A Simplified Fluoroscopic Method for Commissural Alignment Assessment With a Balloon-Expandable Transcatheter Heart Valve

We sought to assess commissural alignment of the balloon-expandable valve on fluoroscopy. Commissural alignment was defined on fluoroscopy in 20 patients according to alignment of the valve commissural posts in the 3-cusp and the cusp-overlap view and correlated with post–transcatheter aortic valve...

Ful tanımlama

Detaylı Bibliyografya
Asıl Yazarlar: Mariama Akodad, MD, PhD, David Meier, MD, Georgios Tzimas, MD, Jonathon Leipsic, MD, Philipp Blanke, MD, David A. Wood, MD, John G. Webb, MD, Janarthanan Sathananthan, MB ChB, MD
Materyal Türü: Makale
Dil:English
Baskı/Yayın Bilgisi: Elsevier 2023-05-01
Seri Bilgileri:JACC: Case Reports
Konular:
Online Erişim:http://www.sciencedirect.com/science/article/pii/S2666084923000803