Differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implants

In the practice of pediatric traumatologists there are a number of complex problems in the treatment of fractures of the distal humerus, which require a differentiated approach: atraumatic anatomical reposition with minimal damage to active growth zones, minimal damage to articular cartilage during...

Full description

Bibliographic Details
Main Author: M. Lyutkevych
Format: Article
Language:English
Published: Group of Companies Med Expert, LLC, Kyev, Ukraine 2022-03-01
Series:Хірургія дитячого віку
Subjects:
Online Access:http://psu.med-expert.com.ua/article/view/254993
_version_ 1828107905315897344
author M. Lyutkevych
author_facet M. Lyutkevych
author_sort M. Lyutkevych
collection DOAJ
description In the practice of pediatric traumatologists there are a number of complex problems in the treatment of fractures of the distal humerus, which require a differentiated approach: atraumatic anatomical reposition with minimal damage to active growth zones, minimal damage to articular cartilage during surgery, stable fixation and early rehabilitation. At present, the generally accepted methods of osteosynthesis (fixation with K - wires, metal screws, etc.) do not fully meet the requirements of modern pediatric traumatology. One of the newest methods of fixation in the treatment of fractures of this localization, which have significant advantages is the use of bioabsorbable implants (BAI). Purpose - to present a differential approach to the treatment of distal fractures of the humerus in children based on the use of bioabsorbable implants. Materials and methods. During the period from 2015 to 2021, 15 children aged 5 to 17 were treated at the Chernihiv Regional Children’s Hospital. Distribution by type of pathology: epiphyseal fracture of the humeral condyle head - 5, osteoepiphyseolysis of the lateral humerus condyle - 2, fracture of the medial epicondyle of the humerus - 8 cases. Damage to nerve and vascular structures was never diagnosed in this group of patients. At the preoperative stage, radiography of the elbow joint in standard projections for such injuries was used to diagnose the above injuries. In the course of surgery, bioabsorbable cannulated screws and Bioretec pins were used to fix the repositioned fragments. Results. In the process of surgery, standard approaches and repositioning techniques were used, according to the anatomical features of each fracture. The differentiated approach was to use cannulated screws in the case of osteosynthesis of extra-articular fractures (osteoepiphyseolysis of the medial epicondyle of the humerus) in older children (12 to 17 years), which allowed to create dosed compression of fragments and bioabsorbable perfect anatomical reposition. In 1 case there was a combined osteosynthesis: fixation of the metaphyseal fragment with a K - wires and synthesis of the intra-articular epiphyseal fragment with a bioabsorbent pin. Advantages of BAI: minimal damage to articular cartilage, preservation of congruence and anatomical shape of the articular surface at the site of implant placement (Pin), stable fixation and interfragmentary compression (autocompression property), intraoperatively received full range of motion in the joint. All patients received full consolidation in time according to the age of the injured child. The range of motion and function of the limb is completely restored. The children did not need repeated surgery. Conclusions. 1. The advantages of using bioabsorbable implants in cases of treatment of fractures of the distal humerus in children are demonstrated. 2. The use of BAI allows to minimize damage to the growth zones and joint surface during osteosynthesis, provides stable fixation and interfragmentary compression, creates conditions for optimal fracture fusion and further rehabilitation. 3. Due to the properties of bioabsorption there is no need to remove the implant, ie re-trauma to the structures of the elbow joint of the growing organism, no need for re-hospitalization, anesthesia and surgery, re-rehabilitation, reduces the likelihood of psychological trauma in children. 4. As a result, all of the above improves the anatomical and functional results of treatment of these injuries, saves financial costs of both the medical institution and the state, and reduces the stress on family budgets. The research was carried out in accordance with the principles of the Helsinki declaration. The informed consent of the patient was obtained for conducting the studies. No conflict of interests was declared by the authors.
first_indexed 2024-04-11T10:38:04Z
format Article
id doaj.art-9da5aed66aab4656b84ff9254c17c1d8
institution Directory Open Access Journal
issn 2304-0041
2521-1358
language English
last_indexed 2024-04-11T10:38:04Z
publishDate 2022-03-01
publisher Group of Companies Med Expert, LLC, Kyev, Ukraine
record_format Article
series Хірургія дитячого віку
