Recommendations and good practices for dissolved organic carbon (DOC) analyses at low concentrations

Numerous protocols for dissolved organic carbon (DOC) measurements on natural water are used in the literature. An ISO protocol for the determination of DOC exists since 2018, but it is certified for DOC values ≥ 1 mg L−1, while many publications report DOC values much lower. In addition, this ISO p...

Full description

Bibliographic Details
Main Authors: Delphine Tisserand, Damien Daval, Laurent Truche, Alejandro Fernandez-Martinez, Géraldine Sarret, Lorenzo Spadini, Julien Némery
Format: Article
Language:English
Published: Elsevier 2024-06-01
Series:MethodsX
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2215016124001171
_version_ 1797246808439652352
author Delphine Tisserand
Damien Daval
Laurent Truche
Alejandro Fernandez-Martinez
Géraldine Sarret
Lorenzo Spadini
Julien Némery
author_facet Delphine Tisserand
Damien Daval
Laurent Truche
Alejandro Fernandez-Martinez
Géraldine Sarret
Lorenzo Spadini
Julien Némery
author_sort Delphine Tisserand
collection DOAJ
description Numerous protocols for dissolved organic carbon (DOC) measurements on natural water are used in the literature. An ISO protocol for the determination of DOC exists since 2018, but it is certified for DOC values ≥ 1 mg L−1, while many publications report DOC values much lower. In addition, this ISO protocol does not include indications on vials cleaning, filtering material, and type of caps and septa to be used. The purpose of this study was to evaluate protocols for measurements of low DOC concentrations (≤ 1 mg L−1). The effect of the sample container, type of septum, filtration material, nature of acid used for storage, and matrix effects on DOC concentration were evaluated. • The use of glass vials decontaminated at 450 °C or 500 °C for at least 1 h, 0.45 µm hydrophilic polytetrafluoroethylene (PTFE) membranes previously rinsed with 20 mL ultra-pure water and HCl acidification gives the lowest DOC contamination, • Sulfides (ΣH2S), sodium (Na+) or calcium (Ca2+) do not induce high matrix effect for the analysis (≤ 10%), • At low DOC concentrations (≤ 1 mg L−1), the use of pierced PTFE septa with acidified samples induce slight DOC contamination after storage at 4 °C, and dramatic contamination after storage at -18 °C.
first_indexed 2024-04-24T19:48:41Z
format Article
id doaj.art-a06967df1a0f43c3b503fd64dcef90c2
institution Directory Open Access Journal
issn 2215-0161
language English
last_indexed 2024-04-24T19:48:41Z
publishDate 2024-06-01
publisher Elsevier
record_format Article
series MethodsX
spelling doaj.art-a06967df1a0f43c3b503fd64dcef90c22024-03-25T04:17:49ZengElsevierMethodsX2215-01612024-06-0112102663Recommendations and good practices for dissolved organic carbon (DOC) analyses at low concentrationsDelphine Tisserand0Damien Daval1Laurent Truche2Alejandro Fernandez-Martinez3Géraldine Sarret4Lorenzo Spadini5Julien Némery6CNRS, IRD, Univ. Gustave Eiffel, ISTerre, Université Grenoble Alpes, Université Savoie Mont Blanc, Grenoble 38000, France; Corresponding author.CNRS, IRD, Univ. Gustave Eiffel, ISTerre, Université Grenoble Alpes, Université Savoie Mont Blanc, Grenoble 38000, FranceCNRS, IRD, Univ. Gustave Eiffel, ISTerre, Université Grenoble Alpes, Université Savoie Mont Blanc, Grenoble 38000, FranceCNRS, IRD, Univ. Gustave Eiffel, ISTerre, Université Grenoble Alpes, Université Savoie Mont Blanc, Grenoble 38000, FranceCNRS, IRD, Univ. Gustave Eiffel, ISTerre, Université Grenoble Alpes, Université Savoie Mont Blanc, Grenoble 38000, FranceUniv. Grenoble Alpes, CNRS, IRD, INRAE, Grenoble INP (Institute of Engineering), IGE, F-38000 Grenoble, FranceUniv. Grenoble Alpes, CNRS, IRD, INRAE, Grenoble INP (Institute of Engineering), IGE, F-38000 Grenoble, FranceNumerous protocols for dissolved organic carbon (DOC) measurements on natural water are used in the literature. An ISO protocol for the determination of DOC exists since 2018, but it is certified for DOC values ≥ 1 mg L−1, while many publications report DOC values much lower. In addition, this ISO protocol does not include indications on vials cleaning, filtering material, and type of caps and septa to be used. The purpose of this study was to evaluate protocols for measurements of low DOC concentrations (≤ 1 mg L−1). The effect of the sample container, type of septum, filtration material, nature of acid used for storage, and matrix effects on DOC concentration were evaluated. • The use of glass vials decontaminated at 450 °C or 500 °C for at least 1 h, 0.45 µm hydrophilic polytetrafluoroethylene (PTFE) membranes previously rinsed with 20 mL ultra-pure water and HCl acidification gives the lowest DOC contamination, • Sulfides (ΣH2S), sodium (Na+) or calcium (Ca2+) do not induce high matrix effect for the analysis (≤ 10%), • At low DOC concentrations (≤ 1 mg L−1), the use of pierced PTFE septa with acidified samples induce slight DOC contamination after storage at 4 °C, and dramatic contamination after storage at -18 °C.http://www.sciencedirect.com/science/article/pii/S2215016124001171Vial typesFiltrationAcidificationStorage conditionsPierced septa
spellingShingle Delphine Tisserand
Damien Daval
Laurent Truche
Alejandro Fernandez-Martinez
Géraldine Sarret
Lorenzo Spadini
Julien Némery
Recommendations and good practices for dissolved organic carbon (DOC) analyses at low concentrations
MethodsX
Vial types
Filtration
Acidification
Storage conditions
Pierced septa
title Recommendations and good practices for dissolved organic carbon (DOC) analyses at low concentrations
title_full Recommendations and good practices for dissolved organic carbon (DOC) analyses at low concentrations
title_fullStr Recommendations and good practices for dissolved organic carbon (DOC) analyses at low concentrations
title_full_unstemmed Recommendations and good practices for dissolved organic carbon (DOC) analyses at low concentrations
title_short Recommendations and good practices for dissolved organic carbon (DOC) analyses at low concentrations
title_sort recommendations and good practices for dissolved organic carbon doc analyses at low concentrations
topic Vial types
Filtration
Acidification
Storage conditions
Pierced septa
url http://www.sciencedirect.com/science/article/pii/S2215016124001171
work_keys_str_mv AT delphinetisserand recommendationsandgoodpracticesfordissolvedorganiccarbondocanalysesatlowconcentrations
AT damiendaval recommendationsandgoodpracticesfordissolvedorganiccarbondocanalysesatlowconcentrations
AT laurenttruche recommendationsandgoodpracticesfordissolvedorganiccarbondocanalysesatlowconcentrations
AT alejandrofernandezmartinez recommendationsandgoodpracticesfordissolvedorganiccarbondocanalysesatlowconcentrations
AT geraldinesarret recommendationsandgoodpracticesfordissolvedorganiccarbondocanalysesatlowconcentrations
AT lorenzospadini recommendationsandgoodpracticesfordissolvedorganiccarbondocanalysesatlowconcentrations
AT juliennemery recommendationsandgoodpracticesfordissolvedorganiccarbondocanalysesatlowconcentrations