Deflection of tandem archwire in a specific self-ligating metal bracket system: an in vitro study
Abstract The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 – two .014” + .014” round archwires; G2 – two .0...