Highly Sensitive Twin Resonance Coupling Refractive Index Sensor Based on Gold- and MgF<sub>2</sub>-Coated Nano Metal Films

A plasmonic material-coated circular-shaped photonic crystal fiber (C-PCF) sensor based on surface plasmon resonance (SPR) is proposed to explore the optical guiding performance of the refractive index (RI) sensing at 1.7–3.7 <inline-formula>μ</inline-formula>m. A twin resonance coupling...

Full description

Bibliographic Details
Main Authors: Kawsar Ahmed, Mohammed A. AlZain, Hasan Abdullah, Yanhua Luo, Dhasarathan Vigneswaran, Osama S. Faragallah, Mahmoud M. A. Eid, Ahmed Nabih Zaki Rashed
Format: Article
Language:English
Published: MDPI AG 2021-04-01
Series:Biosensors
Subjects:
Online Access:https://www.mdpi.com/2079-6374/11/4/104
Description
Summary:A plasmonic material-coated circular-shaped photonic crystal fiber (C-PCF) sensor based on surface plasmon resonance (SPR) is proposed to explore the optical guiding performance of the refractive index (RI) sensing at 1.7–3.7 <inline-formula>μ</inline-formula>m. A twin resonance coupling profile is observed by selectively infiltrating liquid using finite element method (FEM). A nano-ring gold layer with a magnesium fluoride (MgF<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mn>2</mn></msub></semantics></math></inline-formula>) coating and fused silica are used as plasmonic and base material, respectively, that help to achieve maximum sensing performance. RI analytes are highly sensitive to SPR and are injected into the outmost air holes of the cladding. The highest sensitivity of 27,958.49 nm/RIU, birefringence of 3.9 × <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mn>10</mn><mrow><mo>−</mo><mn>4</mn></mrow></msup></semantics></math></inline-formula>, resolution of 3.70094 × <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mn>10</mn><mrow><mo>−</mo><mn>5</mn></mrow></msup></semantics></math></inline-formula> RIU, and transmittance dip of −34 dB are achieved. The proposed work is a purely numerical simulation with proper optimization. The value of optimization has been referred to with an experimental tolerance value, but at the same time it has been ensured that it is not fabricated and tested. In summary, the explored C-PCF can widely be eligible for RI-based sensing applications for its excellent performance, which makes it a solid candidate for next generation biosensing applications.
ISSN:2079-6374