Accuracy of the Lacrimal Syringing Test in Relation to Dacryocystography and Dacryoendoscopy

Jutaro Nakamura,1,2 Tomoyuki Kamao,1 Arisa Mitani,1 Nobuhisa Mizuki,2 Atsushi Shiraishi1 1Department of Ophthalmology, Ehime University Graduate School of Medicine, Toon, Ehime, 791-0295, Japan; 2Department of Ophthalmology and Visual Science, Yokohama City University Graduate School of Medicine, Yo...

Full description

Bibliographic Details
Main Authors: Nakamura J, Kamao T, Mitani A, Mizuki N, Shiraishi A
Format: Article
Language:English
Published: Dove Medical Press 2023-05-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/accuracy-of-the-lacrimal-syringing-test-in-relation-to-dacryocystograp-peer-reviewed-fulltext-article-OPTH
_version_ 1797833291239260160
author Nakamura J
Kamao T
Mitani A
Mizuki N
Shiraishi A
author_facet Nakamura J
Kamao T
Mitani A
Mizuki N
Shiraishi A
author_sort Nakamura J
collection DOAJ
description Jutaro Nakamura,1,2 Tomoyuki Kamao,1 Arisa Mitani,1 Nobuhisa Mizuki,2 Atsushi Shiraishi1 1Department of Ophthalmology, Ehime University Graduate School of Medicine, Toon, Ehime, 791-0295, Japan; 2Department of Ophthalmology and Visual Science, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa, 236-0004, JapanCorrespondence: Jutaro Nakamura, Department of Ophthalmology, Ehime University Graduate School of Medicine, Toon, Ehime, 791-0295, Japan, Tel +8189-960-5361, Fax +8189-960-5364, Email jutaro_n@yokohama-cu.ac.jpPurpose: This study aimed to evaluate the accuracy of the lacrimal syringing test (syringing) in relation to dacryocystography (DCG) and dacryoendoscopy (DE) in lacrimal pathway (LP) obstruction.Methods: We retrospectively reviewed 101 patients (188 LPs) who underwent syringing, cone-beam computed tomography (CBCT)-DCG, and DE to diagnose the degree and site of LP obstruction. The degree of obstruction was classified into patent, partial obstruction, and complete obstruction. The degree of LP obstruction was determined by combining the findings of DE and CBCT-DCG and was designated as DCG+DE. When differentiating complete or partial obstruction on DE was uncertain, complete or partial obstruction was assigned if the DCG showed evidence of contrast media obstruction or passage, respectively. The consistency between syringing and DCG+DE was evaluated by calculating the weighted kappa coefficient.Results: The sensitivity and specificity of syringing were 94% and 89%, respectively. The weighted Cohen’s kappa value of agreement between syringing and DCG+DE was κ = 0.73 (SE = 0.04, 95% confidence interval [CI]: 0.66– 0.80, p < 0.01). When divided into presaccal and postsaccal obstruction categories, the kappa values were κ = 0.40 (SE = 0.11, 95% CI: 0.19– 0.62, p < 0.01) and 0.55 (SE = 0.09, 95% CI: 0.37– 0.73, p < 0.01), respectively. Furthermore, when limited to common canaliculus obstruction (stenoses), which accounted for 78% (46 LPs) of the total presaccal obstructions, the kappa value was κ = 0.29 (SE = 0.12, 95% CI: 0.05– 0.54, p = 0.021), which demonstrated the lowest consistency between syringing and DCG+DE.Conclusion: Syringing was “substantially” in agreement with DCG+DE in detecting the degree of LP obstruction. Moreover, syringing was a sufficiently sensitive and specific test when performed by an experienced clinician. However, distinguishing between complete and partial obstructions by syringing was sometimes difficult, particularly in the common canaliculus obstruction (stenosis).Keywords: epiphora, nasolacrimal duct, lacrimal passage obstruction, stenosis, lacrimal drainage system, lacrimal sac, lacrimal syringing, irrigation, dacryocystography, dacryoendoscopy, weighted kappa coefficient
first_indexed 2024-04-09T14:20:50Z
format Article
id doaj.art-9ef2126dc1be4d938e8e8ff82685d5e9
institution Directory Open Access Journal
issn 1177-5483
language English
last_indexed 2024-04-09T14:20:50Z
