Detection of Interphase Fault Zone in Overhead Power Distribution Networks

Parametric methods have been recommended on the basis of current and voltage value recording in normal and emergency modes at a sub-transmission substation in order to detect two- and three-phase short circuits in overhead power distribution networks. The paper proposes to detect an inspection zone...

Full description

Bibliographic Details
Main Author: E. V. Kalentionok
Format: Article
Language:Russian
Published: Belarusian National Technical University 2013-08-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Online Access:https://energy.bntu.by/jour/article/view/135
_version_ 1797879826190696448
author E. V. Kalentionok
author_facet E. V. Kalentionok
author_sort E. V. Kalentionok
collection DOAJ
description Parametric methods have been recommended on the basis of current and voltage value recording in normal and emergency modes at a sub-transmission substation in order to detect two- and three-phase short circuits in overhead power distribution networks. The paper proposes to detect an inspection zone in order to locate an interphase fault with the help of analytical calculation of distance up to the fault point using 3–4 expressions on the basis of data obtained as a result of multiple metering pertaining to emergency mode parameters  with their subsequent statistical processing.
first_indexed 2024-04-10T02:54:58Z
format Article
id doaj.art-9d9f16c2a0dc491da55622a6335b537f
institution Directory Open Access Journal
issn 1029-7448
2414-0341
language Russian
last_indexed 2024-04-10T02:54:58Z
publishDate 2013-08-01
publisher Belarusian National Technical University
record_format Article
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
spelling doaj.art-9d9f16c2a0dc491da55622a6335b537f2023-03-13T07:41:48ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412013-08-0104129Detection of Interphase Fault Zone in Overhead Power Distribution NetworksE. V. Kalentionok0Белорусский национальный технический университетParametric methods have been recommended on the basis of current and voltage value recording in normal and emergency modes at a sub-transmission substation in order to detect two- and three-phase short circuits in overhead power distribution networks. The paper proposes to detect an inspection zone in order to locate an interphase fault with the help of analytical calculation of distance up to the fault point using 3–4 expressions on the basis of data obtained as a result of multiple metering pertaining to emergency mode parameters  with their subsequent statistical processing.https://energy.bntu.by/jour/article/view/135
spellingShingle E. V. Kalentionok
Detection of Interphase Fault Zone in Overhead Power Distribution Networks
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
title Detection of Interphase Fault Zone in Overhead Power Distribution Networks
title_full Detection of Interphase Fault Zone in Overhead Power Distribution Networks
title_fullStr Detection of Interphase Fault Zone in Overhead Power Distribution Networks
title_full_unstemmed Detection of Interphase Fault Zone in Overhead Power Distribution Networks
title_short Detection of Interphase Fault Zone in Overhead Power Distribution Networks
title_sort detection of interphase fault zone in overhead power distribution networks
url https://energy.bntu.by/jour/article/view/135
work_keys_str_mv AT evkalentionok detectionofinterphasefaultzoneinoverheadpowerdistributionnetworks