TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS
Objective: To develop titanium clamps with a biologically modified surface, and estimate its biocompatibility and probability of its application in clinical practice for patients with mandibular fractures. Methods: The experimental research was conducted on laboratory animals, as well as in treat...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Avicenna Tajik State Medical University
2021-03-01
|
Series: | Паёми Сино |
Subjects: | |
Online Access: | https://doi.org/10.25005/2074-0581-2021-23-1-53-59 |
_version_ | 1797803276020744192 |
---|---|
author | A.I. YARYOMENKO K.I. STARKOVSKIY A.L. RUBEZHOV |
author_facet | A.I. YARYOMENKO K.I. STARKOVSKIY A.L. RUBEZHOV |
author_sort | A.I. YARYOMENKO |
collection | DOAJ |
description | Objective: To develop titanium clamps with a biologically modified surface, and estimate its biocompatibility and probability of its application in clinical practice for patients with mandibular fractures.
Methods: The experimental research was conducted on laboratory animals, as well as in treatment of 14 patients with mandibular fractures, to study biocompatibility of the designed titanium clamps. All the patients underwent osteosynthesis of the lower jaw with the application of the designed titanium clamps with a biologically modified surface.
Results: It has been revealed that the all-cast titanium clamps with the laser-processed surface most optimally meet the requirements imposed to the materials applied to mandible metalosteosynthesis.
Conclusion: The application of the designed titanium clamps with a biologically modified surface allows accurately fix and hold lower jaw fractures in the exact physiological position until final consolidation. |
first_indexed | 2024-03-13T05:19:24Z |
format | Article |
id | doaj.art-9db10a14e6db49429c1aad4e80676c74 |
institution | Directory Open Access Journal |
issn | 2074-0581 2959-6327 |
language | English |
last_indexed | 2024-03-13T05:19:24Z |
publishDate | 2021-03-01 |
publisher | Avicenna Tajik State Medical University |
record_format | Article |
series | Паёми Сино |
spelling | doaj.art-9db10a14e6db49429c1aad4e80676c742023-06-15T17:09:50ZengAvicenna Tajik State Medical UniversityПаёми Сино2074-05812959-63272021-03-01231535910.25005/2074-0581-2021-23-1-53-59TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESISA.I. YARYOMENKO0K.I. STARKOVSKIY1A.L. RUBEZHOV2Department of Dentistry and Maxillofacial Surgery, Pavlov First Saint Petersburg State Medical University, Saint Petersburg, Russian FederationDepartment of Dentistry and Maxillofacial Surgery, Pavlov First Saint Petersburg State Medical University, Saint Petersburg, Russian Federation. Dental Clinic № 9, Saint Petersburg, Russian FederationDental Clinic № 9, Saint Petersburg, Russian Federation. Department of Dentistry of General Practice, Mechnikov North-West State Medical University, Saint Petersburg, Russian FederationObjective: To develop titanium clamps with a biologically modified surface, and estimate its biocompatibility and probability of its application in clinical practice for patients with mandibular fractures. Methods: The experimental research was conducted on laboratory animals, as well as in treatment of 14 patients with mandibular fractures, to study biocompatibility of the designed titanium clamps. All the patients underwent osteosynthesis of the lower jaw with the application of the designed titanium clamps with a biologically modified surface. Results: It has been revealed that the all-cast titanium clamps with the laser-processed surface most optimally meet the requirements imposed to the materials applied to mandible metalosteosynthesis. Conclusion: The application of the designed titanium clamps with a biologically modified surface allows accurately fix and hold lower jaw fractures in the exact physiological position until final consolidation.https://doi.org/10.25005/2074-0581-2021-23-1-53-59biocompatibilityminiplatemandibleosteointegrationosteosynthesispolymeric coveringtitanium clamp. |
spellingShingle | A.I. YARYOMENKO K.I. STARKOVSKIY A.L. RUBEZHOV TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS Паёми Сино biocompatibility miniplate mandible osteointegration osteosynthesis polymeric covering titanium clamp. |
title | TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS |
title_full | TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS |
title_fullStr | TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS |
title_full_unstemmed | TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS |
title_short | TITANIUM CLAMPS WITH MODIFIED SURFACE AND THEIR APPLICATION FOR MANDIBLE OSTEOSYNTHESIS |
title_sort | titanium clamps with modified surface and their application for mandible osteosynthesis |
topic | biocompatibility miniplate mandible osteointegration osteosynthesis polymeric covering titanium clamp. |
url | https://doi.org/10.25005/2074-0581-2021-23-1-53-59 |
work_keys_str_mv | AT aiyaryomenko titaniumclampswithmodifiedsurfaceandtheirapplicationformandibleosteosynthesis AT kistarkovskiy titaniumclampswithmodifiedsurfaceandtheirapplicationformandibleosteosynthesis AT alrubezhov titaniumclampswithmodifiedsurfaceandtheirapplicationformandibleosteosynthesis |