Stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasible

Lumber artery injuries are anatomically difficult to treat surgically, and coil embolization is a first-line treatment option for them. In some cases, however, there is not enough space for coil embolization, for which stent graft placement can be an alternative therapy. We report a case of traumati...

Full description

Bibliographic Details
Main Authors: Koji Miura, Tatsuhiko Komiya, Susumu Matsushime, Naoki Oka, Keisuke Kamo
Format: Article
Language:English
Published: Elsevier 2023-02-01
Series:Trauma Case Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352644023000225
_version_ 1828038440566915072
author Koji Miura
Tatsuhiko Komiya
Susumu Matsushime
Naoki Oka
Keisuke Kamo
author_facet Koji Miura
Tatsuhiko Komiya
Susumu Matsushime
Naoki Oka
Keisuke Kamo
author_sort Koji Miura
collection DOAJ
description Lumber artery injuries are anatomically difficult to treat surgically, and coil embolization is a first-line treatment option for them. In some cases, however, there is not enough space for coil embolization, for which stent graft placement can be an alternative therapy. We report a case of traumatic lumbar artery injury in which stent graft placement was performed due to lack of space for coil embolization.
first_indexed 2024-04-10T16:27:04Z
format Article
id doaj.art-9c3a9cd0228a400caea1d07c04e1baf0
institution Directory Open Access Journal
issn 2352-6440
language English
last_indexed 2024-04-10T16:27:04Z
publishDate 2023-02-01
publisher Elsevier
record_format Article
series Trauma Case Reports
spelling doaj.art-9c3a9cd0228a400caea1d07c04e1baf02023-02-09T04:14:21ZengElsevierTrauma Case Reports2352-64402023-02-0143100774Stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasibleKoji Miura0Tatsuhiko Komiya1Susumu Matsushime2Naoki Oka3Keisuke Kamo4Corresponding author at: Department of Emergency Medicine, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki 710-8602, Japan.; Department of Emergency Medicine, Kurashiki Central Hospital, Japan; Department of Cardiovascular Surgery, Kurashiki Central Hospital, JapanDepartment of Emergency Medicine, Kurashiki Central Hospital, Japan; Department of Cardiovascular Surgery, Kurashiki Central Hospital, JapanDepartment of Emergency Medicine, Kurashiki Central Hospital, Japan; Department of Cardiovascular Surgery, Kurashiki Central Hospital, JapanDepartment of Emergency Medicine, Kurashiki Central Hospital, Japan; Department of Cardiovascular Surgery, Kurashiki Central Hospital, JapanDepartment of Emergency Medicine, Kurashiki Central Hospital, Japan; Department of Cardiovascular Surgery, Kurashiki Central Hospital, JapanLumber artery injuries are anatomically difficult to treat surgically, and coil embolization is a first-line treatment option for them. In some cases, however, there is not enough space for coil embolization, for which stent graft placement can be an alternative therapy. We report a case of traumatic lumbar artery injury in which stent graft placement was performed due to lack of space for coil embolization.http://www.sciencedirect.com/science/article/pii/S2352644023000225Lumbar artery injuryCoil embolizationEndovascular treatmentStent graftBlunt aortic trauma
spellingShingle Koji Miura
Tatsuhiko Komiya
Susumu Matsushime
Naoki Oka
Keisuke Kamo
Stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasible
Trauma Case Reports
Lumbar artery injury
Coil embolization
Endovascular treatment
Stent graft
Blunt aortic trauma
title Stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasible
title_full Stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasible
title_fullStr Stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasible
title_full_unstemmed Stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasible
title_short Stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasible
title_sort stent graft placement for traumatic lumbar artery injury in which coil embolization is not feasible
topic Lumbar artery injury
Coil embolization
Endovascular treatment
Stent graft
Blunt aortic trauma
url http://www.sciencedirect.com/science/article/pii/S2352644023000225
work_keys_str_mv AT kojimiura stentgraftplacementfortraumaticlumbararteryinjuryinwhichcoilembolizationisnotfeasible
AT tatsuhikokomiya stentgraftplacementfortraumaticlumbararteryinjuryinwhichcoilembolizationisnotfeasible
AT susumumatsushime stentgraftplacementfortraumaticlumbararteryinjuryinwhichcoilembolizationisnotfeasible
AT naokioka stentgraftplacementfortraumaticlumbararteryinjuryinwhichcoilembolizationisnotfeasible
AT keisukekamo stentgraftplacementfortraumaticlumbararteryinjuryinwhichcoilembolizationisnotfeasible