Depth-dose distribution in potatoes with low-energy X-rays

Irradiation is known as a handful measure to inhibit potato sprouting, kill harmful bacteria, and increase preservation. The absorbed dose is one of the essential characteristics of the irradiation process. In this study, the depth-dose distributions in potatoes and polymethyl methacrylate were inv...

Full description

Bibliographic Details
Main Authors: Thi Nguyet Ha Nguyen, Kume Tamikazu, An Son Nguyen, Thi Minh Sang Nguyen, Thi Ngoc Ha Pham, Danh Hung Nguyen, Van Hai Cao, Quang Kien Nguyen, Huu Duc Nguyen, Thi Le Do
Format: Article
Language:English
Published: HUJOS 2022-06-01
Series:Tạp chí Khoa học Đại học Huế: Khoa học Tự nhiên
Subjects:
Online Access:https://jos.hueuni.edu.vn/index.php/hujos-ns/article/view/6514
_version_ 1797895420207169536
author Thi Nguyet Ha Nguyen
Kume Tamikazu
An Son Nguyen
Thi Minh Sang Nguyen
Thi Ngoc Ha Pham
Danh Hung Nguyen
Van Hai Cao
Quang Kien Nguyen
Huu Duc Nguyen
Thi Le Do
author_facet Thi Nguyet Ha Nguyen
Kume Tamikazu
An Son Nguyen
Thi Minh Sang Nguyen
Thi Ngoc Ha Pham
Danh Hung Nguyen
Van Hai Cao
Quang Kien Nguyen
Huu Duc Nguyen
Thi Le Do
author_sort Thi Nguyet Ha Nguyen
collection DOAJ
description Irradiation is known as a handful measure to inhibit potato sprouting, kill harmful bacteria, and increase preservation. The absorbed dose is one of the essential characteristics of the irradiation process. In this study, the depth-dose distributions in potatoes and polymethyl methacrylate were investigated under low-energy X-ray irradiation by using the Fricke dosimeter and Gafchromic film dosimeter. The dose rates required for the rays to penetrate in polymethyl methacrylate were compared with those in potatoes. Polymethyl methacrylate could be used as a phantom in measuring the depth dose delivered in potatoes. The difference in depth-dose distribution in potatoes between one-sided and double-sided irradiation was also investigated. The calculated dose uniformity ratio values are 5.8 and 1.9 for potatoes irradiating one-sided and double-sided.
first_indexed 2024-04-10T07:25:21Z
format Article
id doaj.art-9eba09742ca9426e94f53ca9b5b8cffc
institution Directory Open Access Journal
issn 1859-1388
2615-9678
language English
last_indexed 2024-04-10T07:25:21Z
publishDate 2022-06-01
publisher HUJOS
record_format Article
series Tạp chí Khoa học Đại học Huế: Khoa học Tự nhiên
spelling doaj.art-9eba09742ca9426e94f53ca9b5b8cffc2023-02-24T07:46:20ZengHUJOSTạp chí Khoa học Đại học Huế: Khoa học Tự nhiên1859-13882615-96782022-06-011311B10.26459/hueunijns.v131i1B.6514Depth-dose distribution in potatoes with low-energy X-raysThi Nguyet Ha Nguyen0Kume Tamikazu1An Son Nguyen2Thi Minh Sang Nguyen3Thi Ngoc Ha Pham4Danh Hung Nguyen5Van Hai Cao6Quang Kien Nguyen7Huu Duc Nguyen8Thi Le Do9Dalat University, 1 Phu Dong Thien Vuong St., Dalat, Vietnam Dalat University, 1 Phu Dong Thien Vuong St., Dalat, VietnamDalat University, 1 Phu Dong Thien Vuong St., Dalat, VietnamDalat University, 1 Phu Dong Thien Vuong St., Dalat, VietnamDalat University, 1 Phu Dong Thien Vuong St., Dalat, VietnamDalat University, 1 Phu Dong Thien Vuong St., Dalat, VietnamDalat University, 1 Phu Dong Thien Vuong St., Dalat, VietnamDalat University, 1 Phu Dong Thien Vuong St., Dalat, VietnamDalat University, 1 Phu Dong Thien Vuong St., Dalat, VietnamDalat University, 1 Phu Dong Thien Vuong St., Dalat, Vietnam Irradiation is known as a handful measure to inhibit potato sprouting, kill harmful bacteria, and increase preservation. The absorbed dose is one of the essential characteristics of the irradiation process. In this study, the depth-dose distributions in potatoes and polymethyl methacrylate were investigated under low-energy X-ray irradiation by using the Fricke dosimeter and Gafchromic film dosimeter. The dose rates required for the rays to penetrate in polymethyl methacrylate were compared with those in potatoes. Polymethyl methacrylate could be used as a phantom in measuring the depth dose delivered in potatoes. The difference in depth-dose distribution in potatoes between one-sided and double-sided irradiation was also investigated. The calculated dose uniformity ratio values are 5.8 and 1.9 for potatoes irradiating one-sided and double-sided. https://jos.hueuni.edu.vn/index.php/hujos-ns/article/view/6514depth dose distributionpotatoGafchromic film dosimeterlow energy X-rays
spellingShingle Thi Nguyet Ha Nguyen
Kume Tamikazu
An Son Nguyen
Thi Minh Sang Nguyen
Thi Ngoc Ha Pham
Danh Hung Nguyen
Van Hai Cao
Quang Kien Nguyen
Huu Duc Nguyen
Thi Le Do
Depth-dose distribution in potatoes with low-energy X-rays
Tạp chí Khoa học Đại học Huế: Khoa học Tự nhiên
depth dose distribution
potato
Gafchromic film dosimeter
low energy X-rays
title Depth-dose distribution in potatoes with low-energy X-rays
title_full Depth-dose distribution in potatoes with low-energy X-rays
title_fullStr Depth-dose distribution in potatoes with low-energy X-rays
title_full_unstemmed Depth-dose distribution in potatoes with low-energy X-rays
title_short Depth-dose distribution in potatoes with low-energy X-rays
title_sort depth dose distribution in potatoes with low energy x rays
topic depth dose distribution
potato
Gafchromic film dosimeter
low energy X-rays
url https://jos.hueuni.edu.vn/index.php/hujos-ns/article/view/6514
work_keys_str_mv AT thinguyethanguyen depthdosedistributioninpotatoeswithlowenergyxrays
AT kumetamikazu depthdosedistributioninpotatoeswithlowenergyxrays
AT ansonnguyen depthdosedistributioninpotatoeswithlowenergyxrays
AT thiminhsangnguyen depthdosedistributioninpotatoeswithlowenergyxrays
AT thingochapham depthdosedistributioninpotatoeswithlowenergyxrays
AT danhhungnguyen depthdosedistributioninpotatoeswithlowenergyxrays
AT vanhaicao depthdosedistributioninpotatoeswithlowenergyxrays
AT quangkiennguyen depthdosedistributioninpotatoeswithlowenergyxrays
AT huuducnguyen depthdosedistributioninpotatoeswithlowenergyxrays
AT thiledo depthdosedistributioninpotatoeswithlowenergyxrays