Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)
Background Fractional exhaled nitric oxide (FeNO) is a non-invasive marker for eosinophilic airway inflammation and a good predictor of response to corticosteroids. There is a need for a reliable and accurate measurement method, as FeNO measurements have been widely used in clinical practice. Our st...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Korean Academy of Tuberculosis and Respiratory Diseases
2021-07-01
|
Series: | Tuberculosis and Respiratory Diseases |
Subjects: | |
Online Access: | http://e-trd.org/upload/pdf/trd-2020-0137.pdf |
_version_ | 1819005711692070912 |
---|---|
author | Sung-Yoon Kang Sang Min Lee Sang Pyo Lee |
author_facet | Sung-Yoon Kang Sang Min Lee Sang Pyo Lee |
author_sort | Sung-Yoon Kang |
collection | DOAJ |
description | Background Fractional exhaled nitric oxide (FeNO) is a non-invasive marker for eosinophilic airway inflammation and a good predictor of response to corticosteroids. There is a need for a reliable and accurate measurement method, as FeNO measurements have been widely used in clinical practice. Our study aimed to compare two FeNO analyzers and derive a conversion equation for FeNO measurements in adults. Methods We included 99 participants who had chief complaints of chronic cough and difficulty in breathing. The participants underwent concurrent FeNO measurement using NIOX VERO (Circassia AB) and NObreath (Bedfont). We compared the values of the two devices and analyzed their correlation and agreement. We then formulated an equation to convert FeNO values measured by NObreath into those obtained by NIOX VERO. Results The mean age of the participants was 51.2±17.1 years, with a female predominance (58.6%). Approximately 60% of the participants had asthma. The FeNO level measured by NIOX VERO (median, 27; interquartile range [IQR], 15–45) was significantly lower than that measured by NObreath (median, 38; IQR, 22–58; p<0.001). There was a strong positive correlation between the two devices (r=0.779, p<0.001). Additionally, Bland-Altman plots and intraclass correlation coefficient demonstrated a good agreement. Using linear regression, we derived the following conversion equation: natural log (Ln) (NObreath)=0.728×Ln (NIOX VERO)+1.244. Conclusion The FeNO values of NIOX VERO and NObreath were in good agreement and had positive correlations. Our proposed conversion equation could help assess the accuracy of the two analyzers. |
first_indexed | 2024-12-20T23:57:08Z |
format | Article |
id | doaj.art-999966ff31504ec7b2c321e351732a3b |
institution | Directory Open Access Journal |
issn | 1738-3536 2005-6184 |
language | English |
last_indexed | 2024-12-20T23:57:08Z |
publishDate | 2021-07-01 |
publisher | The Korean Academy of Tuberculosis and Respiratory Diseases |
record_format | Article |
series | Tuberculosis and Respiratory Diseases |
spelling | doaj.art-999966ff31504ec7b2c321e351732a3b2022-12-21T19:22:43ZengThe Korean Academy of Tuberculosis and Respiratory DiseasesTuberculosis and Respiratory Diseases1738-35362005-61842021-07-0184318218710.4046/trd.2020.01374568Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)Sung-Yoon KangSang Min LeeSang Pyo LeeBackground Fractional exhaled nitric oxide (FeNO) is a non-invasive marker for eosinophilic airway inflammation and a good predictor of response to corticosteroids. There is a need for a reliable and accurate measurement method, as FeNO measurements have been widely used in clinical practice. Our study aimed to compare two FeNO analyzers and derive a conversion equation for FeNO measurements in adults. Methods We included 99 participants who had chief complaints of chronic cough and difficulty in breathing. The participants underwent concurrent FeNO measurement using NIOX VERO (Circassia AB) and NObreath (Bedfont). We compared the values of the two devices and analyzed their correlation and agreement. We then formulated an equation to convert FeNO values measured by NObreath into those obtained by NIOX VERO. Results The mean age of the participants was 51.2±17.1 years, with a female predominance (58.6%). Approximately 60% of the participants had asthma. The FeNO level measured by NIOX VERO (median, 27; interquartile range [IQR], 15–45) was significantly lower than that measured by NObreath (median, 38; IQR, 22–58; p<0.001). There was a strong positive correlation between the two devices (r=0.779, p<0.001). Additionally, Bland-Altman plots and intraclass correlation coefficient demonstrated a good agreement. Using linear regression, we derived the following conversion equation: natural log (Ln) (NObreath)=0.728×Ln (NIOX VERO)+1.244. Conclusion The FeNO values of NIOX VERO and NObreath were in good agreement and had positive correlations. Our proposed conversion equation could help assess the accuracy of the two analyzers.http://e-trd.org/upload/pdf/trd-2020-0137.pdfexhalationnitric oxidebiomarkersrespiratory disease |
spellingShingle | Sung-Yoon Kang Sang Min Lee Sang Pyo Lee Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath) Tuberculosis and Respiratory Diseases exhalation nitric oxide biomarkers respiratory disease |
title | Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath) |
title_full | Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath) |
title_fullStr | Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath) |
title_full_unstemmed | Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath) |
title_short | Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath) |
title_sort | measurement of fractional exhaled nitric oxide in adults comparison of two different analyzers niox vero and nobreath |
topic | exhalation nitric oxide biomarkers respiratory disease |
url | http://e-trd.org/upload/pdf/trd-2020-0137.pdf |
work_keys_str_mv | AT sungyoonkang measurementoffractionalexhalednitricoxideinadultscomparisonoftwodifferentanalyzersnioxveroandnobreath AT sangminlee measurementoffractionalexhalednitricoxideinadultscomparisonoftwodifferentanalyzersnioxveroandnobreath AT sangpyolee measurementoffractionalexhalednitricoxideinadultscomparisonoftwodifferentanalyzersnioxveroandnobreath |