publishDate 2023-05-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj.art-9ef2126dc1be4d938e8e8ff82685d5e92023-05-04T19:14:20ZengDove Medical PressClinical Ophthalmology1177-54832023-05-01Volume 171277128583472Accuracy of the Lacrimal Syringing Test in Relation to Dacryocystography and DacryoendoscopyNakamura JKamao TMitani AMizuki NShiraishi AJutaro Nakamura,1,2 Tomoyuki Kamao,1 Arisa Mitani,1 Nobuhisa Mizuki,2 Atsushi Shiraishi1 1Department of Ophthalmology, Ehime University Graduate School of Medicine, Toon, Ehime, 791-0295, Japan; 2Department of Ophthalmology and Visual Science, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa, 236-0004, JapanCorrespondence: Jutaro Nakamura, Department of Ophthalmology, Ehime University Graduate School of Medicine, Toon, Ehime, 791-0295, Japan, Tel +8189-960-5361, Fax +8189-960-5364, Email jutaro_n@yokohama-cu.ac.jpPurpose: This study aimed to evaluate the accuracy of the lacrimal syringing test (syringing) in relation to dacryocystography (DCG) and dacryoendoscopy (DE) in lacrimal pathway (LP) obstruction.Methods: We retrospectively reviewed 101 patients (188 LPs) who underwent syringing, cone-beam computed tomography (CBCT)-DCG, and DE to diagnose the degree and site of LP obstruction. The degree of obstruction was classified into patent, partial obstruction, and complete obstruction. The degree of LP obstruction was determined by combining the findings of DE and CBCT-DCG and was designated as DCG+DE. When differentiating complete or partial obstruction on DE was uncertain, complete or partial obstruction was assigned if the DCG showed evidence of contrast media obstruction or passage, respectively. The consistency between syringing and DCG+DE was evaluated by calculating the weighted kappa coefficient.Results: The sensitivity and specificity of syringing were 94% and 89%, respectively. The weighted Cohen’s kappa value of agreement between syringing and DCG+DE was κ = 0.73 (SE = 0.04, 95% confidence interval [CI]: 0.66– 0.80, p < 0.01). When divided into presaccal and postsaccal obstruction categories, the kappa values were κ = 0.40 (SE = 0.11, 95% CI: 0.19– 0.62, p < 0.01) and 0.55 (SE = 0.09, 95% CI: 0.37– 0.73, p < 0.01), respectively. Furthermore, when limited to common canaliculus obstruction (stenoses), which accounted for 78% (46 LPs) of the total presaccal obstructions, the kappa value was κ = 0.29 (SE = 0.12, 95% CI: 0.05– 0.54, p = 0.021), which demonstrated the lowest consistency between syringing and DCG+DE.Conclusion: Syringing was “substantially” in agreement with DCG+DE in detecting the degree of LP obstruction. Moreover, syringing was a sufficiently sensitive and specific test when performed by an experienced clinician. However, distinguishing between complete and partial obstructions by syringing was sometimes difficult, particularly in the common canaliculus obstruction (stenosis).Keywords: epiphora, nasolacrimal duct, lacrimal passage obstruction, stenosis, lacrimal drainage system, lacrimal sac, lacrimal syringing, irrigation, dacryocystography, dacryoendoscopy, weighted kappa coefficienthttps://www.dovepress.com/accuracy-of-the-lacrimal-syringing-test-in-relation-to-dacryocystograp-peer-reviewed-fulltext-article-OPTHepiphoranasolacrimal ductlacrimal passage obstructionstenosislacrimal drainage systemlacrimal saclacrimal syringingirrigationdacryocystographydacryoendoscopyweighted kappa coefficient
spellingShingle Nakamura J
Kamao T
Mitani A
Mizuki N
Shiraishi A
Accuracy of the Lacrimal Syringing Test in Relation to Dacryocystography and Dacryoendoscopy
Clinical Ophthalmology
epiphora
nasolacrimal duct
lacrimal passage obstruction
stenosis
lacrimal drainage system
lacrimal sac
lacrimal syringing
irrigation
dacryocystography
dacryoendoscopy
weighted kappa coefficient
title Accuracy of the Lacrimal Syringing Test in Relation to Dacryocystography and Dacryoendoscopy
title_full Accuracy of the Lacrimal Syringing Test in Relation to Dacryocystography and Dacryoendoscopy
title_fullStr Accuracy of the Lacrimal Syringing Test in Relation to Dacryocystography and Dacryoendoscopy
title_full_unstemmed Accuracy of the Lacrimal Syringing Test in Relation to Dacryocystography and Dacryoendoscopy
title_short Accuracy of the Lacrimal Syringing Test in Relation to Dacryocystography and Dacryoendoscopy
title_sort accuracy of the lacrimal syringing test in relation to dacryocystography and dacryoendoscopy
topic epiphora
nasolacrimal duct
lacrimal passage obstruction
stenosis
lacrimal drainage system
lacrimal sac
lacrimal syringing
irrigation
dacryocystography
dacryoendoscopy
weighted kappa coefficient
url https://www.dovepress.com/accuracy-of-the-lacrimal-syringing-test-in-relation-to-dacryocystograp-peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT nakamuraj accuracyofthelacrimalsyringingtestinrelationtodacryocystographyanddacryoendoscopy
AT kamaot accuracyofthelacrimalsyringingtestinrelationtodacryocystographyanddacryoendoscopy
AT mitania accuracyofthelacrimalsyringingtestinrelationtodacryocystographyanddacryoendoscopy
AT mizukin accuracyofthelacrimalsyringingtestinrelationtodacryocystographyanddacryoendoscopy
AT shiraishia accuracyofthelacrimalsyringingtestinrelationtodacryocystographyanddacryoendoscopy