ANALYSIS OUTPUT TOLERANCE LIMITS X-RAY MACHINE DIAGNOSTIC (Case Study in one of the General Hospital inBanda Aceh)

Currently, several regional general hospitals in Banda Aceh now have excellent support facilities, one of which is a diagnostic X-ray machine. The performance of diagnostic X-ray machine should be checked to determine if the dose received does not harm a patient and produce a good image and provide...

Full description

Bibliographic Details
Main Authors: Evi Yuvita, Rini Safitri
Format: Article
Language:English
Published: Universitas Syiah Kuala, Faculty of Mathematics and Natural Science 2013-10-01
Series:Jurnal Natural
Online Access:http://www.jurnal.unsyiah.ac.id/natural/article/view/826
_version_ 1797229870278770688
author Evi Yuvita
Rini Safitri
author_facet Evi Yuvita
Rini Safitri
author_sort Evi Yuvita
collection DOAJ
description Currently, several regional general hospitals in Banda Aceh now have excellent support facilities, one of which is a diagnostic X-ray machine. The performance of diagnostic X-ray machine should be checked to determine if the dose received does not harm a patient and produce a good image and provide diagnostic information in a timely and accurate, therefore there are necessary for quality control activities on the machine X-ray. Factors that affect the dosing and imaging results, among others, the amount of the provision of current and voltage. From the research shows that the value of the output voltage generated is not much different from the value of the input voltage with a percentage value below 5%. This value shows a good output machineX-ray because it is still under the maximum tolerance limit of 10%. So the overall results of observations on the machineX-ray is in hospital, the quality control measurements gave values still within safe limits. Then by giving a higher input voltage turns also affect the amount of energy produced, thus affecting also absorbed dose X-rays are produced.
first_indexed 2024-04-24T15:19:27Z
format Article
id doaj.art-9a07b62e33fd4924ae6c6b9db5c8f434
institution Directory Open Access Journal
issn 1411-8513
2541-4062
language English
last_indexed 2024-04-24T15:19:27Z
publishDate 2013-10-01
publisher Universitas Syiah Kuala, Faculty of Mathematics and Natural Science
record_format Article
series Jurnal Natural
spelling doaj.art-9a07b62e33fd4924ae6c6b9db5c8f4342024-04-02T08:38:56ZengUniversitas Syiah Kuala, Faculty of Mathematics and Natural ScienceJurnal Natural1411-85132541-40622013-10-01121802ANALYSIS OUTPUT TOLERANCE LIMITS X-RAY MACHINE DIAGNOSTIC (Case Study in one of the General Hospital inBanda Aceh)Evi Yuvita0Rini Safitri1Physics Department, Faculty of Mathematics and Natural Sciences, Syiah Kuala UniversityPhysics Department, Faculty of Mathematics and Natural Sciences, Syiah Kuala UniversityCurrently, several regional general hospitals in Banda Aceh now have excellent support facilities, one of which is a diagnostic X-ray machine. The performance of diagnostic X-ray machine should be checked to determine if the dose received does not harm a patient and produce a good image and provide diagnostic information in a timely and accurate, therefore there are necessary for quality control activities on the machine X-ray. Factors that affect the dosing and imaging results, among others, the amount of the provision of current and voltage. From the research shows that the value of the output voltage generated is not much different from the value of the input voltage with a percentage value below 5%. This value shows a good output machineX-ray because it is still under the maximum tolerance limit of 10%. So the overall results of observations on the machineX-ray is in hospital, the quality control measurements gave values still within safe limits. Then by giving a higher input voltage turns also affect the amount of energy produced, thus affecting also absorbed dose X-rays are produced.http://www.jurnal.unsyiah.ac.id/natural/article/view/826
spellingShingle Evi Yuvita
Rini Safitri
ANALYSIS OUTPUT TOLERANCE LIMITS X-RAY MACHINE DIAGNOSTIC (Case Study in one of the General Hospital inBanda Aceh)
Jurnal Natural
title ANALYSIS OUTPUT TOLERANCE LIMITS X-RAY MACHINE DIAGNOSTIC (Case Study in one of the General Hospital inBanda Aceh)
title_full ANALYSIS OUTPUT TOLERANCE LIMITS X-RAY MACHINE DIAGNOSTIC (Case Study in one of the General Hospital inBanda Aceh)
title_fullStr ANALYSIS OUTPUT TOLERANCE LIMITS X-RAY MACHINE DIAGNOSTIC (Case Study in one of the General Hospital inBanda Aceh)
title_full_unstemmed ANALYSIS OUTPUT TOLERANCE LIMITS X-RAY MACHINE DIAGNOSTIC (Case Study in one of the General Hospital inBanda Aceh)
title_short ANALYSIS OUTPUT TOLERANCE LIMITS X-RAY MACHINE DIAGNOSTIC (Case Study in one of the General Hospital inBanda Aceh)
title_sort analysis output tolerance limits x ray machine diagnostic case study in one of the general hospital inbanda aceh
url http://www.jurnal.unsyiah.ac.id/natural/article/view/826
work_keys_str_mv AT eviyuvita analysisoutputtolerancelimitsxraymachinediagnosticcasestudyinoneofthegeneralhospitalinbandaaceh
AT rinisafitri analysisoutputtolerancelimitsxraymachinediagnosticcasestudyinoneofthegeneralhospitalinbandaaceh