Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction

T2*-weighted gradient echo (GRE) MRI at high field is uniquely sensitive to the magnetic properties of tissue and allows the study of brain and vascular anatomy at high spatial resolution. However, it is also sensitive to B0 field changes induced by head motion and physiological processes such as th...

Full description

Bibliographic Details
Main Authors: Jiaen Liu, Peter van Gelderen, Jacco A. de Zwart, Jeff H. Duyn
Format: Article
Language:English
Published: Elsevier 2020-02-01
Series:NeuroImage
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1053811919309231
_version_ 1818994581496135680
author Jiaen Liu
Peter van Gelderen
Jacco A. de Zwart
Jeff H. Duyn
author_facet Jiaen Liu
Peter van Gelderen
Jacco A. de Zwart
Jeff H. Duyn
author_sort Jiaen Liu
collection DOAJ
description T2*-weighted gradient echo (GRE) MRI at high field is uniquely sensitive to the magnetic properties of tissue and allows the study of brain and vascular anatomy at high spatial resolution. However, it is also sensitive to B0 field changes induced by head motion and physiological processes such as the respiratory cycle. Conventional motion correction techniques do not take these field changes into account, and consequently do not fully recover image quality in T2*-weighted MRI. Here, a novel approach was developed to address this by monitoring the B0 field with a volumetric EPI phase navigator. The navigator was acquired at a shorter echo time than that of the (higher resolution) T2*-weighted GRE imaging data and accelerated with parallel imaging for high temporal resolution. At 4 ​mm isotropic spatial resolution and 0.54 ​s temporal resolution, the accuracy for estimation of rotation and translation was better than 0.2° and 0.1 ​mm, respectively. The 10% and 90% percentiles of B0 measurement error using the navigator were −1.8 and 1.5 Hz  at 7 T, respectively. A fast retrospective reconstruction algorithm correcting for both motion and nonlinear B0 changes was also developed. The navigator and reconstruction algorithm were evaluated in correcting motion-corrupted high-resolution T2*-weighted GRE MRI on healthy human subjects at 7 ​T. Excellent image quality was demonstrated with the proposed correction method.
first_indexed 2024-12-20T21:00:14Z
format Article
id doaj.art-9c560ab6f59e43248f87891ae86887b9
institution Directory Open Access Journal
issn 1095-9572
language English
last_indexed 2024-12-20T21:00:14Z
publishDate 2020-02-01
publisher Elsevier
record_format Article
series NeuroImage
spelling doaj.art-9c560ab6f59e43248f87891ae86887b92022-12-21T19:26:44ZengElsevierNeuroImage1095-95722020-02-01206116332Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correctionJiaen Liu0Peter van Gelderen1Jacco A. de Zwart2Jeff H. Duyn3Corresponding author.; Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr. BLDG. 10, RM. B1D-723, Bethesda, MD, 20892-1065, USAAdvanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr. BLDG. 10, RM. B1D-723, Bethesda, MD, 20892-1065, USAAdvanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr. BLDG. 10, RM. B1D-723, Bethesda, MD, 20892-1065, USAAdvanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr. BLDG. 10, RM. B1D-723, Bethesda, MD, 20892-1065, USAT2*-weighted gradient echo (GRE) MRI at high field is uniquely sensitive to the magnetic properties of tissue and allows the study of brain and vascular anatomy at high spatial resolution. However, it is also sensitive to B0 field changes induced by head motion and physiological processes such as the respiratory cycle. Conventional motion correction techniques do not take these field changes into account, and consequently do not fully recover image quality in T2*-weighted MRI. Here, a novel approach was developed to address this by monitoring the B0 field with a volumetric EPI phase navigator. The navigator was acquired at a shorter echo time than that of the (higher resolution) T2*-weighted GRE imaging data and accelerated with parallel imaging for high temporal resolution. At 4 ​mm isotropic spatial resolution and 0.54 ​s temporal resolution, the accuracy for estimation of rotation and translation was better than 0.2° and 0.1 ​mm, respectively. The 10% and 90% percentiles of B0 measurement error using the navigator were −1.8 and 1.5 Hz  at 7 T, respectively. A fast retrospective reconstruction algorithm correcting for both motion and nonlinear B0 changes was also developed. The navigator and reconstruction algorithm were evaluated in correcting motion-corrupted high-resolution T2*-weighted GRE MRI on healthy human subjects at 7 ​T. Excellent image quality was demonstrated with the proposed correction method.http://www.sciencedirect.com/science/article/pii/S1053811919309231T2*-weighted MRIHigh resolutionMotionB0 fieldEPI phase navigator
spellingShingle Jiaen Liu
Peter van Gelderen
Jacco A. de Zwart
Jeff H. Duyn
Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
NeuroImage
T2*-weighted MRI
High resolution
Motion
B0 field
EPI phase navigator
title Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
title_full Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
title_fullStr Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
title_full_unstemmed Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
title_short Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
title_sort reducing motion sensitivity in 3d high resolution t2 weighted mri by navigator based motion and nonlinear magnetic field correction
topic T2*-weighted MRI
High resolution
Motion
B0 field
EPI phase navigator
url http://www.sciencedirect.com/science/article/pii/S1053811919309231
work_keys_str_mv AT jiaenliu reducingmotionsensitivityin3dhighresolutiont2weightedmribynavigatorbasedmotionandnonlinearmagneticfieldcorrection
AT petervangelderen reducingmotionsensitivityin3dhighresolutiont2weightedmribynavigatorbasedmotionandnonlinearmagneticfieldcorrection
AT jaccoadezwart reducingmotionsensitivityin3dhighresolutiont2weightedmribynavigatorbasedmotionandnonlinearmagneticfieldcorrection
AT jeffhduyn reducingmotionsensitivityin3dhighresolutiont2weightedmribynavigatorbasedmotionandnonlinearmagneticfieldcorrection