Calibration of Nanopositioning Stages

Accuracy is one of the most important criteria for the performance evaluation of micro- and nanorobots or systems. Nanopositioning stages are used to achieve the high positioning resolution and accuracy for a wide and growing scope of applications. However, their positioning accuracy and repeatabili...

Full description

Bibliographic Details
Main Authors: Ning Tan, Cédric Clévy, Nicolas Chaillet
Format: Article
Language:English
Published: MDPI AG 2015-12-01
Series:Micromachines
Subjects:
Online Access:http://www.mdpi.com/2072-666X/6/12/1461
_version_ 1819168792286068736
author Ning Tan
Cédric Clévy
Nicolas Chaillet
author_facet Ning Tan
Cédric Clévy
Nicolas Chaillet
author_sort Ning Tan
collection DOAJ
description Accuracy is one of the most important criteria for the performance evaluation of micro- and nanorobots or systems. Nanopositioning stages are used to achieve the high positioning resolution and accuracy for a wide and growing scope of applications. However, their positioning accuracy and repeatability are not well known and difficult to guarantee, which induces many drawbacks for many applications. For example, in the mechanical characterisation of biological samples, it is difficult to perform several cycles in a repeatable way so as not to induce negative influences on the study. It also prevents one from controlling accurately a tool with respect to a sample without adding additional sensors for closed loop control. This paper aims at quantifying the positioning repeatability and accuracy based on the ISO 9283:1998 standard, and analyzing factors influencing positioning accuracy onto a case study of 1-DoF (Degree-of-Freedom) nanopositioning stage. The influence of thermal drift is notably quantified. Performances improvement of the nanopositioning stage are then investigated through robot calibration (i.e., open-loop approach). Two models (static and adaptive models) are proposed to compensate for both geometric errors and thermal drift. Validation experiments are conducted over a long period (several days) showing that the accuracy of the stage is improved from typical micrometer range to 400 nm using the static model and even down to 100 nm using the adaptive model. In addition, we extend the 1-DoF calibration to multi-DoF with a case study of a 2-DoF nanopositioning robot. Results demonstrate that the model efficiently improved the 2D accuracy from 1400 nm to 200 nm.
first_indexed 2024-12-22T19:09:14Z
format Article
id doaj.art-9cda9bcf38a446f1937671fa33a208d9
institution Directory Open Access Journal
issn 2072-666X
language English
last_indexed 2024-12-22T19:09:14Z
publishDate 2015-12-01
publisher MDPI AG
record_format Article
series Micromachines
spelling doaj.art-9cda9bcf38a446f1937671fa33a208d92022-12-21T18:15:42ZengMDPI AGMicromachines2072-666X2015-12-016121856187510.3390/mi6121461mi6121461Calibration of Nanopositioning StagesNing Tan0Cédric Clévy1Nicolas Chaillet2FEMTO-ST Institute, UMR CNRS 6174 - UFC / ENSMM / UTBM, Université de Franche-Comté, 25000 Besançon, FranceFEMTO-ST Institute, UMR CNRS 6174 - UFC / ENSMM / UTBM, Université de Franche-Comté, 25000 Besançon, FranceFEMTO-ST Institute, UMR CNRS 6174 - UFC / ENSMM / UTBM, Université de Franche-Comté, 25000 Besançon, FranceAccuracy is one of the most important criteria for the performance evaluation of micro- and nanorobots or systems. Nanopositioning stages are used to achieve the high positioning resolution and accuracy for a wide and growing scope of applications. However, their positioning accuracy and repeatability are not well known and difficult to guarantee, which induces many drawbacks for many applications. For example, in the mechanical characterisation of biological samples, it is difficult to perform several cycles in a repeatable way so as not to induce negative influences on the study. It also prevents one from controlling accurately a tool with respect to a sample without adding additional sensors for closed loop control. This paper aims at quantifying the positioning repeatability and accuracy based on the ISO 9283:1998 standard, and analyzing factors influencing positioning accuracy onto a case study of 1-DoF (Degree-of-Freedom) nanopositioning stage. The influence of thermal drift is notably quantified. Performances improvement of the nanopositioning stage are then investigated through robot calibration (i.e., open-loop approach). Two models (static and adaptive models) are proposed to compensate for both geometric errors and thermal drift. Validation experiments are conducted over a long period (several days) showing that the accuracy of the stage is improved from typical micrometer range to 400 nm using the static model and even down to 100 nm using the adaptive model. In addition, we extend the 1-DoF calibration to multi-DoF with a case study of a 2-DoF nanopositioning robot. Results demonstrate that the model efficiently improved the 2D accuracy from 1400 nm to 200 nm.http://www.mdpi.com/2072-666X/6/12/1461nanopositioning stagescalibrationgeometric errorthermal compensationopen loopaccuracyrepeatability
spellingShingle Ning Tan
Cédric Clévy
Nicolas Chaillet
Calibration of Nanopositioning Stages
Micromachines
nanopositioning stages
calibration
geometric error
thermal compensation
open loop
accuracy
repeatability
title Calibration of Nanopositioning Stages
title_full Calibration of Nanopositioning Stages
title_fullStr Calibration of Nanopositioning Stages
title_full_unstemmed Calibration of Nanopositioning Stages
title_short Calibration of Nanopositioning Stages
title_sort calibration of nanopositioning stages
topic nanopositioning stages
calibration
geometric error
thermal compensation
open loop
accuracy
repeatability
url http://www.mdpi.com/2072-666X/6/12/1461
work_keys_str_mv AT ningtan calibrationofnanopositioningstages
AT cedricclevy calibrationofnanopositioningstages
AT nicolaschaillet calibrationofnanopositioningstages