Considerable cracking in the foundation slab in a multi-storey underground garage

Multilevel underground garages are often an ambitious geotechnical task in urban agglomeration. Lower levels of foundation slabs are often located below the groundwater level, which requires effective protection of the structure against groundwater invasion. The constructor’s task is to design slabs...

Full description

Bibliographic Details
Main Authors: Maj Marek, Tamrazyan Ashot, Ubysz Andrzej
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2019/33/matecconf_icsf2019_06003.pdf
_version_ 1818398284662702080
author Maj Marek
Tamrazyan Ashot
Ubysz Andrzej
author_facet Maj Marek
Tamrazyan Ashot
Ubysz Andrzej
author_sort Maj Marek
collection DOAJ
description Multilevel underground garages are often an ambitious geotechnical task in urban agglomeration. Lower levels of foundation slabs are often located below the groundwater level, which requires effective protection of the structure against groundwater invasion. The constructor’s task is to design slabs and walls so that no cracks will form to allow groundwater infiltration. In practice, this requires the development of a correct recipe for concrete; moreover, all factors affecting the total state of normal and tangential stresses as well as technologies allowing for correct execution of the facility must be considered. Additionally, long-term destructive factors ought to be taken into account. The article presents problems that arose during the use of an underground garage, which occurred as a result of failure to take into account at the design stage some rheological processes, as well as the assessment of the possibility of using the facility despite the damage.
first_indexed 2024-12-14T07:02:21Z
format Article
id doaj.art-9a5822f1682b4b5b82c5d1d61d47d6a4
institution Directory Open Access Journal
issn 2261-236X
language English
last_indexed 2024-12-14T07:02:21Z
publishDate 2019-01-01
publisher EDP Sciences
record_format Article
series MATEC Web of Conferences
spelling doaj.art-9a5822f1682b4b5b82c5d1d61d47d6a42022-12-21T23:12:24ZengEDP SciencesMATEC Web of Conferences2261-236X2019-01-012840600310.1051/matecconf/201928406003matecconf_icsf2019_06003Considerable cracking in the foundation slab in a multi-storey underground garageMaj Marek0Tamrazyan Ashot1Ubysz Andrzej2Wroclaw University of Science and TechnologyMoscow State University of Civil EngineeringWroclaw University of Science and TechnologyMultilevel underground garages are often an ambitious geotechnical task in urban agglomeration. Lower levels of foundation slabs are often located below the groundwater level, which requires effective protection of the structure against groundwater invasion. The constructor’s task is to design slabs and walls so that no cracks will form to allow groundwater infiltration. In practice, this requires the development of a correct recipe for concrete; moreover, all factors affecting the total state of normal and tangential stresses as well as technologies allowing for correct execution of the facility must be considered. Additionally, long-term destructive factors ought to be taken into account. The article presents problems that arose during the use of an underground garage, which occurred as a result of failure to take into account at the design stage some rheological processes, as well as the assessment of the possibility of using the facility despite the damage.https://www.matec-conferences.org/articles/matecconf/pdf/2019/33/matecconf_icsf2019_06003.pdf
spellingShingle Maj Marek
Tamrazyan Ashot
Ubysz Andrzej
Considerable cracking in the foundation slab in a multi-storey underground garage
MATEC Web of Conferences
title Considerable cracking in the foundation slab in a multi-storey underground garage
title_full Considerable cracking in the foundation slab in a multi-storey underground garage
title_fullStr Considerable cracking in the foundation slab in a multi-storey underground garage
title_full_unstemmed Considerable cracking in the foundation slab in a multi-storey underground garage
title_short Considerable cracking in the foundation slab in a multi-storey underground garage
title_sort considerable cracking in the foundation slab in a multi storey underground garage
url https://www.matec-conferences.org/articles/matecconf/pdf/2019/33/matecconf_icsf2019_06003.pdf
work_keys_str_mv AT majmarek considerablecrackinginthefoundationslabinamultistoreyundergroundgarage
AT tamrazyanashot considerablecrackinginthefoundationslabinamultistoreyundergroundgarage
AT ubyszandrzej considerablecrackinginthefoundationslabinamultistoreyundergroundgarage