Design of 6 switched 3-level inverter with RL load

<span>In this study, an alternative topology to multilevel inverter topologies is given. 6 IGBT seminconductor switches are used in this topology and coupled inductors are used in the output stage of the inverter. Using coupled inductors voltages, the 6 switched 3-level inverter has been obtai...

Full description

Bibliographic Details
Main Authors: Ali Saygın, Alper Kerem
Format: Article
Language:English
Published: Pamukkale University 2016-10-01
Series:Pamukkale University Journal of Engineering Sciences
Online Access:http://dergipark.ulakbim.gov.tr/pajes/article/view/5000204965
Description
Summary:<span>In this study, an alternative topology to multilevel inverter topologies is given. 6 IGBT seminconductor switches are used in this topology and coupled inductors are used in the output stage of the inverter. Using coupled inductors voltages, the 6 switched 3-level inverter has been obtained. In the simulation study, Proportional Integral (PI) controller has been used. By using the data taken from controller, the required switching signals have been produced for a 6 switched 3-level inverter. These signals have been taken by using space vector pulse width modulation technique. Using Computer Aided Design (CAD) analysis a RL load that have 10 Ω and 0.2 H values is simulated and inverter performance has been investigated.</span>
ISSN:1300-7009