spelling doaj.art-9da5aed66aab4656b84ff9254c17c1d82022-12-22T04:29:15ZengGroup of Companies Med Expert, LLC, Kyev, UkraineХірургія дитячого віку2304-00412521-13582022-03-011(74)979810.15574/PS.2022.74.97292903Differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implantsM. Lyutkevych0Chernihiv Regional Children’s Hospital, UkraineIn the practice of pediatric traumatologists there are a number of complex problems in the treatment of fractures of the distal humerus, which require a differentiated approach: atraumatic anatomical reposition with minimal damage to active growth zones, minimal damage to articular cartilage during surgery, stable fixation and early rehabilitation. At present, the generally accepted methods of osteosynthesis (fixation with K - wires, metal screws, etc.) do not fully meet the requirements of modern pediatric traumatology. One of the newest methods of fixation in the treatment of fractures of this localization, which have significant advantages is the use of bioabsorbable implants (BAI). Purpose - to present a differential approach to the treatment of distal fractures of the humerus in children based on the use of bioabsorbable implants. Materials and methods. During the period from 2015 to 2021, 15 children aged 5 to 17 were treated at the Chernihiv Regional Children’s Hospital. Distribution by type of pathology: epiphyseal fracture of the humeral condyle head - 5, osteoepiphyseolysis of the lateral humerus condyle - 2, fracture of the medial epicondyle of the humerus - 8 cases. Damage to nerve and vascular structures was never diagnosed in this group of patients. At the preoperative stage, radiography of the elbow joint in standard projections for such injuries was used to diagnose the above injuries. In the course of surgery, bioabsorbable cannulated screws and Bioretec pins were used to fix the repositioned fragments. Results. In the process of surgery, standard approaches and repositioning techniques were used, according to the anatomical features of each fracture. The differentiated approach was to use cannulated screws in the case of osteosynthesis of extra-articular fractures (osteoepiphyseolysis of the medial epicondyle of the humerus) in older children (12 to 17 years), which allowed to create dosed compression of fragments and bioabsorbable perfect anatomical reposition. In 1 case there was a combined osteosynthesis: fixation of the metaphyseal fragment with a K - wires and synthesis of the intra-articular epiphyseal fragment with a bioabsorbent pin. Advantages of BAI: minimal damage to articular cartilage, preservation of congruence and anatomical shape of the articular surface at the site of implant placement (Pin), stable fixation and interfragmentary compression (autocompression property), intraoperatively received full range of motion in the joint. All patients received full consolidation in time according to the age of the injured child. The range of motion and function of the limb is completely restored. The children did not need repeated surgery. Conclusions. 1. The advantages of using bioabsorbable implants in cases of treatment of fractures of the distal humerus in children are demonstrated. 2. The use of BAI allows to minimize damage to the growth zones and joint surface during osteosynthesis, provides stable fixation and interfragmentary compression, creates conditions for optimal fracture fusion and further rehabilitation. 3. Due to the properties of bioabsorption there is no need to remove the implant, ie re-trauma to the structures of the elbow joint of the growing organism, no need for re-hospitalization, anesthesia and surgery, re-rehabilitation, reduces the likelihood of psychological trauma in children. 4. As a result, all of the above improves the anatomical and functional results of treatment of these injuries, saves financial costs of both the medical institution and the state, and reduces the stress on family budgets. The research was carried out in accordance with the principles of the Helsinki declaration. The informed consent of the patient was obtained for conducting the studies. No conflict of interests was declared by the authors.http://psu.med-expert.com.ua/article/view/254993childrenbioabsorbable implantsfractures of the distal humerustrauma in childrengrowth zonesosteosynthesis
spellingShingle M. Lyutkevych
Differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implants
Хірургія дитячого віку
children
bioabsorbable implants
fractures of the distal humerus
trauma in children
growth zones
osteosynthesis
title Differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implants
title_full Differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implants
title_fullStr Differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implants
title_full_unstemmed Differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implants
title_short Differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implants
title_sort differentiated approach in the treatment of fractures of the distal humerus in children based on the use of bioabsorbable implants
topic children
bioabsorbable implants
fractures of the distal humerus
trauma in children
growth zones
osteosynthesis
url http://psu.med-expert.com.ua/article/view/254993
work_keys_str_mv AT mlyutkevych differentiatedapproachinthetreatmentoffracturesofthedistalhumerusinchildrenbasedontheuseofbioabsorbableimplants