Research on chemical oxygen demand based on laser Fluorescence-Raman spectroscopy

In this invited paper, a novel water chemical oxygen demand (COD) detection method based on laser spectroscopy is proposed, and the COD value is obtained according to the intensity ratio of laser Fluorescence-Raman signal produced by laser incident into water. Based on the laser Fluorescence-Raman r...

Full description

Bibliographic Details
Main Authors: Xiaohua Che, Zhaoshuo Tian, Fenghao Sun, Qingcao Liu, Zongjie Bi, Hao Chen, Zihao Cui
Format: Article
Language:English
Published: Frontiers Media S.A. 2022-11-01
Series:Frontiers in Physics
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fphy.2022.1055049/full
_version_ 1797991433078046720
author Xiaohua Che
Zhaoshuo Tian
Fenghao Sun
Qingcao Liu
Zongjie Bi
Hao Chen
Zihao Cui
author_facet Xiaohua Che
Zhaoshuo Tian
Fenghao Sun
Qingcao Liu
Zongjie Bi
Hao Chen
Zihao Cui
author_sort Xiaohua Che
collection DOAJ
description In this invited paper, a novel water chemical oxygen demand (COD) detection method based on laser spectroscopy is proposed, and the COD value is obtained according to the intensity ratio of laser Fluorescence-Raman signal produced by laser incident into water. Based on the laser Fluorescence-Raman ratio (LFRR) method, we design a portable water quality measurement system. In which, a 405 nm semiconductor laser is used as the light source. The laser is coupled into the delivering port of Y-type fiber and then transmitted into water. The generated Mie scattered light, water Raman light and corresponding fluorescence are received and transmitted into spectrometer through the detecting port of Y-type fiber, and the COD value can be obtained by analyzing the LFRR of water spectra. The mixed solution of sodium humate and glucose is used as the COD standard solution to calibrate the designed system. The experiment results show that the optimal volume ratio of the two solutions is 1:29. When the COD of standard solutions is in the 1–12 mg/L concentration range, a good linear relationship can be found between the COD value and LFRR value with a correlation coefficient of 0.974. In addition, the COD of natural water samples are measured with LFRR method, the results of which are consistent with COD values obtained by rapid digestion spectrophotometry. Meanwhile, experimental results prove that the COD detection method proposed in this paper has the advantages of high sensitivity, high precision, high detection speed and simplicity, which can be widely used in various water areas for real-time COD monitoring.
first_indexed 2024-04-11T08:51:06Z
format Article
id doaj.art-9f81360fc69d48a98f3d237a241f83e0
institution Directory Open Access Journal
issn 2296-424X
language English
last_indexed 2024-04-11T08:51:06Z
publishDate 2022-11-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Physics
spelling doaj.art-9f81360fc69d48a98f3d237a241f83e02022-12-22T04:33:34ZengFrontiers Media S.A.Frontiers in Physics2296-424X2022-11-011010.3389/fphy.2022.10550491055049Research on chemical oxygen demand based on laser Fluorescence-Raman spectroscopyXiaohua CheZhaoshuo TianFenghao SunQingcao LiuZongjie BiHao ChenZihao CuiIn this invited paper, a novel water chemical oxygen demand (COD) detection method based on laser spectroscopy is proposed, and the COD value is obtained according to the intensity ratio of laser Fluorescence-Raman signal produced by laser incident into water. Based on the laser Fluorescence-Raman ratio (LFRR) method, we design a portable water quality measurement system. In which, a 405 nm semiconductor laser is used as the light source. The laser is coupled into the delivering port of Y-type fiber and then transmitted into water. The generated Mie scattered light, water Raman light and corresponding fluorescence are received and transmitted into spectrometer through the detecting port of Y-type fiber, and the COD value can be obtained by analyzing the LFRR of water spectra. The mixed solution of sodium humate and glucose is used as the COD standard solution to calibrate the designed system. The experiment results show that the optimal volume ratio of the two solutions is 1:29. When the COD of standard solutions is in the 1–12 mg/L concentration range, a good linear relationship can be found between the COD value and LFRR value with a correlation coefficient of 0.974. In addition, the COD of natural water samples are measured with LFRR method, the results of which are consistent with COD values obtained by rapid digestion spectrophotometry. Meanwhile, experimental results prove that the COD detection method proposed in this paper has the advantages of high sensitivity, high precision, high detection speed and simplicity, which can be widely used in various water areas for real-time COD monitoring.https://www.frontiersin.org/articles/10.3389/fphy.2022.1055049/fullchemical oxygen demandy-type fiberspectroscopyfluorescenceRaman laser405 nm laser
spellingShingle Xiaohua Che
Zhaoshuo Tian
Fenghao Sun
Qingcao Liu
Zongjie Bi
Hao Chen
Zihao Cui
Research on chemical oxygen demand based on laser Fluorescence-Raman spectroscopy
Frontiers in Physics
chemical oxygen demand
y-type fiber
spectroscopy
fluorescence
Raman laser
405 nm laser
title Research on chemical oxygen demand based on laser Fluorescence-Raman spectroscopy
title_full Research on chemical oxygen demand based on laser Fluorescence-Raman spectroscopy
title_fullStr Research on chemical oxygen demand based on laser Fluorescence-Raman spectroscopy
title_full_unstemmed Research on chemical oxygen demand based on laser Fluorescence-Raman spectroscopy
title_short Research on chemical oxygen demand based on laser Fluorescence-Raman spectroscopy
title_sort research on chemical oxygen demand based on laser fluorescence raman spectroscopy
topic chemical oxygen demand
y-type fiber
spectroscopy
fluorescence
Raman laser
405 nm laser
url https://www.frontiersin.org/articles/10.3389/fphy.2022.1055049/full
work_keys_str_mv AT xiaohuache researchonchemicaloxygendemandbasedonlaserfluorescenceramanspectroscopy
AT zhaoshuotian researchonchemicaloxygendemandbasedonlaserfluorescenceramanspectroscopy
AT fenghaosun researchonchemicaloxygendemandbasedonlaserfluorescenceramanspectroscopy
AT qingcaoliu researchonchemicaloxygendemandbasedonlaserfluorescenceramanspectroscopy
AT zongjiebi researchonchemicaloxygendemandbasedonlaserfluorescenceramanspectroscopy
AT haochen researchonchemicaloxygendemandbasedonlaserfluorescenceramanspectroscopy
AT zihaocui researchonchemicaloxygendemandbasedonlaserfluorescenceramanspectroscopy