Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study

BackgroundInferior vena cava (IVC) ultrasonography is a reliable variable that predicts post-induction hypotension (PIH) in patients undergoing surgery under general anesthesia. However, in patients with hypertension, the predictive performance of ultrasound IVC measurements needs further exploratio...

Full description

Bibliographic Details
Main Authors: Hanying Zhang, Hongguang Gao, Yuanjun Xiang, Junxiang Li
Format: Article
Language:English
Published: Frontiers Media S.A. 2022-10-01
Series:Frontiers in Cardiovascular Medicine
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fcvm.2022.958259/full
_version_ 1811242849334722560
author Hanying Zhang
Hongguang Gao
Yuanjun Xiang
Junxiang Li
author_facet Hanying Zhang
Hongguang Gao
Yuanjun Xiang
Junxiang Li
author_sort Hanying Zhang
collection DOAJ
description BackgroundInferior vena cava (IVC) ultrasonography is a reliable variable that predicts post-induction hypotension (PIH) in patients undergoing surgery under general anesthesia. However, in patients with hypertension, the predictive performance of ultrasound IVC measurements needs further exploration.MethodsThis is a prospective cohort study. Adult patients with existing hypertension scheduled to undergo non-cardiac surgery under general anesthesia were eligible. An abdominal ultrasound examination was conducted immediately prior to anesthesia induction (0.03 mg kg–1 midazolam, 0.3 mg kg–1 etomidate, 0.4 μg kg–1 sufentanil, and 0.6 mg kg–1 rocuronium). IVC collapsibility index (IVC-CI) was calculated as (dIVCmax–dIVCmin)/dIVCmax, where dIVCmax and dIVCmin represent the maximum and minimum IVC diameters at the end of expiration and inspiration, respectively. PIH was defined as a reduction of mean arterial pressure (MAP) by >30% of the baseline or to <60 mmHg within 10 min after endotracheal intubation. The diagnostic performance of IVC-CI, dIVCmax, and dIVCmin in predicting PIH was also examined in a group of normotensive patients receiving non-cardiac surgery under the same anesthesia protocol.ResultsA total of 51 hypertensive patients (61 ± 13 years of age, 31 women) and 52 normotensive patients (42 ± 13 years of age, 35 women) were included in the final analysis. PIH occurred in 33 (64.7%) hypertensive patients and 19 (36.5%) normotensive patients. In normotensive patients, the area under the receiver operating curve (AUC) in predicting PIH was 0.896 (95% confidence interval [CI]: 0.804–0.987) for IVC-CI, 0.770 (95% CI: 0.633–0.908) for dIVCmax, and 0.868 (95% CI: 0.773–0.963) for dIVCmin. In hypertensive patients, the AUC in predicting PIH was 0.523 (95% CI: 0.354–0.691) for IVC-CI, 0.752 (95% CI: 0.621–0.883) for dIVCmax, and 0.715 (95% CI: 0.571–0.858) for dIVCmin. At the optimal cutoff (1.24 cm), dIVCmax had 54.5% (18/33) sensitivity and 94.4% (17/18) specificity.ConclusionIn hypertensive patients, IVC-CI is unsuitable for predicting PIH, and dIVCmax is an alternative measure with promising performance.Clinical trial registration[http://www.chictr.org.cn/], identifier [ChiCTR2000034853].
first_indexed 2024-04-12T13:57:10Z
format Article
id doaj.art-9acba72b2d8d4427bf41df3700b836fc
institution Directory Open Access Journal
issn 2297-055X
language English
last_indexed 2024-04-12T13:57:10Z
publishDate 2022-10-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Cardiovascular Medicine
