A helical charge simulation based 3-D calculation model for corona loss of AC stranded conductors in the corona cage

Corona loss generated from conductors is an indispensable factor in the design of alternating current(AC) transmission lines. Based on a helical charge simulation method, a 3-D calculation model for corona loss considering the outer strands of the conductor in the corona cage was established. Compar...

Full description

Bibliographic Details
Main Authors: Yunpeng Liu, Shilong Huang, Shugang Liu, Daran Liu
Format: Article
Language:English
Published: AIP Publishing LLC 2018-01-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/1.5017244
_version_ 1819143581180362752
author Yunpeng Liu
Shilong Huang
Shugang Liu
Daran Liu
author_facet Yunpeng Liu
Shilong Huang
Shugang Liu
Daran Liu
author_sort Yunpeng Liu
collection DOAJ
description Corona loss generated from conductors is an indispensable factor in the design of alternating current(AC) transmission lines. Based on a helical charge simulation method, a 3-D calculation model for corona loss considering the outer strands of the conductor in the corona cage was established. Compared to the 2-D corona-loss calculation method, the calculation model proposed in this study incorporates the heterogeneity of the electric fields strength along the axial direction of the stranded conductor. Furthermore, it was also able to calculate the corona loss when the conductor had sagged. The calculation results of the LGJ-300/40 and LGJ-400/35 in the small corona cage show close agreement with the measurement results indicating that the corona-loss calculation model was accurate. In addition, the corona loss of the bundle conductors 4 × LGJ720 with sag in the UHV corona cage was also analyzed.
first_indexed 2024-12-22T12:28:31Z
format Article
id doaj.art-9fd1ea0fa30c4241a0bd4fbdc7bb0af1
institution Directory Open Access Journal
issn 2158-3226
language English
last_indexed 2024-12-22T12:28:31Z
publishDate 2018-01-01
publisher AIP Publishing LLC
record_format Article
series AIP Advances
spelling doaj.art-9fd1ea0fa30c4241a0bd4fbdc7bb0af12022-12-21T18:25:42ZengAIP Publishing LLCAIP Advances2158-32262018-01-0181015303015303-1310.1063/1.5017244004801ADVA helical charge simulation based 3-D calculation model for corona loss of AC stranded conductors in the corona cageYunpeng Liu0Shilong Huang1Shugang Liu2Daran Liu3Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, ChinaHebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, ChinaHebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, ChinaHebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, ChinaCorona loss generated from conductors is an indispensable factor in the design of alternating current(AC) transmission lines. Based on a helical charge simulation method, a 3-D calculation model for corona loss considering the outer strands of the conductor in the corona cage was established. Compared to the 2-D corona-loss calculation method, the calculation model proposed in this study incorporates the heterogeneity of the electric fields strength along the axial direction of the stranded conductor. Furthermore, it was also able to calculate the corona loss when the conductor had sagged. The calculation results of the LGJ-300/40 and LGJ-400/35 in the small corona cage show close agreement with the measurement results indicating that the corona-loss calculation model was accurate. In addition, the corona loss of the bundle conductors 4 × LGJ720 with sag in the UHV corona cage was also analyzed.http://dx.doi.org/10.1063/1.5017244
spellingShingle Yunpeng Liu
Shilong Huang
Shugang Liu
Daran Liu
A helical charge simulation based 3-D calculation model for corona loss of AC stranded conductors in the corona cage
AIP Advances
title A helical charge simulation based 3-D calculation model for corona loss of AC stranded conductors in the corona cage
title_full A helical charge simulation based 3-D calculation model for corona loss of AC stranded conductors in the corona cage
title_fullStr A helical charge simulation based 3-D calculation model for corona loss of AC stranded conductors in the corona cage
title_full_unstemmed A helical charge simulation based 3-D calculation model for corona loss of AC stranded conductors in the corona cage
title_short A helical charge simulation based 3-D calculation model for corona loss of AC stranded conductors in the corona cage
title_sort helical charge simulation based 3 d calculation model for corona loss of ac stranded conductors in the corona cage
url http://dx.doi.org/10.1063/1.5017244
work_keys_str_mv AT yunpengliu ahelicalchargesimulationbased3dcalculationmodelforcoronalossofacstrandedconductorsinthecoronacage
AT shilonghuang ahelicalchargesimulationbased3dcalculationmodelforcoronalossofacstrandedconductorsinthecoronacage
AT shugangliu ahelicalchargesimulationbased3dcalculationmodelforcoronalossofacstrandedconductorsinthecoronacage
AT daranliu ahelicalchargesimulationbased3dcalculationmodelforcoronalossofacstrandedconductorsinthecoronacage
AT yunpengliu helicalchargesimulationbased3dcalculationmodelforcoronalossofacstrandedconductorsinthecoronacage
AT shilonghuang helicalchargesimulationbased3dcalculationmodelforcoronalossofacstrandedconductorsinthecoronacage
AT shugangliu helicalchargesimulationbased3dcalculationmodelforcoronalossofacstrandedconductorsinthecoronacage
AT daranliu helicalchargesimulationbased3dcalculationmodelforcoronalossofacstrandedconductorsinthecoronacage