Comparative analysis of Han and Uygur college students emmetropia biology measurement

AIM: To observe the differences in central cornea thickness, anterior chamber depth, corneal anterior curvature and corneal posterior curvature between the Uygur and the Han nationality college emmetropia students, and analyze the relationship of corneal thickness and corneal curvature.<p>METH...

Full description

Bibliographic Details
Main Authors: Meng Liu, Yan Wang, Ning Guo
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2014-10-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://www.ies.net.cn/cn_publish/2014/10/201410030.pdf
_version_ 1819012337976213504
author Meng Liu
Yan Wang
Ning Guo
author_facet Meng Liu
Yan Wang
Ning Guo
author_sort Meng Liu
collection DOAJ
description AIM: To observe the differences in central cornea thickness, anterior chamber depth, corneal anterior curvature and corneal posterior curvature between the Uygur and the Han nationality college emmetropia students, and analyze the relationship of corneal thickness and corneal curvature.<p>METHODS: More than 500 students in grade one in Xinjiang Medical University were underwent screening, 56 emmetropia eyes in Han nationality students and 51 in Uygur students were selected. Sirius corneal topography was applied to the measurement.<p>RESULTS:Uygur and the Han nationality college emmetropia students central cornea thickness(Uygur: 0.53±0.03mm, Han: 0.54±0.03mm), anterior chamber depth(Uygur: 2.91±0.26mm, Han: 3.14±0.25mm), corneal posterior curvature K2(Uygur: -6.30±0.23D, Han: -6.38±0.28D)had significant difference(<i>P</i><0.05). Corneal anterior curvature(K1, K2)before and corneal posterior curvature K1 there was no significant difference(<i>P</i>>0.05). Han had no significant relationship in corneal thickness and corneal anterior curvature(<i>r</i><0), or in corneal posterior curvature(<i>r</i><1). Uygur has no significant relationship in corneal thickness and corneal anterior curvature(<i>r</i><0), or in corneal posterior curvature(<i>r</i><1).<p>CONCLUSION: There are significant differences between the Uygur and the Han nationality college emmetropia students in cornea thickness, anterior chamber depth and corneal posterior curvature K2. There is no significant relationship between corneal thickness and corneal curvature in Uygur and the Han nationality college students.
first_indexed 2024-12-21T01:42:27Z
format Article
id doaj.art-9b19082a301e4a738d1fcdcdf10dccda
institution Directory Open Access Journal
issn 1672-5123
1672-5123
language English
last_indexed 2024-12-21T01:42:27Z
publishDate 2014-10-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series Guoji Yanke Zazhi
spelling doaj.art-9b19082a301e4a738d1fcdcdf10dccda2022-12-21T19:20:07ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232014-10-0114101846184810.3980/j.issn.1672-5123.2014.10.30Comparative analysis of Han and Uygur college students emmetropia biology measurementMeng Liu0Yan Wang1Ning Guo2Department of Ophthalmology, the Fourth Affiliated Hospital of Xinjiang Medical University, Urumqi 830000, Xinjiang Uygur Autonomous Region, ChinaDepartment of Ophthalmology, the Fourth Affiliated Hospital of Xinjiang Medical University, Urumqi 830000, Xinjiang Uygur Autonomous Region, ChinaDepartment of Ophthalmology, the Fourth Affiliated Hospital of Xinjiang Medical University, Urumqi 830000, Xinjiang Uygur Autonomous Region, ChinaAIM: To observe the differences in central cornea thickness, anterior chamber depth, corneal anterior curvature and corneal posterior curvature between the Uygur and the Han nationality college emmetropia students, and analyze the relationship of corneal thickness and corneal curvature.<p>METHODS: More than 500 students in grade one in Xinjiang Medical University were underwent screening, 56 emmetropia eyes in Han nationality students and 51 in Uygur students were selected. Sirius corneal topography was applied to the measurement.<p>RESULTS:Uygur and the Han nationality college emmetropia students central cornea thickness(Uygur: 0.53±0.03mm, Han: 0.54±0.03mm), anterior chamber depth(Uygur: 2.91±0.26mm, Han: 3.14±0.25mm), corneal posterior curvature K2(Uygur: -6.30±0.23D, Han: -6.38±0.28D)had significant difference(<i>P</i><0.05). Corneal anterior curvature(K1, K2)before and corneal posterior curvature K1 there was no significant difference(<i>P</i>>0.05). Han had no significant relationship in corneal thickness and corneal anterior curvature(<i>r</i><0), or in corneal posterior curvature(<i>r</i><1). Uygur has no significant relationship in corneal thickness and corneal anterior curvature(<i>r</i><0), or in corneal posterior curvature(<i>r</i><1).<p>CONCLUSION: There are significant differences between the Uygur and the Han nationality college emmetropia students in cornea thickness, anterior chamber depth and corneal posterior curvature K2. There is no significant relationship between corneal thickness and corneal curvature in Uygur and the Han nationality college students.http://www.ies.net.cn/cn_publish/2014/10/201410030.pdfcorneal curvaturecorneal thicknessanterior chamber depthcorneal topography
spellingShingle Meng Liu
Yan Wang
Ning Guo
Comparative analysis of Han and Uygur college students emmetropia biology measurement
Guoji Yanke Zazhi
corneal curvature
corneal thickness
anterior chamber depth
corneal topography
title Comparative analysis of Han and Uygur college students emmetropia biology measurement
title_full Comparative analysis of Han and Uygur college students emmetropia biology measurement
title_fullStr Comparative analysis of Han and Uygur college students emmetropia biology measurement
title_full_unstemmed Comparative analysis of Han and Uygur college students emmetropia biology measurement
title_short Comparative analysis of Han and Uygur college students emmetropia biology measurement
title_sort comparative analysis of han and uygur college students emmetropia biology measurement
topic corneal curvature
corneal thickness
anterior chamber depth
corneal topography
url http://www.ies.net.cn/cn_publish/2014/10/201410030.pdf
work_keys_str_mv AT mengliu comparativeanalysisofhananduygurcollegestudentsemmetropiabiologymeasurement
AT yanwang comparativeanalysisofhananduygurcollegestudentsemmetropiabiologymeasurement
AT ningguo comparativeanalysisofhananduygurcollegestudentsemmetropiabiologymeasurement