Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)

Background Fractional exhaled nitric oxide (FeNO) is a non-invasive marker for eosinophilic airway inflammation and a good predictor of response to corticosteroids. There is a need for a reliable and accurate measurement method, as FeNO measurements have been widely used in clinical practice. Our st...

Full description

Bibliographic Details
Main Authors: Sung-Yoon Kang, Sang Min Lee, Sang Pyo Lee
Format: Article
Language:English
Published: The Korean Academy of Tuberculosis and Respiratory Diseases 2021-07-01
Series:Tuberculosis and Respiratory Diseases
Subjects:
Online Access:http://e-trd.org/upload/pdf/trd-2020-0137.pdf
_version_ 1819005711692070912
author Sung-Yoon Kang
Sang Min Lee
Sang Pyo Lee
author_facet Sung-Yoon Kang
Sang Min Lee
Sang Pyo Lee
author_sort Sung-Yoon Kang
collection DOAJ
description Background Fractional exhaled nitric oxide (FeNO) is a non-invasive marker for eosinophilic airway inflammation and a good predictor of response to corticosteroids. There is a need for a reliable and accurate measurement method, as FeNO measurements have been widely used in clinical practice. Our study aimed to compare two FeNO analyzers and derive a conversion equation for FeNO measurements in adults. Methods We included 99 participants who had chief complaints of chronic cough and difficulty in breathing. The participants underwent concurrent FeNO measurement using NIOX VERO (Circassia AB) and NObreath (Bedfont). We compared the values of the two devices and analyzed their correlation and agreement. We then formulated an equation to convert FeNO values measured by NObreath into those obtained by NIOX VERO. Results The mean age of the participants was 51.2±17.1 years, with a female predominance (58.6%). Approximately 60% of the participants had asthma. The FeNO level measured by NIOX VERO (median, 27; interquartile range [IQR], 15–45) was significantly lower than that measured by NObreath (median, 38; IQR, 22–58; p<0.001). There was a strong positive correlation between the two devices (r=0.779, p<0.001). Additionally, Bland-Altman plots and intraclass correlation coefficient demonstrated a good agreement. Using linear regression, we derived the following conversion equation: natural log (Ln) (NObreath)=0.728×Ln (NIOX VERO)+1.244. Conclusion The FeNO values of NIOX VERO and NObreath were in good agreement and had positive correlations. Our proposed conversion equation could help assess the accuracy of the two analyzers.
first_indexed 2024-12-20T23:57:08Z
format Article
id doaj.art-999966ff31504ec7b2c321e351732a3b
institution Directory Open Access Journal
issn 1738-3536
2005-6184
language English
last_indexed 2024-12-20T23:57:08Z
publishDate 2021-07-01
publisher The Korean Academy of Tuberculosis and Respiratory Diseases
record_format Article
series Tuberculosis and Respiratory Diseases
spelling doaj.art-999966ff31504ec7b2c321e351732a3b2022-12-21T19:22:43ZengThe Korean Academy of Tuberculosis and Respiratory DiseasesTuberculosis and Respiratory Diseases1738-35362005-61842021-07-0184318218710.4046/trd.2020.01374568Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)Sung-Yoon KangSang Min LeeSang Pyo LeeBackground Fractional exhaled nitric oxide (FeNO) is a non-invasive marker for eosinophilic airway inflammation and a good predictor of response to corticosteroids. There is a need for a reliable and accurate measurement method, as FeNO measurements have been widely used in clinical practice. Our study aimed to compare two FeNO analyzers and derive a conversion equation for FeNO measurements in adults. Methods We included 99 participants who had chief complaints of chronic cough and difficulty in breathing. The participants underwent concurrent FeNO measurement using NIOX VERO (Circassia AB) and NObreath (Bedfont). We compared the values of the two devices and analyzed their correlation and agreement. We then formulated an equation to convert FeNO values measured by NObreath into those obtained by NIOX VERO. Results The mean age of the participants was 51.2±17.1 years, with a female predominance (58.6%). Approximately 60% of the participants had asthma. The FeNO level measured by NIOX VERO (median, 27; interquartile range [IQR], 15–45) was significantly lower than that measured by NObreath (median, 38; IQR, 22–58; p<0.001). There was a strong positive correlation between the two devices (r=0.779, p<0.001). Additionally, Bland-Altman plots and intraclass correlation coefficient demonstrated a good agreement. Using linear regression, we derived the following conversion equation: natural log (Ln) (NObreath)=0.728×Ln (NIOX VERO)+1.244. Conclusion The FeNO values of NIOX VERO and NObreath were in good agreement and had positive correlations. Our proposed conversion equation could help assess the accuracy of the two analyzers.http://e-trd.org/upload/pdf/trd-2020-0137.pdfexhalationnitric oxidebiomarkersrespiratory disease
spellingShingle Sung-Yoon Kang
Sang Min Lee
Sang Pyo Lee
Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)
Tuberculosis and Respiratory Diseases
exhalation
nitric oxide
biomarkers
respiratory disease
title Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)
title_full Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)
title_fullStr Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)
title_full_unstemmed Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)
title_short Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)
title_sort measurement of fractional exhaled nitric oxide in adults comparison of two different analyzers niox vero and nobreath
topic exhalation
nitric oxide
biomarkers
respiratory disease
url http://e-trd.org/upload/pdf/trd-2020-0137.pdf
work_keys_str_mv AT sungyoonkang measurementoffractionalexhalednitricoxideinadultscomparisonoftwodifferentanalyzersnioxveroandnobreath
AT sangminlee measurementoffractionalexhalednitricoxideinadultscomparisonoftwodifferentanalyzersnioxveroandnobreath
AT sangpyolee measurementoffractionalexhalednitricoxideinadultscomparisonoftwodifferentanalyzersnioxveroandnobreath