Evaluation of True Ankle Motion Following Total Ankle Replacement Utilizing XROMM technology

Category: Ankle Arthritis Introduction/Purpose: Total ankle replacement (TAR) is common tool used by the foot and ankle specialist to treat end stage ankle arthritis. Current data about ankle motion following TAR is derived from gait analysis utilizing external markers. Utilizing Xray Reconstruction...

Full description

Bibliographic Details
Main Authors: Emily M. Abbott, Zoe Merchant, Erica Lee, Sadie M. Abernathy, Charles Hammer, Young-Hui Chang, Jason T. Bariteau MD
Format: Article
Language:English
Published: SAGE Publishing 2020-10-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011420S00017
_version_ 1819205876000489472
author Emily M. Abbott
Zoe Merchant
Erica Lee
Sadie M. Abernathy
Charles Hammer
Young-Hui Chang
Jason T. Bariteau MD
author_facet Emily M. Abbott
Zoe Merchant
Erica Lee
Sadie M. Abernathy
Charles Hammer
Young-Hui Chang
Jason T. Bariteau MD
author_sort Emily M. Abbott
collection DOAJ
description Category: Ankle Arthritis Introduction/Purpose: Total ankle replacement (TAR) is common tool used by the foot and ankle specialist to treat end stage ankle arthritis. Current data about ankle motion following TAR is derived from gait analysis utilizing external markers. Utilizing Xray Reconstruction of Moving Morphology (XROMM), which combines 3-D mapping technology with biplanar fluoroscopy in vivo to visualize true skeletal motion, we can evaluate true motion of TAR implants. Current TAR replacement systems are either mobile bearing or fixed bearing. We hypothesized that subjects implanted with a fixed bearing prosthesis would exhibit less tibiotalar rotation and translation than subjects implanted with a mobile bearing prosthesis. Methods: Six subjects with total ankle replacement at least one-year post implantation gave informed consent before participating (IRB #H16496). Three subjects with a mobile bearing prosthesis with an average age 63.3+-11.1 yrs were compared to three matched subjects with a fixed bearing prosthesis with an average age of 64.7+-1.5 yrs. Utilizing 3D slicer software, lower body CT scans for each subject were evaluated to create 3D models of the foot and ankle bones and implant components. All subjects walked for several trials at a self-selected pace along a walkway while their foot and ankle motions were captured by a high-speed biplanar fluoroscopic x-ray motion analysis (XMA) system. The 3D models were combined with the x-ray images within a 3D animation platform and rotoscoped to resolve accurate kinematic motions at the tibiotalar joint during stance phase of gait. We examined for differences between the two groups using a two-sample t-test (p<0.05). Results: Subjects with a mobile-bearing prosthesis demonstrated mean ROM’s of 7.4+-1.1°, 5.3+-2.3° and 7.1+-4.3° for dorsiflexion/plantarflexion, inversion/eversion, and internal/external rotation, respectively. Subjects with a fixed bearing ankle prosthesis did not exhibit significantly different mean ROM’s for dorsiflexion/plantarflexion (9.1+-4.0°, p=0.35), inversion/eversion (4.4+-2.1°, p=0.42), and internal/external rotation (9.0+-3.4°, p=0.35), respectively. Subjects with a fixed bearing prosthesis displayed significantly more translation along the anteroposterior (3.6+-1.2mm, p<0.01) and mediolateral (2.2+-0.7mm, p<0.01) axes compared to the mobile bearing prosthesis (1.8+-1.2mm and 1.3+-0.8mm, respectively). Conclusion: Our preliminary results indicate that mobile and fixed bearing prosthesis provides similar angular motion at the tibiotalar joint, however, the fixed bearing prosthesis exhibits greater translational motion during walking. Further, there is the same amount of internal and external translation with both component designs. The implications of this work on success or failure of current implant designs is beyond the scope of this study but this work will provide the basis for future studies to help determine optimal future total ankle replacement designs.
first_indexed 2024-12-23T04:58:40Z
format Article
id doaj.art-a06c44ff3537405d90a725dd446f4bda
institution Directory Open Access Journal
issn 2473-0114
language English
last_indexed 2024-12-23T04:58:40Z
publishDate 2020-10-01
publisher SAGE Publishing
record_format Article
series Foot & Ankle Orthopaedics
