Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children – A prospective randomized controlled trial

Background and Aims: Truview evo2 has been found to improve the glottic view when compared with the Miller blade in pediatric population. However, there is limited literature comparing it with Macintosh laryngoscope in children. We thus aimed to assess and compare Truview evo2 with the Macintosh lar...

Full description

Bibliographic Details
Main Authors: Neha Pangasa, Jaspal Singh Dali, Kavita Rani Sharma, Mona Arya, Anant Vikram Pachisia
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Journal of Anaesthesiology Clinical Pharmacology
Subjects:
Online Access:http://www.joacp.org/article.asp?issn=0970-9185;year=2019;volume=35;issue=1;spage=25;epage=29;aulast=Pangasa
_version_ 1828425922511896576
author Neha Pangasa
Jaspal Singh Dali
Kavita Rani Sharma
Mona Arya
Anant Vikram Pachisia
author_facet Neha Pangasa
Jaspal Singh Dali
Kavita Rani Sharma
Mona Arya
Anant Vikram Pachisia
author_sort Neha Pangasa
collection DOAJ
description Background and Aims: Truview evo2 has been found to improve the glottic view when compared with the Miller blade in pediatric population. However, there is limited literature comparing it with Macintosh laryngoscope in children. We thus aimed to assess and compare Truview evo2 with the Macintosh laryngoscope for orotracheal intubation in children with regards to time to intubate, laryngoscopic view, ease of intubation, and associated hemodynamic changes. Material and Methods: Fifty ASA I-II children aged 2–8 years for elective surgery requiring general anesthesia with orotracheal intubation participated in this prospective randomized-controlled study. They were randomly allocated to two groups. In group-M (N = 25), laryngoscopy and intubation were performed using Macintosh laryngoscope, and in group-T (N = 25), Truview evo2 laryngoscope was used. Modified Cormack–Lehane grade, time to intubation, intubation difficulty score (IDS), and hemodynamic changes were compared between the groups. Data were analyzed using SPSS statistical software version 17 and P value <0.05 was considered statistically significant. Results: CL grade 1 was found in a larger number of patients of group-T (P = 0.003) and CL grades2a and 2b were found in a larger number of patients of group-M (P = 0.023 and P = 0.037, respectively). The mean time to intubation was significantly longer in group-T (19.0 ± 3.4 seconds) than in group-M (13.1 ± 2.1 seconds), P = 0.00. The over all IDS was lower in group-T than group M [i.e. median (IQR): 0 (0-0) vs 1 (0-2), respectively]. Heart rate, systolic and diastolic blood pressure, and oxygen saturation were comparable between the groups at all times. Conclusion: Truview evo2 provides better laryngeal view and has a lesser IDS, but takes longer for intubation, when compared to the Macintosh laryngoscope in children.
first_indexed 2024-12-10T16:38:35Z
format Article
id doaj.art-a0d1bcddba454d018553c64d134c8f91
institution Directory Open Access Journal
issn 0970-9185
language English
last_indexed 2024-12-10T16:38:35Z
publishDate 2019-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Anaesthesiology Clinical Pharmacology
spelling doaj.art-a0d1bcddba454d018553c64d134c8f912022-12-22T01:41:18ZengWolters Kluwer Medknow PublicationsJournal of Anaesthesiology Clinical Pharmacology0970-91852019-01-01351252910.4103/joacp.JOACP_118_18Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children – A prospective randomized controlled trialNeha PangasaJaspal Singh DaliKavita Rani SharmaMona AryaAnant Vikram PachisiaBackground and Aims: Truview evo2 has been found to improve the glottic view when compared with the Miller blade in pediatric population. However, there is limited literature comparing it with Macintosh laryngoscope in children. We thus aimed to assess and compare Truview evo2 with the Macintosh laryngoscope for orotracheal intubation in children with regards to time to intubate, laryngoscopic view, ease of intubation, and associated hemodynamic changes. Material and Methods: Fifty ASA I-II children aged 2–8 years for elective surgery requiring general anesthesia with orotracheal intubation participated in this prospective randomized-controlled study. They were randomly allocated to two groups. In group-M (N = 25), laryngoscopy and intubation were performed using Macintosh laryngoscope, and in group-T (N = 25), Truview evo2 laryngoscope was used. Modified Cormack–Lehane grade, time to intubation, intubation difficulty score (IDS), and hemodynamic changes were compared between the groups. Data were analyzed using SPSS statistical software version 17 and P value <0.05 was considered statistically significant. Results: CL grade 1 was found in a larger number of patients of group-T (P = 0.003) and CL grades2a and 2b were found in a larger number of patients of group-M (P = 0.023 and P = 0.037, respectively). The mean time to intubation was significantly longer in group-T (19.0 ± 3.4 seconds) than in group-M (13.1 ± 2.1 seconds), P = 0.00. The over all IDS was lower in group-T than group M [i.e. median (IQR): 0 (0-0) vs 1 (0-2), respectively]. Heart rate, systolic and diastolic blood pressure, and oxygen saturation were comparable between the groups at all times. Conclusion: Truview evo2 provides better laryngeal view and has a lesser IDS, but takes longer for intubation, when compared to the Macintosh laryngoscope in children.http://www.joacp.org/article.asp?issn=0970-9185;year=2019;volume=35;issue=1;spage=25;epage=29;aulast=PangasaCL gradeMacintoshtime to intubationTruview evo2
spellingShingle Neha Pangasa
Jaspal Singh Dali
Kavita Rani Sharma
Mona Arya
Anant Vikram Pachisia
Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children – A prospective randomized controlled trial
Journal of Anaesthesiology Clinical Pharmacology
CL grade
Macintosh
time to intubation
Truview evo2
title Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children – A prospective randomized controlled trial
title_full Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children – A prospective randomized controlled trial
title_fullStr Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children – A prospective randomized controlled trial
title_full_unstemmed Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children – A prospective randomized controlled trial
title_short Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children – A prospective randomized controlled trial
title_sort comparative evaluation of truview evo2 and macintosh laryngoscope for ease of orotracheal intubation in children a prospective randomized controlled trial
topic CL grade
Macintosh
time to intubation
Truview evo2
url http://www.joacp.org/article.asp?issn=0970-9185;year=2019;volume=35;issue=1;spage=25;epage=29;aulast=Pangasa
work_keys_str_mv AT nehapangasa comparativeevaluationoftruviewevo2andmacintoshlaryngoscopeforeaseoforotrachealintubationinchildrenaprospectiverandomizedcontrolledtrial
AT jaspalsinghdali comparativeevaluationoftruviewevo2andmacintoshlaryngoscopeforeaseoforotrachealintubationinchildrenaprospectiverandomizedcontrolledtrial
AT kavitaranisharma comparativeevaluationoftruviewevo2andmacintoshlaryngoscopeforeaseoforotrachealintubationinchildrenaprospectiverandomizedcontrolledtrial
AT monaarya comparativeevaluationoftruviewevo2andmacintoshlaryngoscopeforeaseoforotrachealintubationinchildrenaprospectiverandomizedcontrolledtrial
AT anantvikrampachisia comparativeevaluationoftruviewevo2andmacintoshlaryngoscopeforeaseoforotrachealintubationinchildrenaprospectiverandomizedcontrolledtrial