Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in Dogs

Over-inflation of an endotracheal tube (ETT) cuff may lead to tracheal mucosal irritation, tracheal wall ischemia or necrosis, whereas under-inflation increases the risk of pulmonary aspiration as well as leaking anesthetic gas and polluting the environment. The objectives of this two-phase study we...

Full description

Bibliographic Details
Main Authors: Wan-Chu Hung, Jeff C. Ko, Ann B. Weil, Hsin-Yi Weng
Format: Article
Language:English
Published: Frontiers Media S.A. 2020-02-01
Series:Frontiers in Veterinary Science
Subjects:
Online Access:https://www.frontiersin.org/article/10.3389/fvets.2020.00039/full
_version_ 1828930945256783872
author Wan-Chu Hung
Jeff C. Ko
Ann B. Weil
Hsin-Yi Weng
author_facet Wan-Chu Hung
Jeff C. Ko
Ann B. Weil
Hsin-Yi Weng
author_sort Wan-Chu Hung
collection DOAJ
description Over-inflation of an endotracheal tube (ETT) cuff may lead to tracheal mucosal irritation, tracheal wall ischemia or necrosis, whereas under-inflation increases the risk of pulmonary aspiration as well as leaking anesthetic gas and polluting the environment. The objectives of this two-phase study were to (1) identify the incidence of improper ETT cuff inflation (both over- and under-inflation) using the minimum occlusive volume (MOV) technique coupled with a regular injectable syringe in the anesthetized dogs, and (2) evaluate the performance of two commercially available inflation syringe devices (Tru-Cuff and AG Cuffill®) with the regular injectable syringe in inflating the ETT cuff to a recommended safe cuff pressure range (20–30 cmH2O). Dogs undergoing general anesthesia at Purdue Veterinary Medicine Teaching Hospital were included. The ETT cuff pressure was assessed with an aneroid manometer after the syringe inflation. The results of the first objective showed that a total of 80 dogs enrolled and that 50 of these 80 dogs required ETT cuff inflation. Among the 50 dogs, only 14% had proper ETT cuff inflation; 76% of the ETT cuffs were over-inflated and 10% were under-inflated. Ninety dogs were enrolled for the second objective study and they were randomly and equally assigned to the three syringe device treatment groups. The results showed that 80% of the ETT cuffs were over-inflated in the regular injectable syringe treatment group, whereas only 6.7% and 3.3% ETT cuffs were over-inflated in the Tru-Cuff and AG Cuffill® syringe treatment groups, respectively. The AG Cuffill® syringe treatment group had a significantly (p < 0.05) higher percentage of properly inflated ETT cuffs (86.7%) compared to the other two groups (regular injectable syringe [3.3%]; Tru-Cuff syringe [50%]. We concluded that there was a high incidence of improper ETT cuff inflation when using MOV technique coupled with a regular injectable syringe. The use of an AG Cuffill® syringe significantly reduced improper ETT cuff inflation.
first_indexed 2024-12-14T00:39:28Z
format Article
id doaj.art-99ceaf32d36e42dbb5bb09b412e0f586
institution Directory Open Access Journal
issn 2297-1769
language English
last_indexed 2024-12-14T00:39:28Z
publishDate 2020-02-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Veterinary Science
spelling doaj.art-99ceaf32d36e42dbb5bb09b412e0f5862022-12-21T23:24:27ZengFrontiers Media S.A.Frontiers in Veterinary Science2297-17692020-02-01710.3389/fvets.2020.00039507329Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in DogsWan-Chu Hung0Jeff C. Ko1Ann B. Weil2Hsin-Yi Weng3Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, United StatesDepartment of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, United StatesDepartment of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, United StatesDepartment of Comparative Pathobiology, College of Veterinary Medicine, Purdue University, West Lafayette, IN, United StatesOver-inflation of an endotracheal tube (ETT) cuff may lead to tracheal mucosal irritation, tracheal wall ischemia or necrosis, whereas under-inflation increases the risk of pulmonary aspiration as well as leaking anesthetic gas and polluting the environment. The objectives of this two-phase study were to (1) identify the incidence of improper ETT cuff inflation (both over- and under-inflation) using the minimum occlusive volume (MOV) technique coupled with a regular injectable syringe in the anesthetized dogs, and (2) evaluate the performance of two commercially available inflation syringe devices (Tru-Cuff and AG Cuffill®) with the regular injectable syringe in inflating the ETT cuff to a recommended safe cuff pressure range (20–30 cmH2O). Dogs undergoing general anesthesia at Purdue Veterinary Medicine Teaching Hospital were included. The ETT cuff pressure was assessed with an aneroid manometer after the syringe inflation. The results of the first objective showed that a total of 80 dogs enrolled and that 50 of these 80 dogs required ETT cuff inflation. Among the 50 dogs, only 14% had proper ETT cuff inflation; 76% of the ETT cuffs were over-inflated and 10% were under-inflated. Ninety dogs were enrolled for the second objective study and they were randomly and equally assigned to the three syringe device treatment groups. The results showed that 80% of the ETT cuffs were over-inflated in the regular injectable syringe treatment group, whereas only 6.7% and 3.3% ETT cuffs were over-inflated in the Tru-Cuff and AG Cuffill® syringe treatment groups, respectively. The AG Cuffill® syringe treatment group had a significantly (p < 0.05) higher percentage of properly inflated ETT cuffs (86.7%) compared to the other two groups (regular injectable syringe [3.3%]; Tru-Cuff syringe [50%]. We concluded that there was a high incidence of improper ETT cuff inflation when using MOV technique coupled with a regular injectable syringe. The use of an AG Cuffill® syringe significantly reduced improper ETT cuff inflation.https://www.frontiersin.org/article/10.3389/fvets.2020.00039/fullendotracheal tube cuff pressureendotracheal tube cuff inflation deviceendotracheal tube cuff pressure monitoringendotracheal tube cuff pressure measurementdog
spellingShingle Wan-Chu Hung
Jeff C. Ko
Ann B. Weil
Hsin-Yi Weng
Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in Dogs
Frontiers in Veterinary Science
endotracheal tube cuff pressure
endotracheal tube cuff inflation device
endotracheal tube cuff pressure monitoring
endotracheal tube cuff pressure measurement
dog
title Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in Dogs
title_full Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in Dogs
title_fullStr Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in Dogs
title_full_unstemmed Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in Dogs
title_short Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in Dogs
title_sort evaluation of endotracheal tube cuff pressure and the use of three cuff inflation syringe devices in dogs
topic endotracheal tube cuff pressure
endotracheal tube cuff inflation device
endotracheal tube cuff pressure monitoring
endotracheal tube cuff pressure measurement
dog
url https://www.frontiersin.org/article/10.3389/fvets.2020.00039/full
work_keys_str_mv AT wanchuhung evaluationofendotrachealtubecuffpressureandtheuseofthreecuffinflationsyringedevicesindogs
AT jeffcko evaluationofendotrachealtubecuffpressureandtheuseofthreecuffinflationsyringedevicesindogs
AT annbweil evaluationofendotrachealtubecuffpressureandtheuseofthreecuffinflationsyringedevicesindogs
AT hsinyiweng evaluationofendotrachealtubecuffpressureandtheuseofthreecuffinflationsyringedevicesindogs