Replication of Radial Pulses Using Magneto-Rheological Fluids

The radial pulse is a critical health marker with expanding applications in wearable technology. To improve these applications, developing a pulse generator that consistently produces realistic pulses is crucial for validation and training. The goal of this study was to design and test a cost-effect...

Full description

Bibliographic Details
Main Authors: Miranda Eaton, Jeong-Hoi Koo, Tae-Heon Yang, Young-Min Kim
Format: Article
Language:English
Published: MDPI AG 2024-08-01
Series:Micromachines
Subjects:
Online Access:https://www.mdpi.com/2072-666X/15/8/1010
_version_ 1827133827936419840
author Miranda Eaton
Jeong-Hoi Koo
Tae-Heon Yang
Young-Min Kim
author_facet Miranda Eaton
Jeong-Hoi Koo
Tae-Heon Yang
Young-Min Kim
author_sort Miranda Eaton
collection DOAJ
description The radial pulse is a critical health marker with expanding applications in wearable technology. To improve these applications, developing a pulse generator that consistently produces realistic pulses is crucial for validation and training. The goal of this study was to design and test a cost-effective pulse simulator that can accurately replicate a wide range of age-dependent radial pulses with simplicity and precision. To this end, this study incorporated a magneto-rheological (MR) fluid device into a cam-based pulse simulator. The MR device, as a key component, enables pulse shaping without the need for additional cams, substantially reducing the cost and complexity of control compared with existing pulse simulators. To evaluate the performance of the MR pulse simulator, the root-mean-square (RMS) error criterion (less than 5%) was used to compare the experimentally obtained pulse waveform with the in vivo pulse waveform for specific age groups. After demonstrating that the MR simulator could produce three representative in vivo pulses, a parametric study was conducted to show the feasibility of the slope-based pulse-shaping method for the MR pulse simulator to continuously generate a range of age-related pulses.
first_indexed 2025-03-20T17:10:04Z
format Article
id doaj.art-9e51a4f6d1514f8e9a07b7fef5d1ca49
institution Directory Open Access Journal
issn 2072-666X
language English
last_indexed 2025-03-20T17:10:04Z
publishDate 2024-08-01
publisher MDPI AG
record_format Article
series Micromachines
spelling doaj.art-9e51a4f6d1514f8e9a07b7fef5d1ca492024-08-28T14:31:35ZengMDPI AGMicromachines2072-666X2024-08-01158101010.3390/mi15081010Replication of Radial Pulses Using Magneto-Rheological FluidsMiranda Eaton0Jeong-Hoi Koo1Tae-Heon Yang2Young-Min Kim3Department of Mechanical and Manufacturing Engineering, Miami University, Oxford, OH 45056, USADepartment of Mechanical and Manufacturing Engineering, Miami University, Oxford, OH 45056, USADepartment of Mechanical Engineering, Konkuk University, Seoul 05029, Republic of KoreaDigital Health Research Division, Korea Institute of Oriental Medicine, 1672 Yuseong-daero, Yuseong-gu, Daejeon 34054, Republic of KoreaThe radial pulse is a critical health marker with expanding applications in wearable technology. To improve these applications, developing a pulse generator that consistently produces realistic pulses is crucial for validation and training. The goal of this study was to design and test a cost-effective pulse simulator that can accurately replicate a wide range of age-dependent radial pulses with simplicity and precision. To this end, this study incorporated a magneto-rheological (MR) fluid device into a cam-based pulse simulator. The MR device, as a key component, enables pulse shaping without the need for additional cams, substantially reducing the cost and complexity of control compared with existing pulse simulators. To evaluate the performance of the MR pulse simulator, the root-mean-square (RMS) error criterion (less than 5%) was used to compare the experimentally obtained pulse waveform with the in vivo pulse waveform for specific age groups. After demonstrating that the MR simulator could produce three representative in vivo pulses, a parametric study was conducted to show the feasibility of the slope-based pulse-shaping method for the MR pulse simulator to continuously generate a range of age-related pulses.https://www.mdpi.com/2072-666X/15/8/1010magneto-rheological fluidsradial pulsespulse waveformspulse simulation
spellingShingle Miranda Eaton
Jeong-Hoi Koo
Tae-Heon Yang
Young-Min Kim
Replication of Radial Pulses Using Magneto-Rheological Fluids
Micromachines
magneto-rheological fluids
radial pulses
pulse waveforms
pulse simulation
title Replication of Radial Pulses Using Magneto-Rheological Fluids
title_full Replication of Radial Pulses Using Magneto-Rheological Fluids
title_fullStr Replication of Radial Pulses Using Magneto-Rheological Fluids
title_full_unstemmed Replication of Radial Pulses Using Magneto-Rheological Fluids
title_short Replication of Radial Pulses Using Magneto-Rheological Fluids
title_sort replication of radial pulses using magneto rheological fluids
topic magneto-rheological fluids
radial pulses
pulse waveforms
pulse simulation
url https://www.mdpi.com/2072-666X/15/8/1010
work_keys_str_mv AT mirandaeaton replicationofradialpulsesusingmagnetorheologicalfluids
AT jeonghoikoo replicationofradialpulsesusingmagnetorheologicalfluids
AT taeheonyang replicationofradialpulsesusingmagnetorheologicalfluids
AT youngminkim replicationofradialpulsesusingmagnetorheologicalfluids