Vertical Electric Sounding of Leachate Contaminant Plumes at a Dumpsite in Obigbo, Rivers State, Nigeria

The quality of underground water at a dumpsite in Obigbo, Rivers State, Nigeria, was investigated by collecting 7 vertical electrical soundings (VES) using Wenner electrode configuration with current electrode spacing (AB/2) ranging from 1.0 m to 300 m. Field data were acquired using the SAS 300C r...

Full description

Bibliographic Details
Main Authors: W. Tamuno, S. Inichinbia
Format: Article
Language:English
Published: Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP) 2020-01-01
Series:Journal of Applied Sciences and Environmental Management
Subjects:
Online Access:https://www.ajol.info/index.php/jasem/article/view/192549
_version_ 1797197542833782784
author W. Tamuno
S. Inichinbia
author_facet W. Tamuno
S. Inichinbia
author_sort W. Tamuno
collection DOAJ
description The quality of underground water at a dumpsite in Obigbo, Rivers State, Nigeria, was investigated by collecting 7 vertical electrical soundings (VES) using Wenner electrode configuration with current electrode spacing (AB/2) ranging from 1.0 m to 300 m. Field data were acquired using the SAS 300C resistivity meter and accessories, coordinates and elevation were measured using the Global Positioning System (GPS) at each sounding station. The VES data showed that the area is composed of clay, sandy clay and sand. The contaminated zones have low resistivity and corresponding high conductivity. Two zones were identified, zones of low resistivity and high resistivity with values of 11.3 Ωm to 21.4 Ωm, and 357.0 Ωm to795.0 Ωm respectively. There is thus, both lateral and downward movement of the contaminant leachate plumes. The results also revealed that the  surrounding soil and groundwater around the landfill has not been contaminated to depths exceeding 15.6 m, which is shallower than the productive aquifer depth greater than 37.0 m. Judging from the age of the dumpsite, this site has a good protecting capacity, probably as a result of the presence of sufficient confined layers of clay that have impeded or slowed down the percolation of leachate into the aquifer. The aquifer is the underlying rocks of sand and gravel that are porous which constitute the water body. Keywords: Dumpsite, Resistivity, Sounding, Leachate, Aquifer.
first_indexed 2024-04-24T06:45:38Z
format Article
id doaj.art-99a35e079a1042568cac6b5bc99f2709
institution Directory Open Access Journal
issn 2659-1502
2659-1499
language English
last_indexed 2024-04-24T06:45:38Z
publishDate 2020-01-01
publisher Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP)
record_format Article
series Journal of Applied Sciences and Environmental Management
spelling doaj.art-99a35e079a1042568cac6b5bc99f27092024-04-22T19:46:12ZengJoint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP)Journal of Applied Sciences and Environmental Management2659-15022659-14992020-01-012312Vertical Electric Sounding of Leachate Contaminant Plumes at a Dumpsite in Obigbo, Rivers State, NigeriaW. TamunoS. Inichinbia The quality of underground water at a dumpsite in Obigbo, Rivers State, Nigeria, was investigated by collecting 7 vertical electrical soundings (VES) using Wenner electrode configuration with current electrode spacing (AB/2) ranging from 1.0 m to 300 m. Field data were acquired using the SAS 300C resistivity meter and accessories, coordinates and elevation were measured using the Global Positioning System (GPS) at each sounding station. The VES data showed that the area is composed of clay, sandy clay and sand. The contaminated zones have low resistivity and corresponding high conductivity. Two zones were identified, zones of low resistivity and high resistivity with values of 11.3 Ωm to 21.4 Ωm, and 357.0 Ωm to795.0 Ωm respectively. There is thus, both lateral and downward movement of the contaminant leachate plumes. The results also revealed that the  surrounding soil and groundwater around the landfill has not been contaminated to depths exceeding 15.6 m, which is shallower than the productive aquifer depth greater than 37.0 m. Judging from the age of the dumpsite, this site has a good protecting capacity, probably as a result of the presence of sufficient confined layers of clay that have impeded or slowed down the percolation of leachate into the aquifer. The aquifer is the underlying rocks of sand and gravel that are porous which constitute the water body. Keywords: Dumpsite, Resistivity, Sounding, Leachate, Aquifer. https://www.ajol.info/index.php/jasem/article/view/192549DumpsiteResistivitySoundingLeachateAquifer
spellingShingle W. Tamuno
S. Inichinbia
Vertical Electric Sounding of Leachate Contaminant Plumes at a Dumpsite in Obigbo, Rivers State, Nigeria
Journal of Applied Sciences and Environmental Management
Dumpsite
Resistivity
Sounding
Leachate
Aquifer
title Vertical Electric Sounding of Leachate Contaminant Plumes at a Dumpsite in Obigbo, Rivers State, Nigeria
title_full Vertical Electric Sounding of Leachate Contaminant Plumes at a Dumpsite in Obigbo, Rivers State, Nigeria
title_fullStr Vertical Electric Sounding of Leachate Contaminant Plumes at a Dumpsite in Obigbo, Rivers State, Nigeria
title_full_unstemmed Vertical Electric Sounding of Leachate Contaminant Plumes at a Dumpsite in Obigbo, Rivers State, Nigeria
title_short Vertical Electric Sounding of Leachate Contaminant Plumes at a Dumpsite in Obigbo, Rivers State, Nigeria
title_sort vertical electric sounding of leachate contaminant plumes at a dumpsite in obigbo rivers state nigeria
topic Dumpsite
Resistivity
Sounding
Leachate
Aquifer
url https://www.ajol.info/index.php/jasem/article/view/192549
work_keys_str_mv AT wtamuno verticalelectricsoundingofleachatecontaminantplumesatadumpsiteinobigboriversstatenigeria
AT sinichinbia verticalelectricsoundingofleachatecontaminantplumesatadumpsiteinobigboriversstatenigeria