spelling doaj.art-9acba72b2d8d4427bf41df3700b836fc2022-12-22T03:30:20ZengFrontiers Media S.A.Frontiers in Cardiovascular Medicine2297-055X2022-10-01910.3389/fcvm.2022.958259958259Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort studyHanying ZhangHongguang GaoYuanjun XiangJunxiang LiBackgroundInferior vena cava (IVC) ultrasonography is a reliable variable that predicts post-induction hypotension (PIH) in patients undergoing surgery under general anesthesia. However, in patients with hypertension, the predictive performance of ultrasound IVC measurements needs further exploration.MethodsThis is a prospective cohort study. Adult patients with existing hypertension scheduled to undergo non-cardiac surgery under general anesthesia were eligible. An abdominal ultrasound examination was conducted immediately prior to anesthesia induction (0.03 mg kg–1 midazolam, 0.3 mg kg–1 etomidate, 0.4 μg kg–1 sufentanil, and 0.6 mg kg–1 rocuronium). IVC collapsibility index (IVC-CI) was calculated as (dIVCmax–dIVCmin)/dIVCmax, where dIVCmax and dIVCmin represent the maximum and minimum IVC diameters at the end of expiration and inspiration, respectively. PIH was defined as a reduction of mean arterial pressure (MAP) by >30% of the baseline or to <60 mmHg within 10 min after endotracheal intubation. The diagnostic performance of IVC-CI, dIVCmax, and dIVCmin in predicting PIH was also examined in a group of normotensive patients receiving non-cardiac surgery under the same anesthesia protocol.ResultsA total of 51 hypertensive patients (61 ± 13 years of age, 31 women) and 52 normotensive patients (42 ± 13 years of age, 35 women) were included in the final analysis. PIH occurred in 33 (64.7%) hypertensive patients and 19 (36.5%) normotensive patients. In normotensive patients, the area under the receiver operating curve (AUC) in predicting PIH was 0.896 (95% confidence interval [CI]: 0.804–0.987) for IVC-CI, 0.770 (95% CI: 0.633–0.908) for dIVCmax, and 0.868 (95% CI: 0.773–0.963) for dIVCmin. In hypertensive patients, the AUC in predicting PIH was 0.523 (95% CI: 0.354–0.691) for IVC-CI, 0.752 (95% CI: 0.621–0.883) for dIVCmax, and 0.715 (95% CI: 0.571–0.858) for dIVCmin. At the optimal cutoff (1.24 cm), dIVCmax had 54.5% (18/33) sensitivity and 94.4% (17/18) specificity.ConclusionIn hypertensive patients, IVC-CI is unsuitable for predicting PIH, and dIVCmax is an alternative measure with promising performance.Clinical trial registration[http://www.chictr.org.cn/], identifier [ChiCTR2000034853].https://www.frontiersin.org/articles/10.3389/fcvm.2022.958259/fullgeneral anesthesiahypertensioninferior vena cavapost-induction hypotensionultrasound
spellingShingle Hanying Zhang
Hongguang Gao
Yuanjun Xiang
Junxiang Li
Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study
Frontiers in Cardiovascular Medicine
general anesthesia
hypertension
inferior vena cava
post-induction hypotension
ultrasound
title Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study
title_full Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study
title_fullStr Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study
title_full_unstemmed Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study
title_short Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study
title_sort maximum inferior vena cava diameter predicts post induction hypotension in hypertensive patients undergoing non cardiac surgery under general anesthesia a prospective cohort study
topic general anesthesia
hypertension
inferior vena cava
post-induction hypotension
ultrasound
url https://www.frontiersin.org/articles/10.3389/fcvm.2022.958259/full
work_keys_str_mv AT hanyingzhang maximuminferiorvenacavadiameterpredictspostinductionhypotensioninhypertensivepatientsundergoingnoncardiacsurgeryundergeneralanesthesiaaprospectivecohortstudy
AT hongguanggao maximuminferiorvenacavadiameterpredictspostinductionhypotensioninhypertensivepatientsundergoingnoncardiacsurgeryundergeneralanesthesiaaprospectivecohortstudy
AT yuanjunxiang maximuminferiorvenacavadiameterpredictspostinductionhypotensioninhypertensivepatientsundergoingnoncardiacsurgeryundergeneralanesthesiaaprospectivecohortstudy
AT junxiangli maximuminferiorvenacavadiameterpredictspostinductionhypotensioninhypertensivepatientsundergoingnoncardiacsurgeryundergeneralanesthesiaaprospectivecohortstudy