Abstract Background To investigate changes in corneal elevation, pachymetry, and keratometry in discriminating between normal and blepharospasm eyes, as measured by the Pentacam rotating Scheimpflug camera. Methods This was a prospective, cross-sectional study. A total of 47 consecutive patients wit...

Full description

Bibliographic Details
Main Authors: Huina Zhang, Hongjie Zhou, Tiepei Zhu, Juan Ye
Format: Article
Language:English
Published: BMC 2018-09-01
Series:BMC Ophthalmology
Subjects:
Online Access:http://link.springer.com/article/10.1186/s12886-018-0897-9
_version_ 1819070841280790528
author Huina Zhang
Hongjie Zhou
Tiepei Zhu
Juan Ye
author_facet Huina Zhang
Hongjie Zhou
Tiepei Zhu
Juan Ye
author_sort Huina Zhang
collection DOAJ
description Abstract Background To investigate changes in corneal elevation, pachymetry, and keratometry in discriminating between normal and blepharospasm eyes, as measured by the Pentacam rotating Scheimpflug camera. Methods This was a prospective, cross-sectional study. A total of 47 consecutive patients with a range of blepharospasm severity and 40 age- and sex- matched healthy subjects were included, one eye of each subject was randomly chosen for data analysis. Blepharospasm severity was evaluated using the Jankovic scale and categorized as mild, moderate, or severe. Corneal parameters were measured by the Pentacam rotating Scheimpflug camera to derive corneal tomography information. Various parameters regarding keratometry, elevation at the anterior and posterior corneal surface, pachymetric data, final D value, and topometric indices from the Pentacam software were recorded, and the relationship between the blink rate and corneal parameters was analyzed. Intraclass correlation coefficients (ICCs) were assessed to evaluate the repeatability of intraobserver. Results Increased topographic asymmetry was observed in moderate and severe blepharospasm. Front K1and front Km were significantly higher in cases of mild (P < 0.05), moderate (P < 0.0001), and severe (P < 0.0001) blepharospasm as compared with controls. Front K2, back K1, back K2, and back Km were significantly higher in cases of moderate (P < 0.01) and severe (P < 0.001) blepharospasm as compared with controls. For corneal topometric indices, both ISV and IVA were significantly increased in severe blepharospasm (P < 0.05). Radii minimum were significantly increased in cases of moderate and severe blepharospasm (P < 0.05).There were no differences in corneal elevation and corneal pharcymetric parameters among the four groups, except for front BFS, which was significantly different in blepharospasm groups (P < 0.05). Final D values were significantly higher in the severe blepharospasm (P < 0.01) group than that among controls. There were significant correlations between the blink rate and most corneal tomographic parameters. All parameters showed high reproducibility (ICC: 0.921–0.996) for normal and blepharospasm subjects. Conclusions Blepharospasm may lead to a redistribution of the pressure applied by the lids over the cornea and, consequently, may result in corneal shape changes, which can be documented through corneal topography.
first_indexed 2024-12-21T17:12:21Z
format Article
id doaj.art-9a0d6592124743e199c54f70c0d54852
institution Directory Open Access Journal
issn 1471-2415
language English
last_indexed 2024-12-21T17:12:21Z
publishDate 2018-09-01
publisher BMC
record_format Article
series BMC Ophthalmology
spelling doaj.art-9a0d6592124743e199c54f70c0d548522022-12-21T18:56:22ZengBMCBMC Ophthalmology1471-24152018-09-011811810.1186/s12886-018-0897-9Evaluation of Scheimpflug imaging parameters in blepharospasm and normal eyesHuina Zhang0Hongjie Zhou1Tiepei Zhu2Juan Ye3Department of Ophthalmology, the Second Affiliated Hospital, Zhejiang University School of MedicineHangzhou Hospital for the Prevention and Treatment of Occupational DiseasesDepartment of Ophthalmology, the Second Affiliated Hospital, Zhejiang University School of MedicineDepartment of Ophthalmology, the Second Affiliated Hospital, Zhejiang University School of MedicineAbstract Background To investigate changes in corneal elevation, pachymetry, and keratometry in discriminating between normal and blepharospasm eyes, as measured by the Pentacam rotating Scheimpflug camera. Methods This was a prospective, cross-sectional study. A total of 47 consecutive patients with a range of blepharospasm severity and 40 age- and sex- matched healthy subjects were included, one eye of each subject was randomly chosen for data analysis. Blepharospasm severity was evaluated using the Jankovic scale and categorized as mild, moderate, or severe. Corneal parameters were measured by the Pentacam rotating Scheimpflug camera to derive corneal tomography information. Various parameters regarding keratometry, elevation at the anterior and posterior corneal surface, pachymetric data, final D value, and topometric indices from the Pentacam software were recorded, and the relationship between the blink rate and corneal parameters was analyzed. Intraclass correlation coefficients (ICCs) were assessed to evaluate the repeatability of intraobserver. Results Increased topographic asymmetry was observed in moderate and severe blepharospasm. Front K1and front Km were significantly higher in cases of mild (P < 0.05), moderate (P < 0.0001), and severe (P < 0.0001) blepharospasm as compared with controls. Front K2, back K1, back K2, and back Km were significantly higher in cases of moderate (P < 0.01) and severe (P < 0.001) blepharospasm as compared with controls. For corneal topometric indices, both ISV and IVA were significantly increased in severe blepharospasm (P < 0.05). Radii minimum were significantly increased in cases of moderate and severe blepharospasm (P < 0.05).There were no differences in corneal elevation and corneal pharcymetric parameters among the four groups, except for front BFS, which was significantly different in blepharospasm groups (P < 0.05). Final D values were significantly higher in the severe blepharospasm (P < 0.01) group than that among controls. There were significant correlations between the blink rate and most corneal tomographic parameters. All parameters showed high reproducibility (ICC: 0.921–0.996) for normal and blepharospasm subjects. Conclusions Blepharospasm may lead to a redistribution of the pressure applied by the lids over the cornea and, consequently, may result in corneal shape changes, which can be documented through corneal topography.http://link.springer.com/article/10.1186/s12886-018-0897-9Blepharospasm, Pentacam, Corneal curvature Corneal topography
spellingShingle Huina Zhang
Hongjie Zhou
Tiepei Zhu
Juan Ye
Evaluation of Scheimpflug imaging parameters in blepharospasm and normal eyes
BMC Ophthalmology
Blepharospasm, Pentacam, Corneal curvature Corneal topography
title Evaluation of Scheimpflug imaging parameters in blepharospasm and normal eyes
title_full Evaluation of Scheimpflug imaging parameters in blepharospasm and normal eyes
title_fullStr Evaluation of Scheimpflug imaging parameters in blepharospasm and normal eyes
title_full_unstemmed Evaluation of Scheimpflug imaging parameters in blepharospasm and normal eyes
title_short Evaluation of Scheimpflug imaging parameters in blepharospasm and normal eyes
title_sort evaluation of scheimpflug imaging parameters in blepharospasm and normal eyes
topic Blepharospasm, Pentacam, Corneal curvature Corneal topography
url http://link.springer.com/article/10.1186/s12886-018-0897-9
work_keys_str_mv AT huinazhang evaluationofscheimpflugimagingparametersinblepharospasmandnormaleyes
AT hongjiezhou evaluationofscheimpflugimagingparametersinblepharospasmandnormaleyes
AT tiepeizhu evaluationofscheimpflugimagingparametersinblepharospasmandnormaleyes
AT juanye evaluationofscheimpflugimagingparametersinblepharospasmandnormaleyes