Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.

We determined reliability of cardiac output (CO) measured by pulse wave transit time cardiac output system (esCCO system; COesCCO) vs transthoracic echocardiography (COTTE) in mechanically ventilated patients in the early phase of septic shock. A secondary objective was to assess ability of esCCO to...

Full description

Bibliographic Details
Main Authors: Marc Feissel, Ludwig Serge Aho, Stefan Georgiev, Romain Tapponnier, Julio Badie, Rémi Bruyère, Jean-Pierre Quenot
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2015-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4488420?pdf=render
_version_ 1819291489849573376
author Marc Feissel
Ludwig Serge Aho
Stefan Georgiev
Romain Tapponnier
Julio Badie
Rémi Bruyère
Jean-Pierre Quenot
author_facet Marc Feissel
Ludwig Serge Aho
Stefan Georgiev
Romain Tapponnier
Julio Badie
Rémi Bruyère
Jean-Pierre Quenot
author_sort Marc Feissel
collection DOAJ
description We determined reliability of cardiac output (CO) measured by pulse wave transit time cardiac output system (esCCO system; COesCCO) vs transthoracic echocardiography (COTTE) in mechanically ventilated patients in the early phase of septic shock. A secondary objective was to assess ability of esCCO to detect change in CO after fluid infusion.Mechanically ventilated patients admitted to the ICU, aged >18 years, in sinus rhythm, in the early phase of septic shock were prospectively included. We performed fluid infusion of 500 ml of crystalloid solution over 20 minutes and recorded CO by EsCCO and TTE immediately before (T0) and 5 minutes after (T1) fluid administration. Patients were divided into 2 groups (responders and non-responders) according to a threshold of 15% increase in COTTE in response to volume expansion.In total, 25 patients were included, average 64±15 years, 15 (60%) were men. Average SAPSII and SOFA scores were 55±21.3 and 13±2, respectively. ICU mortality was 36%. Mean cardiac output at T0 was 5.8±1.35 L/min by esCCO and 5.27±1.17 L/min by COTTE. At T1, respective values were 6.63 ± 1.57 L/min for esCCO and 6.10±1.29 L/min for COTTE. Overall, 12 patients were classified as responders, 13 as non-responders by the reference method. A threshold of 11% increase in COesCCO was found to discriminate responders from non-responders with a sensitivity of 83% (95% CI, 0.52-0.98) and a specificity of 77% (95% CI, 0.46-0.95).We show strong correlation esCCO and echocardiography for measuring CO, and change in CO after fluid infusion in ICU patients.
first_indexed 2024-12-24T03:39:27Z
format Article
id doaj.art-9b111cb3380f4e7ebaa23dc4c16d95da
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-24T03:39:27Z
publishDate 2015-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-9b111cb3380f4e7ebaa23dc4c16d95da2022-12-21T17:16:57ZengPublic Library of Science (PLoS)PLoS ONE1932-62032015-01-01106e013048910.1371/journal.pone.0130489Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.Marc FeisselLudwig Serge AhoStefan GeorgievRomain TapponnierJulio BadieRémi BruyèreJean-Pierre QuenotWe determined reliability of cardiac output (CO) measured by pulse wave transit time cardiac output system (esCCO system; COesCCO) vs transthoracic echocardiography (COTTE) in mechanically ventilated patients in the early phase of septic shock. A secondary objective was to assess ability of esCCO to detect change in CO after fluid infusion.Mechanically ventilated patients admitted to the ICU, aged >18 years, in sinus rhythm, in the early phase of septic shock were prospectively included. We performed fluid infusion of 500 ml of crystalloid solution over 20 minutes and recorded CO by EsCCO and TTE immediately before (T0) and 5 minutes after (T1) fluid administration. Patients were divided into 2 groups (responders and non-responders) according to a threshold of 15% increase in COTTE in response to volume expansion.In total, 25 patients were included, average 64±15 years, 15 (60%) were men. Average SAPSII and SOFA scores were 55±21.3 and 13±2, respectively. ICU mortality was 36%. Mean cardiac output at T0 was 5.8±1.35 L/min by esCCO and 5.27±1.17 L/min by COTTE. At T1, respective values were 6.63 ± 1.57 L/min for esCCO and 6.10±1.29 L/min for COTTE. Overall, 12 patients were classified as responders, 13 as non-responders by the reference method. A threshold of 11% increase in COesCCO was found to discriminate responders from non-responders with a sensitivity of 83% (95% CI, 0.52-0.98) and a specificity of 77% (95% CI, 0.46-0.95).We show strong correlation esCCO and echocardiography for measuring CO, and change in CO after fluid infusion in ICU patients.http://europepmc.org/articles/PMC4488420?pdf=render
spellingShingle Marc Feissel
Ludwig Serge Aho
Stefan Georgiev
Romain Tapponnier
Julio Badie
Rémi Bruyère
Jean-Pierre Quenot
Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.
PLoS ONE
title Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.
title_full Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.
title_fullStr Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.
title_full_unstemmed Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.
title_short Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.
title_sort pulse wave transit time measurements of cardiac output in septic shock patients a comparison of the estimated continuous cardiac output system with transthoracic echocardiography
url http://europepmc.org/articles/PMC4488420?pdf=render
work_keys_str_mv AT marcfeissel pulsewavetransittimemeasurementsofcardiacoutputinsepticshockpatientsacomparisonoftheestimatedcontinuouscardiacoutputsystemwithtransthoracicechocardiography
AT ludwigsergeaho pulsewavetransittimemeasurementsofcardiacoutputinsepticshockpatientsacomparisonoftheestimatedcontinuouscardiacoutputsystemwithtransthoracicechocardiography
AT stefangeorgiev pulsewavetransittimemeasurementsofcardiacoutputinsepticshockpatientsacomparisonoftheestimatedcontinuouscardiacoutputsystemwithtransthoracicechocardiography
AT romaintapponnier pulsewavetransittimemeasurementsofcardiacoutputinsepticshockpatientsacomparisonoftheestimatedcontinuouscardiacoutputsystemwithtransthoracicechocardiography
AT juliobadie pulsewavetransittimemeasurementsofcardiacoutputinsepticshockpatientsacomparisonoftheestimatedcontinuouscardiacoutputsystemwithtransthoracicechocardiography
AT remibruyere pulsewavetransittimemeasurementsofcardiacoutputinsepticshockpatientsacomparisonoftheestimatedcontinuouscardiacoutputsystemwithtransthoracicechocardiography
AT jeanpierrequenot pulsewavetransittimemeasurementsofcardiacoutputinsepticshockpatientsacomparisonoftheestimatedcontinuouscardiacoutputsystemwithtransthoracicechocardiography