Proportional‐resonant based control strategy for grid‐connected packed‐E cell inverters with Lyapunov filter‐based PLL

Abstract A proportional‐resonant (PR)‐based current control strategy for grid‐connected packed‐E cell (PEC) inverter is presented. Unlike the existing control strategies, which are based on proportional‐integral controller, developed for packed‐U cell and PEC inverters, the proposed PR‐based control...

Full description

Bibliographic Details
Main Authors: Samet Biricik, Hasan Komurcugil, Hafiz Ahmed, Mohammad Sharifzadeh, Majid Mehrasa, Kamal Al‐Haddad
Format: Article
Language:English
Published: Wiley 2023-02-01
Series:IET Generation, Transmission & Distribution
Online Access:https://doi.org/10.1049/gtd2.12607
_version_ 1811173489692901376
author Samet Biricik
Hasan Komurcugil
Hafiz Ahmed
Mohammad Sharifzadeh
Majid Mehrasa
Kamal Al‐Haddad
author_facet Samet Biricik
Hasan Komurcugil
Hafiz Ahmed
Mohammad Sharifzadeh
Majid Mehrasa
Kamal Al‐Haddad
author_sort Samet Biricik
collection DOAJ
description Abstract A proportional‐resonant (PR)‐based current control strategy for grid‐connected packed‐E cell (PEC) inverter is presented. Unlike the existing control strategies, which are based on proportional‐integral controller, developed for packed‐U cell and PEC inverters, the proposed PR‐based control strategy achieves zero steady‐state error in the grid current. Furthermore, it eliminates the necessity of employing the control loop for regulating the dc capacitor voltages. Also, the grid current synchronization is achieved by using a Lyapunov filter‐based phase locked loop (PLL). The consequence of using Lyapunov filter‐based PLL is that sinusoidal synchronization signal can be extracted from the distorted grid voltage. The performances of the proposed control strategy under steady‐state, load variation and non‐ideal grid voltage are investigated on a laboratory‐scale experimental prototype. It is reported that the control of both dc‐ and ac‐side variables of the system are accomplished.
first_indexed 2024-04-10T17:48:54Z
format Article
id doaj.art-9f4ec3d453c54c79abd37a01fe578660
institution Directory Open Access Journal
issn 1751-8687
1751-8695
language English
last_indexed 2024-04-10T17:48:54Z
publishDate 2023-02-01
publisher Wiley
record_format Article
series IET Generation, Transmission & Distribution
spelling doaj.art-9f4ec3d453c54c79abd37a01fe5786602023-02-03T04:08:34ZengWileyIET Generation, Transmission & Distribution1751-86871751-86952023-02-0117364565410.1049/gtd2.12607Proportional‐resonant based control strategy for grid‐connected packed‐E cell inverters with Lyapunov filter‐based PLLSamet Biricik0Hasan Komurcugil1Hafiz Ahmed2Mohammad Sharifzadeh3Majid Mehrasa4Kamal Al‐Haddad5Department of Electrical and Electronic Engineering European University of Lefke Lefke TurkeyDepartment of Computer Engineering Eastern Mediterranean University (EMU) Famagusta Mersin 10 TurkeyNuclear Futures Institute Bangor University Bangor Gwynedd UKÉcole de Technologie Supérieure University of Quebec Montreal QC CanadaUniversité Grenoble Alpes G2Elab Grenoble FranceÉcole de Technologie Supérieure University of Quebec Montreal QC CanadaAbstract A proportional‐resonant (PR)‐based current control strategy for grid‐connected packed‐E cell (PEC) inverter is presented. Unlike the existing control strategies, which are based on proportional‐integral controller, developed for packed‐U cell and PEC inverters, the proposed PR‐based control strategy achieves zero steady‐state error in the grid current. Furthermore, it eliminates the necessity of employing the control loop for regulating the dc capacitor voltages. Also, the grid current synchronization is achieved by using a Lyapunov filter‐based phase locked loop (PLL). The consequence of using Lyapunov filter‐based PLL is that sinusoidal synchronization signal can be extracted from the distorted grid voltage. The performances of the proposed control strategy under steady‐state, load variation and non‐ideal grid voltage are investigated on a laboratory‐scale experimental prototype. It is reported that the control of both dc‐ and ac‐side variables of the system are accomplished.https://doi.org/10.1049/gtd2.12607
spellingShingle Samet Biricik
Hasan Komurcugil
Hafiz Ahmed
Mohammad Sharifzadeh
Majid Mehrasa
Kamal Al‐Haddad
Proportional‐resonant based control strategy for grid‐connected packed‐E cell inverters with Lyapunov filter‐based PLL
IET Generation, Transmission & Distribution
title Proportional‐resonant based control strategy for grid‐connected packed‐E cell inverters with Lyapunov filter‐based PLL
title_full Proportional‐resonant based control strategy for grid‐connected packed‐E cell inverters with Lyapunov filter‐based PLL
title_fullStr Proportional‐resonant based control strategy for grid‐connected packed‐E cell inverters with Lyapunov filter‐based PLL
title_full_unstemmed Proportional‐resonant based control strategy for grid‐connected packed‐E cell inverters with Lyapunov filter‐based PLL
title_short Proportional‐resonant based control strategy for grid‐connected packed‐E cell inverters with Lyapunov filter‐based PLL
title_sort proportional resonant based control strategy for grid connected packed e cell inverters with lyapunov filter based pll
url https://doi.org/10.1049/gtd2.12607
work_keys_str_mv AT sametbiricik proportionalresonantbasedcontrolstrategyforgridconnectedpackedecellinverterswithlyapunovfilterbasedpll
AT hasankomurcugil proportionalresonantbasedcontrolstrategyforgridconnectedpackedecellinverterswithlyapunovfilterbasedpll
AT hafizahmed proportionalresonantbasedcontrolstrategyforgridconnectedpackedecellinverterswithlyapunovfilterbasedpll
AT mohammadsharifzadeh proportionalresonantbasedcontrolstrategyforgridconnectedpackedecellinverterswithlyapunovfilterbasedpll
AT majidmehrasa proportionalresonantbasedcontrolstrategyforgridconnectedpackedecellinverterswithlyapunovfilterbasedpll
AT kamalalhaddad proportionalresonantbasedcontrolstrategyforgridconnectedpackedecellinverterswithlyapunovfilterbasedpll