Identification of Reservoir Distribution Using Extended Elastic Impedance (EEI) Inversion in the "Z" Field of the Kutai Basin
This research was conducted using EEI inversion on seismic data in Z Field, Kutai Basin. The EEI inversion is effectively used to determine the reservoir distribution by eliminating the angle limit on the elastic impedance to the Chi angle so that it can be correlated with petrophysical parameters...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Islam Riau (UIR) Press
2023-08-01
|
Series: | Journal of Earth Energy Engineering |
Subjects: | |
Online Access: | https://journal.uir.ac.id/index.php/JEEE/article/view/13955 |
_version_ | 1797360397745913856 |
---|---|
author | Zikra Miftahul Haq Eki Komara Wien Lestari |
author_facet | Zikra Miftahul Haq Eki Komara Wien Lestari |
author_sort | Zikra Miftahul Haq |
collection | DOAJ |
description |
This research was conducted using EEI inversion on seismic data in Z Field, Kutai Basin. The EEI inversion is effectively used to determine the reservoir distribution by eliminating the angle limit on the elastic impedance to the Chi angle so that it can be correlated with petrophysical parameters that are sensitive to lithology and fluids. The data used in this study are well data, checkshots, horizons, and partial-stack angle gather 3D seismic data. The data obtained is processed to obtain the target zone first based on log interpretation. Based on data processing, the target zone is obtained at 1513 m to 1531 m. Sensitivity analysis was conducted to determine the sensitive parameters, which can separate the lithology of the formation. In the sensitivity analysis, the most sensitive log to separate lithology is the Vp/VS log, which can separate sandstone, shale, and coal. Furthermore, the EEI inversion analysis was carried out to obtain the most suiTable model for the inversion, the Based Hard Constraint model was obtained with a correlation reaching 0.997 and an error value of 0.078. Based on the EEI inversion, the target zone in the Z-field at a depth of 1258 ms - 1269 ms with a sandstone reservoir in the EEI range of 6000 (m/s)(g/cc) - 7500 (m/s)(g/cc) which spreads from northeast to south. The distribution of the sandstone reservoir is surrounded by coal with a range of EEI 7500 (m/s)(g/cc) - 12000 (m/s)(g/cc), and also the distribution of shale in the EEI range of 7500(m/s)( g/cc) - 9200(m/s)(g/cc).
|
first_indexed | 2024-03-08T15:38:56Z |
format | Article |
id | doaj.art-9f1e804ca59744b99c5864e6443c8076 |
institution | Directory Open Access Journal |
issn | 2301-8097 2540-9352 |
language | English |
last_indexed | 2024-03-08T15:38:56Z |
publishDate | 2023-08-01 |
publisher | Universitas Islam Riau (UIR) Press |
record_format | Article |
series | Journal of Earth Energy Engineering |
spelling | doaj.art-9f1e804ca59744b99c5864e6443c80762024-01-09T16:47:40ZengUniversitas Islam Riau (UIR) PressJournal of Earth Energy Engineering2301-80972540-93522023-08-01122s10.25299/jeee.2023.13955Identification of Reservoir Distribution Using Extended Elastic Impedance (EEI) Inversion in the "Z" Field of the Kutai BasinZikra Miftahul Haq0Eki Komara1Wien Lestari2Geophysical Engineering Department, Institut Teknologi Sepuluh Nopember, Surabaya, IndonesiaGeophysical Engineering Department, Institut Teknologi Sepuluh Nopember, Surabaya, IndonesiaGeophysical Engineering Department, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia This research was conducted using EEI inversion on seismic data in Z Field, Kutai Basin. The EEI inversion is effectively used to determine the reservoir distribution by eliminating the angle limit on the elastic impedance to the Chi angle so that it can be correlated with petrophysical parameters that are sensitive to lithology and fluids. The data used in this study are well data, checkshots, horizons, and partial-stack angle gather 3D seismic data. The data obtained is processed to obtain the target zone first based on log interpretation. Based on data processing, the target zone is obtained at 1513 m to 1531 m. Sensitivity analysis was conducted to determine the sensitive parameters, which can separate the lithology of the formation. In the sensitivity analysis, the most sensitive log to separate lithology is the Vp/VS log, which can separate sandstone, shale, and coal. Furthermore, the EEI inversion analysis was carried out to obtain the most suiTable model for the inversion, the Based Hard Constraint model was obtained with a correlation reaching 0.997 and an error value of 0.078. Based on the EEI inversion, the target zone in the Z-field at a depth of 1258 ms - 1269 ms with a sandstone reservoir in the EEI range of 6000 (m/s)(g/cc) - 7500 (m/s)(g/cc) which spreads from northeast to south. The distribution of the sandstone reservoir is surrounded by coal with a range of EEI 7500 (m/s)(g/cc) - 12000 (m/s)(g/cc), and also the distribution of shale in the EEI range of 7500(m/s)( g/cc) - 9200(m/s)(g/cc). https://journal.uir.ac.id/index.php/JEEE/article/view/13955Chi AngleExtended Elastic ImpedanceInversionKutai BasinReservoir Distribution |
spellingShingle | Zikra Miftahul Haq Eki Komara Wien Lestari Identification of Reservoir Distribution Using Extended Elastic Impedance (EEI) Inversion in the "Z" Field of the Kutai Basin Journal of Earth Energy Engineering Chi Angle Extended Elastic Impedance Inversion Kutai Basin Reservoir Distribution |
title | Identification of Reservoir Distribution Using Extended Elastic Impedance (EEI) Inversion in the "Z" Field of the Kutai Basin |
title_full | Identification of Reservoir Distribution Using Extended Elastic Impedance (EEI) Inversion in the "Z" Field of the Kutai Basin |
title_fullStr | Identification of Reservoir Distribution Using Extended Elastic Impedance (EEI) Inversion in the "Z" Field of the Kutai Basin |
title_full_unstemmed | Identification of Reservoir Distribution Using Extended Elastic Impedance (EEI) Inversion in the "Z" Field of the Kutai Basin |
title_short | Identification of Reservoir Distribution Using Extended Elastic Impedance (EEI) Inversion in the "Z" Field of the Kutai Basin |
title_sort | identification of reservoir distribution using extended elastic impedance eei inversion in the z field of the kutai basin |
topic | Chi Angle Extended Elastic Impedance Inversion Kutai Basin Reservoir Distribution |
url | https://journal.uir.ac.id/index.php/JEEE/article/view/13955 |
work_keys_str_mv | AT zikramiftahulhaq identificationofreservoirdistributionusingextendedelasticimpedanceeeiinversioninthezfieldofthekutaibasin AT ekikomara identificationofreservoirdistributionusingextendedelasticimpedanceeeiinversioninthezfieldofthekutaibasin AT wienlestari identificationofreservoirdistributionusingextendedelasticimpedanceeeiinversioninthezfieldofthekutaibasin |