A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect
For investigating the relationship between the surface corona discharge of a DC wire and other influencing factors, a hybrid numerical model based on a fluid-chemical reaction was proposed to simulate the discharge process at the tip defect of the wire. Under different defect geometries and gas pres...
Váldodahkkit: | , , |
---|---|
Materiálatiipa: | Artihkal |
Giella: | English |
Almmustuhtton: |
MDPI AG
2023-09-01
|
Ráidu: | Applied Sciences |
Fáttát: | |
Liŋkkat: | https://www.mdpi.com/2076-3417/13/18/10472 |
_version_ | 1827727314835734528 |
---|---|
author | Shenghui Wang Jiamin Mai Lihong Wang |
author_facet | Shenghui Wang Jiamin Mai Lihong Wang |
author_sort | Shenghui Wang |
collection | DOAJ |
description | For investigating the relationship between the surface corona discharge of a DC wire and other influencing factors, a hybrid numerical model based on a fluid-chemical reaction was proposed to simulate the discharge process at the tip defect of the wire. Under different defect geometries and gas pressures achieved via simulation, the microscopic process of the reaction and movement of electrons and heavy particles during a positive corona discharge was studied, and characteristic parameters such as corona inception voltage and discharge current were analyzed. Furthermore, through the corona cage test, for a specific electrode configuration, corona inception voltages under different pressures were compared and verified, which showed that the model was reasonable. The results showed that the maximum electron density of the streamer head was about 1 × 10<sup>20</sup> m<sup>−3</sup>, the rise time of the pulse current was about 10 ns, and the decay time was about 300–500 ns. The corona inception voltage decreased with an increase in the tip height and decreases in the tip curvature radius, conductor radius, and background air pressure; the amplitude of the pulse current increased with increases in the wire radius and curvature radius of the defect tip and decreases in tip height and background air pressure. The experimental results are consistent with the simulation results, which verifies the reasonability of the model. |
first_indexed | 2024-03-10T23:03:44Z |
format | Article |
id | doaj.art-a185555bef0f47c1a02a464b8db83508 |
institution | Directory Open Access Journal |
issn | 2076-3417 |
language | English |
last_indexed | 2024-03-10T23:03:44Z |
publishDate | 2023-09-01 |
publisher | MDPI AG |
record_format | Article |
series | Applied Sciences |
spelling | doaj.art-a185555bef0f47c1a02a464b8db835082023-11-19T09:28:13ZengMDPI AGApplied Sciences2076-34172023-09-0113181047210.3390/app131810472A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip DefectShenghui Wang0Jiamin Mai1Lihong Wang2State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing 102206, ChinaDepartment of Computer Application Technology, Huazhong Electric Power Union Staff University, Wuhan 430014, ChinaFor investigating the relationship between the surface corona discharge of a DC wire and other influencing factors, a hybrid numerical model based on a fluid-chemical reaction was proposed to simulate the discharge process at the tip defect of the wire. Under different defect geometries and gas pressures achieved via simulation, the microscopic process of the reaction and movement of electrons and heavy particles during a positive corona discharge was studied, and characteristic parameters such as corona inception voltage and discharge current were analyzed. Furthermore, through the corona cage test, for a specific electrode configuration, corona inception voltages under different pressures were compared and verified, which showed that the model was reasonable. The results showed that the maximum electron density of the streamer head was about 1 × 10<sup>20</sup> m<sup>−3</sup>, the rise time of the pulse current was about 10 ns, and the decay time was about 300–500 ns. The corona inception voltage decreased with an increase in the tip height and decreases in the tip curvature radius, conductor radius, and background air pressure; the amplitude of the pulse current increased with increases in the wire radius and curvature radius of the defect tip and decreases in tip height and background air pressure. The experimental results are consistent with the simulation results, which verifies the reasonability of the model.https://www.mdpi.com/2076-3417/13/18/10472DC overhead linefluid-chemical modelcorona dischargetip defect |
spellingShingle | Shenghui Wang Jiamin Mai Lihong Wang A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect Applied Sciences DC overhead line fluid-chemical model corona discharge tip defect |
title | A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect |
title_full | A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect |
title_fullStr | A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect |
title_full_unstemmed | A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect |
title_short | A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect |
title_sort | numerical simulation study on dc positive corona discharge characteristics at the conductor s tip defect |
topic | DC overhead line fluid-chemical model corona discharge tip defect |
url | https://www.mdpi.com/2076-3417/13/18/10472 |
work_keys_str_mv | AT shenghuiwang anumericalsimulationstudyondcpositivecoronadischargecharacteristicsattheconductorstipdefect AT jiaminmai anumericalsimulationstudyondcpositivecoronadischargecharacteristicsattheconductorstipdefect AT lihongwang anumericalsimulationstudyondcpositivecoronadischargecharacteristicsattheconductorstipdefect AT shenghuiwang numericalsimulationstudyondcpositivecoronadischargecharacteristicsattheconductorstipdefect AT jiaminmai numericalsimulationstudyondcpositivecoronadischargecharacteristicsattheconductorstipdefect AT lihongwang numericalsimulationstudyondcpositivecoronadischargecharacteristicsattheconductorstipdefect |