TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS

Objective: To develop titanium clamps with a biologically modified surface, and estimate its biocompatibility and probability of its application in clinical practice for patients with mandibular fractures. Methods: The experimental research was conducted on laboratory animals, as well as in treat...

Full description

Bibliographic Details
Main Authors: A.I. YARYOMENKO, K.I. STARKOVSKIY, A.L. RUBEZHOV
Format: Article
Language:English
Published: Avicenna Tajik State Medical University 2021-03-01
Series:Паёми Сино
Subjects:
Online Access:https://doi.org/10.25005/2074-0581-2021-23-1-53-59
_version_ 1797803276020744192
author A.I. YARYOMENKO
K.I. STARKOVSKIY
A.L. RUBEZHOV
author_facet A.I. YARYOMENKO
K.I. STARKOVSKIY
A.L. RUBEZHOV
author_sort A.I. YARYOMENKO
collection DOAJ
description Objective: To develop titanium clamps with a biologically modified surface, and estimate its biocompatibility and probability of its application in clinical practice for patients with mandibular fractures. Methods: The experimental research was conducted on laboratory animals, as well as in treatment of 14 patients with mandibular fractures, to study biocompatibility of the designed titanium clamps. All the patients underwent osteosynthesis of the lower jaw with the application of the designed titanium clamps with a biologically modified surface. Results: It has been revealed that the all-cast titanium clamps with the laser-processed surface most optimally meet the requirements imposed to the materials applied to mandible metalosteosynthesis. Conclusion: The application of the designed titanium clamps with a biologically modified surface allows accurately fix and hold lower jaw fractures in the exact physiological position until final consolidation.
first_indexed 2024-03-13T05:19:24Z
format Article
id doaj.art-9db10a14e6db49429c1aad4e80676c74
institution Directory Open Access Journal
issn 2074-0581
2959-6327
language English
last_indexed 2024-03-13T05:19:24Z
publishDate 2021-03-01
publisher Avicenna Tajik State Medical University
record_format Article
series Паёми Сино
spelling doaj.art-9db10a14e6db49429c1aad4e80676c742023-06-15T17:09:50ZengAvicenna Tajik State Medical UniversityПаёми Сино2074-05812959-63272021-03-01231535910.25005/2074-0581-2021-23-1-53-59TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESISA.I. YARYOMENKO0K.I. STARKOVSKIY1A.L. RUBEZHOV2Department of Dentistry and Maxillofacial Surgery, Pavlov First Saint Petersburg State Medical University, Saint Petersburg, Russian FederationDepartment of Dentistry and Maxillofacial Surgery, Pavlov First Saint Petersburg State Medical University, Saint Petersburg, Russian Federation. Dental Clinic № 9, Saint Petersburg, Russian FederationDental Clinic № 9, Saint Petersburg, Russian Federation. Department of Dentistry of General Practice, Mechnikov North-West State Medical University, Saint Petersburg, Russian FederationObjective: To develop titanium clamps with a biologically modified surface, and estimate its biocompatibility and probability of its application in clinical practice for patients with mandibular fractures. Methods: The experimental research was conducted on laboratory animals, as well as in treatment of 14 patients with mandibular fractures, to study biocompatibility of the designed titanium clamps. All the patients underwent osteosynthesis of the lower jaw with the application of the designed titanium clamps with a biologically modified surface. Results: It has been revealed that the all-cast titanium clamps with the laser-processed surface most optimally meet the requirements imposed to the materials applied to mandible metalosteosynthesis. Conclusion: The application of the designed titanium clamps with a biologically modified surface allows accurately fix and hold lower jaw fractures in the exact physiological position until final consolidation.https://doi.org/10.25005/2074-0581-2021-23-1-53-59biocompatibilityminiplatemandibleosteointegrationosteosynthesispolymeric coveringtitanium clamp.
spellingShingle A.I. YARYOMENKO
K.I. STARKOVSKIY
A.L. RUBEZHOV
TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS
Паёми Сино
biocompatibility
miniplate
mandible
osteointegration
osteosynthesis
polymeric covering
titanium clamp.
title TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS
title_full TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS
title_fullStr TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS
title_full_unstemmed TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS
title_short TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS
title_sort titanium clamps with modified surface and their application for mandible osteosynthesis
topic biocompatibility
miniplate
mandible
osteointegration
osteosynthesis
polymeric covering
titanium clamp.
url https://doi.org/10.25005/2074-0581-2021-23-1-53-59
work_keys_str_mv AT aiyaryomenko titaniumclampswithmodifiedsurfaceandtheirapplicationformandibleosteosynthesis
AT kistarkovskiy titaniumclampswithmodifiedsurfaceandtheirapplicationformandibleosteosynthesis
AT alrubezhov titaniumclampswithmodifiedsurfaceandtheirapplicationformandibleosteosynthesis