure the deviation from the virtual design position of the mini-implant. The linear deviation of the mini-implant tip and cap and the angular deviation of the long axis of the mini-implant in the bucco-palatal direction, mesio-distal direction, and vertical direction were also measured. The results were statistically analysed by SPSS software. Results The deviations of Group A and Group C’s miniscrew cap in the bucco-palatal direction, Group A and Group B, Group A and Group C’s miniscrew tip in the mesio-distal direction, and Group B and Group C’s miniscrew tip and cap in the vertical direction were statistically significant (P < 0.05). There was a significant difference in the deviations of Group A and Group C’s miniscrew tip and cap in the vertical direction (P < 0.01). Conclusions In the vertical direction, the accuracy of implantation with the template is higher than that of the traditional method without the template to avoid piercing the maxillary sinus mucosa in the infrazygomatic crest zone.https://doi.org/10.1186/s12903-022-02285-0Infrazygomatic crestMini-implantTemplate
spellingShingle Li Su
Hui Song
Xiaofeng Huang
Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study
BMC Oral Health
Infrazygomatic crest
Mini-implant
Template
title Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study
title_full Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study
title_fullStr Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study
title_full_unstemmed Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study
title_short Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study
title_sort accuracy of two orthodontic mini implant templates in the infrazygomatic crest zone a prospective cohort study
topic Infrazygomatic crest
Mini-implant
Template
url https://doi.org/10.1186/s12903-022-02285-0
work_keys_str_mv AT lisu accuracyoftwoorthodonticminiimplanttemplatesintheinfrazygomaticcrestzoneaprospectivecohortstudy
AT huisong accuracyoftwoorthodonticminiimplanttemplatesintheinfrazygomaticcrestzoneaprospectivecohortstudy
AT xiaofenghuang accuracyoftwoorthodonticminiimplanttemplatesintheinfrazygomaticcrestzoneaprospectivecohortstudy