Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, Abuja

Measurement of indoor and outdoor background ionising radiation level at Kwali General Hospital, Abuja, Nigeria was carried out using a well calibrated Geiger muller counter; Atomtex AT1117M radiation monitor. The dose equivalent results obtained range from 0.100±0.001 ìSv/h to 0.124±0.007 µSv/h wit...

Full description

Bibliographic Details
Main Authors: IU James, IF Moses, JN Vandi, UE Ikoh
Format: Article
Language:English
Published: Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP) 2015-05-01
Series:Journal of Applied Sciences and Environmental Management
Subjects:
Online Access:https://www.ajol.info/index.php/jasem/article/view/116653
_version_ 1797227783007502336
author IU James
IF Moses
JN Vandi
UE Ikoh
author_facet IU James
IF Moses
JN Vandi
UE Ikoh
author_sort IU James
collection DOAJ
description Measurement of indoor and outdoor background ionising radiation level at Kwali General Hospital, Abuja, Nigeria was carried out using a well calibrated Geiger muller counter; Atomtex AT1117M radiation monitor. The dose equivalent results obtained range from 0.100±0.001 ìSv/h to 0.124±0.007 µSv/h with an average of 0.107±0.003 ìSv/h for indoor measurement while it ranges from 0.100±0.001 µSv/h to 0.122±0.003 µSv/h with an average of 0.108±0.003 µSv/h for outdoor measurement respectively. The obtained values are below the standard background radiation of 0.133 µSv/h. The study also revealed that the average annual equivalent dose rate is 0.750± 0.020 mSv/y and 0.189±0.005 mSv/y for indoor and outdoor measurements respectively. These results revealed that the dose levels in all of the locations (indoor and outdoor) were below the 1 mSv/y maximum permissible limit for the public set by International Commission on Radiological Protection (ICRP). Therefore, Kwali General Hospital is radiologically safe ©JASEM
first_indexed 2024-04-24T14:46:17Z
format Article
id doaj.art-a0091f131ce048b3b0a1a714ccdf2241
institution Directory Open Access Journal
issn 2659-1502
2659-1499
language English
last_indexed 2024-04-24T14:46:17Z
publishDate 2015-05-01
publisher Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP)
record_format Article
series Journal of Applied Sciences and Environmental Management
spelling doaj.art-a0091f131ce048b3b0a1a714ccdf22412024-04-02T19:56:15ZengJoint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP)Journal of Applied Sciences and Environmental Management2659-15022659-14992015-05-0119110.4314/jasem.v19i1.12Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, AbujaIU JamesIF MosesJN VandiUE IkohMeasurement of indoor and outdoor background ionising radiation level at Kwali General Hospital, Abuja, Nigeria was carried out using a well calibrated Geiger muller counter; Atomtex AT1117M radiation monitor. The dose equivalent results obtained range from 0.100±0.001 ìSv/h to 0.124±0.007 µSv/h with an average of 0.107±0.003 ìSv/h for indoor measurement while it ranges from 0.100±0.001 µSv/h to 0.122±0.003 µSv/h with an average of 0.108±0.003 µSv/h for outdoor measurement respectively. The obtained values are below the standard background radiation of 0.133 µSv/h. The study also revealed that the average annual equivalent dose rate is 0.750± 0.020 mSv/y and 0.189±0.005 mSv/y for indoor and outdoor measurements respectively. These results revealed that the dose levels in all of the locations (indoor and outdoor) were below the 1 mSv/y maximum permissible limit for the public set by International Commission on Radiological Protection (ICRP). Therefore, Kwali General Hospital is radiologically safe ©JASEMhttps://www.ajol.info/index.php/jasem/article/view/116653Background ionising radiationGeiger muller counterradiation monitorequivalent doseindoor and outdoor measurement
spellingShingle IU James
IF Moses
JN Vandi
UE Ikoh
Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, Abuja
Journal of Applied Sciences and Environmental Management
Background ionising radiation
Geiger muller counter
radiation monitor
equivalent dose
indoor and outdoor measurement
title Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, Abuja
title_full Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, Abuja
title_fullStr Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, Abuja
title_full_unstemmed Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, Abuja
title_short Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, Abuja
title_sort measurement of indoor and outdoor background ionising radiation levels of kwali general hospital abuja
topic Background ionising radiation
Geiger muller counter
radiation monitor
equivalent dose
indoor and outdoor measurement
url https://www.ajol.info/index.php/jasem/article/view/116653
work_keys_str_mv AT iujames measurementofindoorandoutdoorbackgroundionisingradiationlevelsofkwaligeneralhospitalabuja
AT ifmoses measurementofindoorandoutdoorbackgroundionisingradiationlevelsofkwaligeneralhospitalabuja
AT jnvandi measurementofindoorandoutdoorbackgroundionisingradiationlevelsofkwaligeneralhospitalabuja
AT ueikoh measurementofindoorandoutdoorbackgroundionisingradiationlevelsofkwaligeneralhospitalabuja