Calculation of temperature field of coiled wire using EFM
Provided a heat transfer model of coiled wire method. Based on the method, a software of EFM (ANSYS) was used to calculate the temperature field of coiled wire. Comparisons between the experimental of RVS coiled wire and numerical results indicated the effectiveness of the method utilized. The simul...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://doi.org/10.1051/e3sconf/20187203002 |
_version_ | 1818916765862723584 |
---|---|
author | Shu Zhongjun Shen Wei Li Qiang Fan Minghao Zhang Jiaqing |
author_facet | Shu Zhongjun Shen Wei Li Qiang Fan Minghao Zhang Jiaqing |
author_sort | Shu Zhongjun |
collection | DOAJ |
description | Provided a heat transfer model of coiled wire method. Based on the method, a software of EFM (ANSYS) was used to calculate the temperature field of coiled wire. Comparisons between the experimental of RVS coiled wire and numerical results indicated the effectiveness of the method utilized. The simulation method based on EFM proved to be useful for the fire risk assessment of coiled wire. |
first_indexed | 2024-12-20T00:23:23Z |
format | Article |
id | doaj.art-9f604c8a1b414b87b49156ac3fc6cf0f |
institution | Directory Open Access Journal |
issn | 2267-1242 |
language | English |
last_indexed | 2024-12-20T00:23:23Z |
publishDate | 2018-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | E3S Web of Conferences |
spelling | doaj.art-9f604c8a1b414b87b49156ac3fc6cf0f2022-12-21T20:00:07ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01720300210.1051/e3sconf/20187203002e3sconf_ceege2018_03002Calculation of temperature field of coiled wire using EFMShu Zhongjun0Shen Wei1Li Qiang2Fan Minghao3Zhang Jiaqing4Chinese People’s Armed Police Academy, Department of Fire Protection EngineeringState Grid Anhui Electric Power Research InstituteChinese People’s Armed Police Academy, Department of Fire Protection EngineeringState Grid Anhui Electric Power Research InstituteState Grid Anhui Electric Power Research InstituteProvided a heat transfer model of coiled wire method. Based on the method, a software of EFM (ANSYS) was used to calculate the temperature field of coiled wire. Comparisons between the experimental of RVS coiled wire and numerical results indicated the effectiveness of the method utilized. The simulation method based on EFM proved to be useful for the fire risk assessment of coiled wire.https://doi.org/10.1051/e3sconf/20187203002 |
spellingShingle | Shu Zhongjun Shen Wei Li Qiang Fan Minghao Zhang Jiaqing Calculation of temperature field of coiled wire using EFM E3S Web of Conferences |
title | Calculation of temperature field of coiled wire using EFM |
title_full | Calculation of temperature field of coiled wire using EFM |
title_fullStr | Calculation of temperature field of coiled wire using EFM |
title_full_unstemmed | Calculation of temperature field of coiled wire using EFM |
title_short | Calculation of temperature field of coiled wire using EFM |
title_sort | calculation of temperature field of coiled wire using efm |
url | https://doi.org/10.1051/e3sconf/20187203002 |
work_keys_str_mv | AT shuzhongjun calculationoftemperaturefieldofcoiledwireusingefm AT shenwei calculationoftemperaturefieldofcoiledwireusingefm AT liqiang calculationoftemperaturefieldofcoiledwireusingefm AT fanminghao calculationoftemperaturefieldofcoiledwireusingefm AT zhangjiaqing calculationoftemperaturefieldofcoiledwireusingefm |