A New Impedance-Based Main and Backup Protection Scheme for Active Distribution Lines in AC Microgrids

Microgrids active characteristics such as grid-connected or islanded operation mode, the distributed generators with an intermittent nature, and bidirectional power flow in active distribution lines lead to malfunction of traditional protection schemes. In this article, an impedance-based fault dete...

Full description

Bibliographic Details
Main Authors: Seyyed Mohammad Nobakhti, Abbas Ketabi, Miadreza Shafie-khah
Format: Article
Language:English
Published: MDPI AG 2021-01-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/2/274
_version_ 1797415992754700288
author Seyyed Mohammad Nobakhti
Abbas Ketabi
Miadreza Shafie-khah
author_facet Seyyed Mohammad Nobakhti
Abbas Ketabi
Miadreza Shafie-khah
author_sort Seyyed Mohammad Nobakhti
collection DOAJ
description Microgrids active characteristics such as grid-connected or islanded operation mode, the distributed generators with an intermittent nature, and bidirectional power flow in active distribution lines lead to malfunction of traditional protection schemes. In this article, an impedance-based fault detection scheme is proposed as the main protection of microgrids by applying the proposed equivalent circuits for doubly-fed lines. In this scheme, relay location data and positive sequence voltage absolute value of the other end of the line are used. It can detect even high impedance faults in grid-connected and islanded modes. It is robust against load and generation uncertainties and network reconfigurations. Low sampling rate and minimum data exchange are among the advantages of the proposed scheme. Moreover, a backup protection scheme based on the conductance variations is suggested. No requirement for the communication link is a distinguished advantage of the proposed backup protection scheme. The proposed schemes have been simulated using PSCAD and MATLAB software and the results confirmed their validity.
first_indexed 2024-03-09T05:57:28Z
format Article
id doaj.art-a14543996c1449e9b7de97916ed16fe2
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-09T05:57:28Z
publishDate 2021-01-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-a14543996c1449e9b7de97916ed16fe22023-12-03T12:12:38ZengMDPI AGEnergies1996-10732021-01-0114227410.3390/en14020274A New Impedance-Based Main and Backup Protection Scheme for Active Distribution Lines in AC MicrogridsSeyyed Mohammad Nobakhti0Abbas Ketabi1Miadreza Shafie-khah2Department of Electrical and Computer Engineering, University of Kashan, Kashan 8731753153, IranDepartment of Electrical and Computer Engineering, University of Kashan, Kashan 8731753153, IranSchool of Technology and Innovations, University of Vaasa, 65200 Vaasa, FinlandMicrogrids active characteristics such as grid-connected or islanded operation mode, the distributed generators with an intermittent nature, and bidirectional power flow in active distribution lines lead to malfunction of traditional protection schemes. In this article, an impedance-based fault detection scheme is proposed as the main protection of microgrids by applying the proposed equivalent circuits for doubly-fed lines. In this scheme, relay location data and positive sequence voltage absolute value of the other end of the line are used. It can detect even high impedance faults in grid-connected and islanded modes. It is robust against load and generation uncertainties and network reconfigurations. Low sampling rate and minimum data exchange are among the advantages of the proposed scheme. Moreover, a backup protection scheme based on the conductance variations is suggested. No requirement for the communication link is a distinguished advantage of the proposed backup protection scheme. The proposed schemes have been simulated using PSCAD and MATLAB software and the results confirmed their validity.https://www.mdpi.com/1996-1073/14/2/274backup protectiondistributed generationdistribution networkfault detectionimpedance-based protectionmain protection
spellingShingle Seyyed Mohammad Nobakhti
Abbas Ketabi
Miadreza Shafie-khah
A New Impedance-Based Main and Backup Protection Scheme for Active Distribution Lines in AC Microgrids
Energies
backup protection
distributed generation
distribution network
fault detection
impedance-based protection
main protection
title A New Impedance-Based Main and Backup Protection Scheme for Active Distribution Lines in AC Microgrids
title_full A New Impedance-Based Main and Backup Protection Scheme for Active Distribution Lines in AC Microgrids
title_fullStr A New Impedance-Based Main and Backup Protection Scheme for Active Distribution Lines in AC Microgrids
title_full_unstemmed A New Impedance-Based Main and Backup Protection Scheme for Active Distribution Lines in AC Microgrids
title_short A New Impedance-Based Main and Backup Protection Scheme for Active Distribution Lines in AC Microgrids
title_sort new impedance based main and backup protection scheme for active distribution lines in ac microgrids
topic backup protection
distributed generation
distribution network
fault detection
impedance-based protection
main protection
url https://www.mdpi.com/1996-1073/14/2/274
work_keys_str_mv AT seyyedmohammadnobakhti anewimpedancebasedmainandbackupprotectionschemeforactivedistributionlinesinacmicrogrids
AT abbasketabi anewimpedancebasedmainandbackupprotectionschemeforactivedistributionlinesinacmicrogrids
AT miadrezashafiekhah anewimpedancebasedmainandbackupprotectionschemeforactivedistributionlinesinacmicrogrids
AT seyyedmohammadnobakhti newimpedancebasedmainandbackupprotectionschemeforactivedistributionlinesinacmicrogrids
AT abbasketabi newimpedancebasedmainandbackupprotectionschemeforactivedistributionlinesinacmicrogrids
AT miadrezashafiekhah newimpedancebasedmainandbackupprotectionschemeforactivedistributionlinesinacmicrogrids