Control strategy for DC capacitance of mine-used cascaded high voltage inverter

In view of problem of large volume of DC capacitor of high voltage inverter cascaded in H-bridge type, a kind of control strategy to minimize DC capacitance by injecting the third-order harmonic into fundamental modulation signal was proposed. The DC capacitor voltage ripple was reduced because part...

Full description

Bibliographic Details
Main Authors: GUO Ruidong, ZHANG Jingjing, XIONG Wanqi, JIN Lei, ZHENG Jie
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2014-07-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.07.020
_version_ 1797868719244836864
author GUO Ruidong
ZHANG Jingjing
XIONG Wanqi
JIN Lei
ZHENG Jie
author_facet GUO Ruidong
ZHANG Jingjing
XIONG Wanqi
JIN Lei
ZHENG Jie
author_sort GUO Ruidong
collection DOAJ
description In view of problem of large volume of DC capacitor of high voltage inverter cascaded in H-bridge type, a kind of control strategy to minimize DC capacitance by injecting the third-order harmonic into fundamental modulation signal was proposed. The DC capacitor voltage ripple was reduced because part of the low-order harmonic of DC capacitor current was equivalently converted to high-order harmonic when the total modulation index remained the same. The relationship of harmonic content of DC capacitor current and the third-order harmonic injection amount was derived, and the expression of the maximum third-order harmonic injection amount under different power factors was presented. Matlab/Simulink simulation results show that the DC capacitance achieves 24.2% reduction under typical load with 0.85 power factor, which verifies feasibility and effectiveness of the control strategy.
first_indexed 2024-04-10T00:00:17Z
format Article
id doaj.art-9ef98ad245324e1084e2c10de8609aaf
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-10T00:00:17Z
publishDate 2014-07-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-9ef98ad245324e1084e2c10de8609aaf2023-03-17T01:51:31ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2014-07-01407767910.13272/j.issn.1671-251x.2014.07.020Control strategy for DC capacitance of mine-used cascaded high voltage inverterGUO Ruidong0ZHANG Jingjing1XIONG Wanqi2JIN Lei3ZHENG Jie4College of Electrical Engineering and Automation, Anhui University, Hefei 230601, ChinaCollege of Electrical Engineering and Automation, Anhui University, Hefei 230601, ChinaCollege of Electrical Engineering and Automation, Anhui University, Hefei 230601, ChinaShanghai Harbor Commercial Construction Development Co., Ltd., Shanghai 201315, ChinaCollege of Electrical Engineering and Automation, Anhui University, Hefei 230601, ChinaIn view of problem of large volume of DC capacitor of high voltage inverter cascaded in H-bridge type, a kind of control strategy to minimize DC capacitance by injecting the third-order harmonic into fundamental modulation signal was proposed. The DC capacitor voltage ripple was reduced because part of the low-order harmonic of DC capacitor current was equivalently converted to high-order harmonic when the total modulation index remained the same. The relationship of harmonic content of DC capacitor current and the third-order harmonic injection amount was derived, and the expression of the maximum third-order harmonic injection amount under different power factors was presented. Matlab/Simulink simulation results show that the DC capacitance achieves 24.2% reduction under typical load with 0.85 power factor, which verifies feasibility and effectiveness of the control strategy.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.07.020high voltage inverterdc capacitorthird-order harmonic injectiontypical load
spellingShingle GUO Ruidong
ZHANG Jingjing
XIONG Wanqi
JIN Lei
ZHENG Jie
Control strategy for DC capacitance of mine-used cascaded high voltage inverter
Gong-kuang zidonghua
high voltage inverter
dc capacitor
third-order harmonic injection
typical load
title Control strategy for DC capacitance of mine-used cascaded high voltage inverter
title_full Control strategy for DC capacitance of mine-used cascaded high voltage inverter
title_fullStr Control strategy for DC capacitance of mine-used cascaded high voltage inverter
title_full_unstemmed Control strategy for DC capacitance of mine-used cascaded high voltage inverter
title_short Control strategy for DC capacitance of mine-used cascaded high voltage inverter
title_sort control strategy for dc capacitance of mine used cascaded high voltage inverter
topic high voltage inverter
dc capacitor
third-order harmonic injection
typical load
url http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.07.020
work_keys_str_mv AT guoruidong controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter
AT zhangjingjing controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter
AT xiongwanqi controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter
AT jinlei controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter
AT zhengjie controlstrategyfordccapacitanceofmineusedcascadedhighvoltageinverter