spelling doaj.art-a06c44ff3537405d90a725dd446f4bda2022-12-21T17:59:17ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142020-10-01510.1177/2473011420S00017Evaluation of True Ankle Motion Following Total Ankle Replacement Utilizing XROMM technologyEmily M. AbbottZoe MerchantErica LeeSadie M. AbernathyCharles HammerYoung-Hui ChangJason T. Bariteau MDCategory: Ankle Arthritis Introduction/Purpose: Total ankle replacement (TAR) is common tool used by the foot and ankle specialist to treat end stage ankle arthritis. Current data about ankle motion following TAR is derived from gait analysis utilizing external markers. Utilizing Xray Reconstruction of Moving Morphology (XROMM), which combines 3-D mapping technology with biplanar fluoroscopy in vivo to visualize true skeletal motion, we can evaluate true motion of TAR implants. Current TAR replacement systems are either mobile bearing or fixed bearing. We hypothesized that subjects implanted with a fixed bearing prosthesis would exhibit less tibiotalar rotation and translation than subjects implanted with a mobile bearing prosthesis. Methods: Six subjects with total ankle replacement at least one-year post implantation gave informed consent before participating (IRB #H16496). Three subjects with a mobile bearing prosthesis with an average age 63.3+-11.1 yrs were compared to three matched subjects with a fixed bearing prosthesis with an average age of 64.7+-1.5 yrs. Utilizing 3D slicer software, lower body CT scans for each subject were evaluated to create 3D models of the foot and ankle bones and implant components. All subjects walked for several trials at a self-selected pace along a walkway while their foot and ankle motions were captured by a high-speed biplanar fluoroscopic x-ray motion analysis (XMA) system. The 3D models were combined with the x-ray images within a 3D animation platform and rotoscoped to resolve accurate kinematic motions at the tibiotalar joint during stance phase of gait. We examined for differences between the two groups using a two-sample t-test (p<0.05). Results: Subjects with a mobile-bearing prosthesis demonstrated mean ROM’s of 7.4+-1.1°, 5.3+-2.3° and 7.1+-4.3° for dorsiflexion/plantarflexion, inversion/eversion, and internal/external rotation, respectively. Subjects with a fixed bearing ankle prosthesis did not exhibit significantly different mean ROM’s for dorsiflexion/plantarflexion (9.1+-4.0°, p=0.35), inversion/eversion (4.4+-2.1°, p=0.42), and internal/external rotation (9.0+-3.4°, p=0.35), respectively. Subjects with a fixed bearing prosthesis displayed significantly more translation along the anteroposterior (3.6+-1.2mm, p<0.01) and mediolateral (2.2+-0.7mm, p<0.01) axes compared to the mobile bearing prosthesis (1.8+-1.2mm and 1.3+-0.8mm, respectively). Conclusion: Our preliminary results indicate that mobile and fixed bearing prosthesis provides similar angular motion at the tibiotalar joint, however, the fixed bearing prosthesis exhibits greater translational motion during walking. Further, there is the same amount of internal and external translation with both component designs. The implications of this work on success or failure of current implant designs is beyond the scope of this study but this work will provide the basis for future studies to help determine optimal future total ankle replacement designs.https://doi.org/10.1177/2473011420S00017
spellingShingle Emily M. Abbott
Zoe Merchant
Erica Lee
Sadie M. Abernathy
Charles Hammer
Young-Hui Chang
Jason T. Bariteau MD
Evaluation of True Ankle Motion Following Total Ankle Replacement Utilizing XROMM technology
Foot & Ankle Orthopaedics
title Evaluation of True Ankle Motion Following Total Ankle Replacement Utilizing XROMM technology
title_full Evaluation of True Ankle Motion Following Total Ankle Replacement Utilizing XROMM technology
title_fullStr Evaluation of True Ankle Motion Following Total Ankle Replacement Utilizing XROMM technology
title_full_unstemmed Evaluation of True Ankle Motion Following Total Ankle Replacement Utilizing XROMM technology
title_short Evaluation of True Ankle Motion Following Total Ankle Replacement Utilizing XROMM technology
title_sort evaluation of true ankle motion following total ankle replacement utilizing xromm technology
url https://doi.org/10.1177/2473011420S00017
work_keys_str_mv AT emilymabbott evaluationoftrueanklemotionfollowingtotalanklereplacementutilizingxrommtechnology
AT zoemerchant evaluationoftrueanklemotionfollowingtotalanklereplacementutilizingxrommtechnology
AT ericalee evaluationoftrueanklemotionfollowingtotalanklereplacementutilizingxrommtechnology
AT sadiemabernathy evaluationoftrueanklemotionfollowingtotalanklereplacementutilizingxrommtechnology
AT charleshammer evaluationoftrueanklemotionfollowingtotalanklereplacementutilizingxrommtechnology
AT younghuichang evaluationoftrueanklemotionfollowingtotalanklereplacementutilizingxrommtechnology
AT jasontbariteaumd evaluationoftrueanklemotionfollowingtotalanklereplacementutilizingxrommtechnology