Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry

Dosimetric verification of radiation treatment has recently been extended by the introduction of electronic portal imaging devices (EPIDs). Detailed dose response specifications of EPID should be addressed prior to any dosimetric application. The present study evaluates improvements of dosimetric pr...

Full description

Bibliographic Details
Main Authors: Vahideh Nazari, Seied R Mahdavi, Ahmad Mostaar, Hassan Nedaei, Mohammad A Mosleh Shirazi, Alireza Nikoofar, Golbarg Esmailie
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-01-01
Series:Journal of Medical Signals and Sensors
Subjects:
Online Access:http://www.jmss.mui.ac.ir/article.asp?issn=2228-7477;year=2017;volume=7;issue=1;spage=21;epage=25;aulast=Nazari
_version_ 1818407432434483200
author Vahideh Nazari
Seied R Mahdavi
Ahmad Mostaar
Hassan Nedaei
Mohammad A Mosleh Shirazi
Alireza Nikoofar
Golbarg Esmailie
author_facet Vahideh Nazari
Seied R Mahdavi
Ahmad Mostaar
Hassan Nedaei
Mohammad A Mosleh Shirazi
Alireza Nikoofar
Golbarg Esmailie
author_sort Vahideh Nazari
collection DOAJ
description Dosimetric verification of radiation treatment has recently been extended by the introduction of electronic portal imaging devices (EPIDs). Detailed dose response specifications of EPID should be addressed prior to any dosimetric application. The present study evaluates improvements of dosimetric properties of the low elbow camera-based EPID Theraview (Cablon Medical, Leusden, The Netherlands) equipped with a cooled charge coupled device (CCD) for portal dosimetry. The dose response, warm-up behavior, stability over long- and short-term scales (throughout a day) were studied. The field size dependency of the EPID response was also investigated and compared with ion chamber measurements under the same conditions. The EPID response without saturation for doses up to 2 Gy was linear for both beam qualities (6 and 15 MV). There was no evident warm-up characteristic. The detector sensitivity showed excellent stability in short term [standard deviation (SD) 0.38%]. In long-term stability (over a period of approximately 3 months), a negligible linear decline of 0.01% per day was observed. It was concluded that the cooled CCD camera-based EPID could be used for portal dosimetry, after accurate corrections for the field size dependency and sensitivity loss.
first_indexed 2024-12-14T09:27:45Z
format Article
id doaj.art-9cb0496f91104c1ab1d8a9ce0496a705
institution Directory Open Access Journal
issn 2228-7477
language English
last_indexed 2024-12-14T09:27:45Z
publishDate 2017-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Signals and Sensors
spelling doaj.art-9cb0496f91104c1ab1d8a9ce0496a7052022-12-21T23:08:09ZengWolters Kluwer Medknow PublicationsJournal of Medical Signals and Sensors2228-74772017-01-01712125Multi-parametric Improvements in the CCD Camera-based EPID for Portal DosimetryVahideh NazariSeied R MahdaviAhmad MostaarHassan NedaeiMohammad A Mosleh ShiraziAlireza NikoofarGolbarg EsmailieDosimetric verification of radiation treatment has recently been extended by the introduction of electronic portal imaging devices (EPIDs). Detailed dose response specifications of EPID should be addressed prior to any dosimetric application. The present study evaluates improvements of dosimetric properties of the low elbow camera-based EPID Theraview (Cablon Medical, Leusden, The Netherlands) equipped with a cooled charge coupled device (CCD) for portal dosimetry. The dose response, warm-up behavior, stability over long- and short-term scales (throughout a day) were studied. The field size dependency of the EPID response was also investigated and compared with ion chamber measurements under the same conditions. The EPID response without saturation for doses up to 2 Gy was linear for both beam qualities (6 and 15 MV). There was no evident warm-up characteristic. The detector sensitivity showed excellent stability in short term [standard deviation (SD) 0.38%]. In long-term stability (over a period of approximately 3 months), a negligible linear decline of 0.01% per day was observed. It was concluded that the cooled CCD camera-based EPID could be used for portal dosimetry, after accurate corrections for the field size dependency and sensitivity loss.http://www.jmss.mui.ac.ir/article.asp?issn=2228-7477;year=2017;volume=7;issue=1;spage=21;epage=25;aulast=NazariElectronic portal imaging deviceselbowportal dosimetryradiometry
spellingShingle Vahideh Nazari
Seied R Mahdavi
Ahmad Mostaar
Hassan Nedaei
Mohammad A Mosleh Shirazi
Alireza Nikoofar
Golbarg Esmailie
Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry
Journal of Medical Signals and Sensors
Electronic portal imaging devices
elbow
portal dosimetry
radiometry
title Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry
title_full Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry
title_fullStr Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry
title_full_unstemmed Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry
title_short Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry
title_sort multi parametric improvements in the ccd camera based epid for portal dosimetry
topic Electronic portal imaging devices
elbow
portal dosimetry
radiometry
url http://www.jmss.mui.ac.ir/article.asp?issn=2228-7477;year=2017;volume=7;issue=1;spage=21;epage=25;aulast=Nazari
work_keys_str_mv AT vahidehnazari multiparametricimprovementsintheccdcamerabasedepidforportaldosimetry
AT seiedrmahdavi multiparametricimprovementsintheccdcamerabasedepidforportaldosimetry
AT ahmadmostaar multiparametricimprovementsintheccdcamerabasedepidforportaldosimetry
AT hassannedaei multiparametricimprovementsintheccdcamerabasedepidforportaldosimetry
AT mohammadamoslehshirazi multiparametricimprovementsintheccdcamerabasedepidforportaldosimetry
AT alirezanikoofar multiparametricimprovementsintheccdcamerabasedepidforportaldosimetry
AT golbargesmailie multiparametricimprovementsintheccdcamerabasedepidforportaldosimetry