Replication of Radial Pulses Using Magneto-Rheological Fluids
The radial pulse is a critical health marker with expanding applications in wearable technology. To improve these applications, developing a pulse generator that consistently produces realistic pulses is crucial for validation and training. The goal of this study was to design and test a cost-effect...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2024-08-01
|
Series: | Micromachines |
Subjects: | |
Online Access: | https://www.mdpi.com/2072-666X/15/8/1010 |
_version_ | 1827133827936419840 |
---|---|
author | Miranda Eaton Jeong-Hoi Koo Tae-Heon Yang Young-Min Kim |
author_facet | Miranda Eaton Jeong-Hoi Koo Tae-Heon Yang Young-Min Kim |
author_sort | Miranda Eaton |
collection | DOAJ |
description | The radial pulse is a critical health marker with expanding applications in wearable technology. To improve these applications, developing a pulse generator that consistently produces realistic pulses is crucial for validation and training. The goal of this study was to design and test a cost-effective pulse simulator that can accurately replicate a wide range of age-dependent radial pulses with simplicity and precision. To this end, this study incorporated a magneto-rheological (MR) fluid device into a cam-based pulse simulator. The MR device, as a key component, enables pulse shaping without the need for additional cams, substantially reducing the cost and complexity of control compared with existing pulse simulators. To evaluate the performance of the MR pulse simulator, the root-mean-square (RMS) error criterion (less than 5%) was used to compare the experimentally obtained pulse waveform with the in vivo pulse waveform for specific age groups. After demonstrating that the MR simulator could produce three representative in vivo pulses, a parametric study was conducted to show the feasibility of the slope-based pulse-shaping method for the MR pulse simulator to continuously generate a range of age-related pulses. |
first_indexed | 2025-03-20T17:10:04Z |
format | Article |
id | doaj.art-9e51a4f6d1514f8e9a07b7fef5d1ca49 |
institution | Directory Open Access Journal |
issn | 2072-666X |
language | English |
last_indexed | 2025-03-20T17:10:04Z |
publishDate | 2024-08-01 |
publisher | MDPI AG |
record_format | Article |
series | Micromachines |
spelling | doaj.art-9e51a4f6d1514f8e9a07b7fef5d1ca492024-08-28T14:31:35ZengMDPI AGMicromachines2072-666X2024-08-01158101010.3390/mi15081010Replication of Radial Pulses Using Magneto-Rheological FluidsMiranda Eaton0Jeong-Hoi Koo1Tae-Heon Yang2Young-Min Kim3Department of Mechanical and Manufacturing Engineering, Miami University, Oxford, OH 45056, USADepartment of Mechanical and Manufacturing Engineering, Miami University, Oxford, OH 45056, USADepartment of Mechanical Engineering, Konkuk University, Seoul 05029, Republic of KoreaDigital Health Research Division, Korea Institute of Oriental Medicine, 1672 Yuseong-daero, Yuseong-gu, Daejeon 34054, Republic of KoreaThe radial pulse is a critical health marker with expanding applications in wearable technology. To improve these applications, developing a pulse generator that consistently produces realistic pulses is crucial for validation and training. The goal of this study was to design and test a cost-effective pulse simulator that can accurately replicate a wide range of age-dependent radial pulses with simplicity and precision. To this end, this study incorporated a magneto-rheological (MR) fluid device into a cam-based pulse simulator. The MR device, as a key component, enables pulse shaping without the need for additional cams, substantially reducing the cost and complexity of control compared with existing pulse simulators. To evaluate the performance of the MR pulse simulator, the root-mean-square (RMS) error criterion (less than 5%) was used to compare the experimentally obtained pulse waveform with the in vivo pulse waveform for specific age groups. After demonstrating that the MR simulator could produce three representative in vivo pulses, a parametric study was conducted to show the feasibility of the slope-based pulse-shaping method for the MR pulse simulator to continuously generate a range of age-related pulses.https://www.mdpi.com/2072-666X/15/8/1010magneto-rheological fluidsradial pulsespulse waveformspulse simulation |
spellingShingle | Miranda Eaton Jeong-Hoi Koo Tae-Heon Yang Young-Min Kim Replication of Radial Pulses Using Magneto-Rheological Fluids Micromachines magneto-rheological fluids radial pulses pulse waveforms pulse simulation |
title | Replication of Radial Pulses Using Magneto-Rheological Fluids |
title_full | Replication of Radial Pulses Using Magneto-Rheological Fluids |
title_fullStr | Replication of Radial Pulses Using Magneto-Rheological Fluids |
title_full_unstemmed | Replication of Radial Pulses Using Magneto-Rheological Fluids |
title_short | Replication of Radial Pulses Using Magneto-Rheological Fluids |
title_sort | replication of radial pulses using magneto rheological fluids |
topic | magneto-rheological fluids radial pulses pulse waveforms pulse simulation |
url | https://www.mdpi.com/2072-666X/15/8/1010 |
work_keys_str_mv | AT mirandaeaton replicationofradialpulsesusingmagnetorheologicalfluids AT jeonghoikoo replicationofradialpulsesusingmagnetorheologicalfluids AT taeheonyang replicationofradialpulsesusingmagnetorheologicalfluids AT youngminkim replicationofradialpulsesusingmagnetorheologicalfluids |