Control strategy for DC capacitance of mine-used cascaded high voltage inverter
In view of problem of large volume of DC capacitor of high voltage inverter cascaded in H-bridge type, a kind of control strategy to minimize DC capacitance by injecting the third-order harmonic into fundamental modulation signal was proposed. The DC capacitor voltage ripple was reduced because part...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Department of Industry and Mine Automation
2014-07-01
|
Series: | Gong-kuang zidonghua |
Subjects: | |
Online Access: | http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.07.020 |
_version_ | 1797868719244836864 |
---|---|
author | GUO Ruidong ZHANG Jingjing XIONG Wanqi JIN Lei ZHENG Jie |
author_facet | GUO Ruidong ZHANG Jingjing XIONG Wanqi JIN Lei ZHENG Jie |
author_sort | GUO Ruidong |
collection | DOAJ |
description | In view of problem of large volume of DC capacitor of high voltage inverter cascaded in H-bridge type, a kind of control strategy to minimize DC capacitance by injecting the third-order harmonic into fundamental modulation signal was proposed. The DC capacitor voltage ripple was reduced because part of the low-order harmonic of DC capacitor current was equivalently converted to high-order harmonic when the total modulation index remained the same. The relationship of harmonic content of DC capacitor current and the third-order harmonic injection amount was derived, and the expression of the maximum third-order harmonic injection amount under different power factors was presented. Matlab/Simulink simulation results show that the DC capacitance achieves 24.2% reduction under typical load with 0.85 power factor, which verifies feasibility and effectiveness of the control strategy. |
first_indexed | 2024-04-10T00:00:17Z |
format | Article |
id | doaj.art-9ef98ad245324e1084e2c10de8609aaf |
institution | Directory Open Access Journal |
issn | 1671-251X |
language | zho |
last_indexed | 2024-04-10T00:00:17Z |
publishDate | 2014-07-01 |
publisher | Editorial Department of Industry and Mine Automation |
record_format | Article |
series | Gong-kuang zidonghua |
spelling | doaj.art-9ef98ad245324e1084e2c10de8609aaf2023-03-17T01:51:31ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2014-07-01407767910.13272/j.issn.1671-251x.2014.07.020Control strategy for DC capacitance of mine-used cascaded high voltage inverterGUO Ruidong0ZHANG Jingjing1XIONG Wanqi2JIN Lei3ZHENG Jie4College of Electrical Engineering and Automation, Anhui University, Hefei 230601, ChinaCollege of Electrical Engineering and Automation, Anhui University, Hefei 230601, ChinaCollege of Electrical Engineering and Automation, Anhui University, Hefei 230601, ChinaShanghai Harbor Commercial Construction Development Co., Ltd., Shanghai 201315, ChinaCollege of Electrical Engineering and Automation, Anhui University, Hefei 230601, ChinaIn view of problem of large volume of DC capacitor of high voltage inverter cascaded in H-bridge type, a kind of control strategy to minimize DC capacitance by injecting the third-order harmonic into fundamental modulation signal was proposed. The DC capacitor voltage ripple was reduced because part of the low-order harmonic of DC capacitor current was equivalently converted to high-order harmonic when the total modulation index remained the same. The relationship of harmonic content of DC capacitor current and the third-order harmonic injection amount was derived, and the expression of the maximum third-order harmonic injection amount under different power factors was presented. Matlab/Simulink simulation results show that the DC capacitance achieves 24.2% reduction under typical load with 0.85 power factor, which verifies feasibility and effectiveness of the control strategy.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.07.020high voltage inverterdc capacitorthird-order harmonic injectiontypical load |
spellingShingle | GUO Ruidong ZHANG Jingjing XIONG Wanqi JIN Lei ZHENG Jie Control strategy for DC capacitance of mine-used cascaded high voltage inverter Gong-kuang zidonghua high voltage inverter dc capacitor third-order harmonic injection typical load |
title | Control strategy for DC capacitance of mine-used cascaded high voltage inverter |
title_full | Control strategy for DC capacitance of mine-used cascaded high voltage inverter |
title_fullStr | Control strategy for DC capacitance of mine-used cascaded high voltage inverter |
title_full_unstemmed | Control strategy for DC capacitance of mine-used cascaded high voltage inverter |
title_short | Control strategy for DC capacitance of mine-used cascaded high voltage inverter |
title_sort | control strategy for dc capacitance of mine used cascaded high voltage inverter |
topic | high voltage inverter dc capacitor third-order harmonic injection typical load |
url | http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.07.020 |
work_keys_str_mv | AT guoruidong controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter AT zhangjingjing controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter AT xiongwanqi controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter AT jinlei controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter AT zhengjie controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter |