Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power Plants

A tuned mass damper (TMD) was developed for mitigating the seismic responses of electrical equipment inside nuclear power plants (NPPs), in particular, the response of an electrical cabinet. A shaking table test was performed, and the frequency and damping ratio were extracted, to confirm the dynami...

Full description

Bibliographic Details
Main Authors: Sung Gook Cho, Seongkyu Chang, Deokyong Sung
Format: Article
Language:English
Published: MDPI AG 2020-01-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/2/427
_version_ 1811187142483771392
author Sung Gook Cho
Seongkyu Chang
Deokyong Sung
author_facet Sung Gook Cho
Seongkyu Chang
Deokyong Sung
author_sort Sung Gook Cho
collection DOAJ
description A tuned mass damper (TMD) was developed for mitigating the seismic responses of electrical equipment inside nuclear power plants (NPPs), in particular, the response of an electrical cabinet. A shaking table test was performed, and the frequency and damping ratio were extracted, to confirm the dynamics of the cabinet. Electrical cabinets with and without TMDs were modeled while using SAP2000 software (Version 20, Computers and Structures, NY, USA) that was based on the results. TMDs were designed while using an optimization method and the equations of Den Hartog, Warburton, and Sadek. The numerical models were verified while using the shaking table test results. A sinusoidal sweep wave was applied as input to identify the vibration characteristics of the electrical cabinet over a wide frequency range. Applying various seismic loads that were adjusted to meet the RG 1.60 design response spectrum of 0.3 g then validated the control performance of the TMD. The minimum and maximum response spectrum reduction rates of the designed TMDs were 44.7% and 62.9%, respectively. Further, the amplification factor of the electrical cabinet with the TMD was decreased by 53%, on average, with the proposed optimization method. In conclusion, TMDs can be considered to be an effective way of enhancing the seismic performance of the electrical equipment inside NPPs.
first_indexed 2024-04-11T13:57:15Z
format Article
id doaj.art-9afc9f32c2f049b1821c5c1da199bb5d
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-11T13:57:15Z
publishDate 2020-01-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-9afc9f32c2f049b1821c5c1da199bb5d2022-12-22T04:20:13ZengMDPI AGEnergies1996-10732020-01-0113242710.3390/en13020427en13020427Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power PlantsSung Gook Cho0Seongkyu Chang1Deokyong Sung2R&D Center, Innose Tech Co., Ltd., 30 Songdomirae-ro, Yeonsu-gu, Incheon 21990, KoreaAcademic-Industry Cooperation Foundation, Kunsan National University, 558 Daehak-ro, Gunsan-si 54150, KoreaDepartment of Civil & Railroad Engineering, Daewon University College, 316 Daehak-ro, Jecheon, Chung-Buk 27135, KoreaA tuned mass damper (TMD) was developed for mitigating the seismic responses of electrical equipment inside nuclear power plants (NPPs), in particular, the response of an electrical cabinet. A shaking table test was performed, and the frequency and damping ratio were extracted, to confirm the dynamics of the cabinet. Electrical cabinets with and without TMDs were modeled while using SAP2000 software (Version 20, Computers and Structures, NY, USA) that was based on the results. TMDs were designed while using an optimization method and the equations of Den Hartog, Warburton, and Sadek. The numerical models were verified while using the shaking table test results. A sinusoidal sweep wave was applied as input to identify the vibration characteristics of the electrical cabinet over a wide frequency range. Applying various seismic loads that were adjusted to meet the RG 1.60 design response spectrum of 0.3 g then validated the control performance of the TMD. The minimum and maximum response spectrum reduction rates of the designed TMDs were 44.7% and 62.9%, respectively. Further, the amplification factor of the electrical cabinet with the TMD was decreased by 53%, on average, with the proposed optimization method. In conclusion, TMDs can be considered to be an effective way of enhancing the seismic performance of the electrical equipment inside NPPs.https://www.mdpi.com/1996-1073/13/2/427nuclear power plantelectrical cabinettuned mass damperoptimization methodseismic performance
spellingShingle Sung Gook Cho
Seongkyu Chang
Deokyong Sung
Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power Plants
Energies
nuclear power plant
electrical cabinet
tuned mass damper
optimization method
seismic performance
title Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power Plants
title_full Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power Plants
title_fullStr Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power Plants
title_full_unstemmed Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power Plants
title_short Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power Plants
title_sort application of tuned mass damper to mitigation of the seismic responses of electrical equipment in nuclear power plants
topic nuclear power plant
electrical cabinet
tuned mass damper
optimization method
seismic performance
url https://www.mdpi.com/1996-1073/13/2/427
work_keys_str_mv AT sunggookcho applicationoftunedmassdampertomitigationoftheseismicresponsesofelectricalequipmentinnuclearpowerplants
AT seongkyuchang applicationoftunedmassdampertomitigationoftheseismicresponsesofelectricalequipmentinnuclearpowerplants
AT deokyongsung applicationoftunedmassdampertomitigationoftheseismicresponsesofelectricalequipmentinnuclearpowerplants